Effect of Zero-Sequence Voltage on the Maximum Average Neutral-Point Current Limit of Neutral-Point-Clamped Converters

Author(s):  
Neha Beniwal ◽  
Glen G. Farivar ◽  
Salvador Ceballos ◽  
Naga Brahmendra Yadav Gorla ◽  
Josep Pou
2015 ◽  
Vol 2015 ◽  
pp. 1-12 ◽  
Author(s):  
Yingjie Wang ◽  
Haiyuan Liu ◽  
Wenchao Wang ◽  
Kangan Wang

The neutral-point (NP) potential balance control in three-level neutral-point-clamped (NPC) back-to-back converter is a research nodus. Its current strategies are the same as the strategies of a single three-level NPC converter. But the strategies do not give full play to its advantages that the neutral-point current can only flow through the connected midlines in both sides of the converter but does not flow through the DC-bus capacitors. In this paper, firstly the NP potential model based on the NP current injected is proposed. It overcomes numerous variable constraints and mutual coupling in the conventional model based on the zero-sequence voltage injected. And then on this basis, three NP-potential balance control algorithms, unilateral control, bilateral independent control, and bilateral coordinated control, are proposed according to difference requirements. All of these algorithms use the midlines rather than the DC-bus capacitors to flow the NP current as much as possible. Their control abilities are further quantitatively analyzed and compared. Finally, simulation results verify the validity and effectiveness of these algorithms.


Electronics ◽  
2019 ◽  
Vol 8 (6) ◽  
pp. 691 ◽  
Author(s):  
Ju-Yong Kim ◽  
Ho-Sung Kim ◽  
Ju-Won Baek ◽  
Dong-Keun Jeong

Low-voltage direct current (LVDC) distribution has attracted attention due to increased DC loads, the popularization of electric vehicles, energy storage systems (ESS), and renewable energy sources such as photovoltaic (PV). This paper studies a ±750 V bipolar DC distribution system and applies a 3-level neutral-point clamped (NPC) AC/DC converter for LVDC distribution. However, the 3-level NPC converter is fundamental in the neutral-point (NP) imbalance problem. This paper discusses the NP balance control method using zero-sequence voltage among various solutions to solve NP imbalance. However, since the zero-sequence voltage for NP balance control is limited, the NP voltage cannot be controlled to be balanced when extreme load differences occur. To maintain microgrid stability with bipolar LVDC distribution, it is necessary to control the NP voltage balance, even in an imbalance of extreme load. In addition, due to the bipolar LVDC distribution, the pole where a short-circuit condition occurs limits the short current until the circuit breaker operates, and a pole without a short-circuit condition must supply a stable voltage. Since the conventional 3-level NPC AC/DC converter alone cannot satisfy both functions, an additional DC/DC converter is proposed, analyzed, and verified. This paper is about a 3-level NPC AC/DC converter system for LVDC distribution. It can be used for the imbalance and short-circuit condition in bipolar LVDC distribution through the prototype of the 300 kW 3-level NPC AC/DC converter system and experimented and verified in various conditions.


2012 ◽  
Vol 27 (2) ◽  
pp. 642-651 ◽  
Author(s):  
Josep Pou ◽  
Jordi Zaragoza ◽  
Salvador Ceballos ◽  
Maryam Saeedifard ◽  
Dushan Boroyevich

Energies ◽  
2019 ◽  
Vol 12 (17) ◽  
pp. 3367 ◽  
Author(s):  
Maosong Zhang ◽  
Ying Cui ◽  
Qunjing Wang ◽  
Jun Tao ◽  
Xiuqin Wang ◽  
...  

This paper proposes an accurate mathematical model of three-level neutral-point-clamped (NPC) converters that can accurately represent the midpoint potential drift of the DC link with parameter perturbation. The mathematical relationships between the fluctuation in neutral-point voltage, the parametric perturbation, and the capacitance error are obtained as mathematical expressions in this model. The expressions can be used to quantitatively analyze the reason for the neutral-point voltage imbalance and balancing effect based on a zero-sequence voltage injection. The injected zero-sequence voltage, which can be used to balance the DC-side voltages with the combined action of active current, can be easily obtained from the proposed model. A balancing control under four-quadrant operation modes is proposed by considering the active current to verify the effectiveness of this model. Both the simulation and experiment results validate the excellent performance of the proposed model compared to the conventional model.


IEEE Access ◽  
2020 ◽  
Vol 8 ◽  
pp. 64799-64809 ◽  
Author(s):  
Jinping Wang ◽  
Zaiyi Gui ◽  
Peixia Wang ◽  
Juncan Wang ◽  
Weidong Jiang

Sign in / Sign up

Export Citation Format

Share Document