Investigation of x-ray damage effects on 4T CMOS image sensors

Author(s):  
J. Tan ◽  
A. J. P. Theuwissen
Sensors ◽  
2019 ◽  
Vol 19 (24) ◽  
pp. 5447
Author(s):  
Calvin Yi-Ping Chao ◽  
Shang-Fu Yeh ◽  
Meng-Hsu Wu ◽  
Kuo-Yu Chou ◽  
Honyih Tu ◽  
...  

In this paper we present a systematic approach to sort out different types of random telegraph noises (RTN) in CMOS image sensors (CIS) by examining their dependencies on the transfer gate off-voltage, the reset gate off-voltage, the photodiode integration time, and the sense node charge retention time. Besides the well-known source follower RTN, we have identified the RTN caused by varying photodiode dark current, transfer-gate and reset-gate induced sense node leakage. These four types of RTN and the dark signal shot noises dominate the noise distribution tails of CIS and non-CIS chips under test, either with or without X-ray irradiation. The effect of correlated multiple sampling (CMS) on noise reduction is studied and a theoretical model is developed to account for the measurement results.


2007 ◽  
Author(s):  
Sarah E. Bohndiek ◽  
Costas D. Arvanitis ◽  
Cristian Venanzi ◽  
Gary J. Royle ◽  
Andy T. Clark ◽  
...  

2012 ◽  
Author(s):  
Xinqiao (Chiao) Liu ◽  
Boyd Fowler ◽  
Hung Do ◽  
Mark Jaffe ◽  
Richard Rassel ◽  
...  

2020 ◽  
Vol 67 (1) ◽  
pp. 268-277 ◽  
Author(s):  
Alexandre Le Roch ◽  
Cedric Virmontois ◽  
Philippe Paillet ◽  
Jeffrey H. Warner ◽  
Jean-Marc Belloir ◽  
...  

2019 ◽  
Vol 7 ◽  
pp. 227-238 ◽  
Author(s):  
Calvin Yi-Ping Chao ◽  
Thomas M.-H. Wu ◽  
Shang-Fu Yeh ◽  
Kuo-Yu Chou ◽  
Honyih Tu ◽  
...  

2014 ◽  
Vol 8 (1) ◽  
pp. 152-158
Author(s):  
Zhigang Zhao ◽  
Ru Wang ◽  
Jianheng Huang ◽  
Jinchuan Guo ◽  
Hanben Niu

Fiber optic taper (FOP) array coupled digital x-ray detector can be an ideal choice for large area high resolution x-ray imaging, but its data acquisition system is a challenge, for the reasons such as restrictions of hardware design due to the shape of the FOP array, long distance control requirement in x-ray environment, and arrangement of data transmission sequence among multiple CCD/CMOS image sensors. A FPGA and ARM based data acquisition system for 2×2 FOP array coupled x-ray detector was implemented in this paper. We have finished all the procedures involving the data acquisition system, including hardware and PCB design, FPGA design, ARM and PC software development, and so on. The data acquisition process operates in parallel during parameters setting, 4 CMOS image sensors (LUPA-4000) timing driving, and DDR2 SDRAM data buffering, while it works in series when sending data from each FPGA to ARM and from ARM to PC. Experimental results showed that the data acquisition system worked steadily, and whole images of a custom-built calibration plate were achieved by butting images of the four individual CMOS image sensors’ in visible light test environment. This work could be a valuable foundation for realization of all kinds of FOP array coupled digital x-ray detectors.


Author(s):  
Yue Chen ◽  
Jiaming Tan ◽  
Xinyang Wang ◽  
Adri J Mierop ◽  
Albert J P Theuwissen

2015 ◽  
Vol 10 (01) ◽  
pp. C01002-C01002 ◽  
Author(s):  
A. Castoldi ◽  
C. Guazzoni ◽  
S. Maffessanti ◽  
G.V. Montemurro ◽  
L. Carraresi

Sign in / Sign up

Export Citation Format

Share Document