Operating modes of dynamic-power-supply transmitter amplifiers

Author(s):  
Earl McCune
2014 ◽  
Vol 568-570 ◽  
pp. 1217-1220
Author(s):  
Shu Lin Liu ◽  
Li Li Qi

In order to improve the efficiency of the switching power supply in whole load range, the controller with PWM, PFM and BURST operating modes is designed in this paper, which changes the operation mode automatically according to the load. The operating principle and the advantages and disadvantages of the three operating modes are analyzed and compared. PWM mode is used in heavy load; PFM mode is used in light load to reduce switching losses by reducing the switching frequency and BURST mode is used at the standby time to further reduce switching losses. The main control module is designed and simulation results verify the feasibility of the designed circuit.


Author(s):  
С.Е. Кузнецов ◽  
Н.А. Алексеев ◽  
А.А. Виноградов

Изложена методика расчета показателей безотказности электроснабжения (вероятности безотказного электроснабжения и средней наработки до отказа) ответственных приемников морского судна, подключаемых к аварийному электрораспределительному щиту. Методика реализована применительно к судовой электроэнергетической системе с тремя источниками электроэнергии – двумя основными дизель-генераторными агрегатами, подключенными к главному электрораспределительному щиту, и одним аварийным дизель-генераторным агрегатом, подключенным к аварийному электрораспределительному щиту. Рассмотрены различные режимы работы судовой электроэнергетической системы: при работе до первого отказа одного основного дизель-генератора, при параллельной работе двух основных дизель-генераторов, при работе одного аварийного дизель-генератора; а также после обесточивания с учетом возможности последующего включения резервного или (и) аварийного дизель генератора. Методика, с соответствующими корректировками, может быть использована для расчета показателей безотказного электроснабжения в судовых электроэнергетических системах другой комплектации. Расчет показателей безотказности электроснабжения необходим при проектировании для обеспечения требуемого уровня надежности электроснабжения судовых приемников электроэнергии, а при эксплуатации – для предупреждения отказов и планирования технического обслуживания и ремонта элементов судовых электроэнергетических систем. The methodology for calculating the indicators of the reliability of power supply (the probability of failure-free power supply and the mean time to failure) of critical receivers of a sea vessel connected to the emergency electrical switchboard is presented. The technique is implemented in relation to a ship power system with three sources of electricity - two main diesel generator sets connected to the main electrical switchboard, and one emergency diesel generator set connected to an emergency electrical switchboard. Various operating modes of the ship's electric power system are considered: during operation until the first failure of one main diesel generator, during parallel operation of two main diesel generators, during operation of one emergency diesel generator; as well as after de-energizing, taking into account the possibility of subsequent switching on of the backup and / or emergency diesel generator. The technique, with appropriate adjustments, can be used to calculate indicators of reliable power supply in ship power systems of a different configuration. Calculation of power supply reliability indicators is necessary during design to ensure the required level of power supply reliability for ship power receivers, and during operation - to prevent failures and plan maintenance and repair of elements of ship power systems.


Author(s):  
Guodong Zhao ◽  
Wenqing Zhang ◽  
Jun Li ◽  
Xin Qi ◽  
Yuntao Liu

2018 ◽  
Vol 2 (2) ◽  
Author(s):  
Yang Li ◽  
Qing Zhou ◽  
Peng Liu ◽  
Jing Zhang ◽  
Fengli Long

Sign in / Sign up

Export Citation Format

Share Document