Crosstalk Of Finite-length Transmission Lines In Arbitrary Directions On The Same Ground Plane

Author(s):  
Y. Kami ◽  
R. Sato
2015 ◽  
Vol 13 ◽  
pp. 161-168 ◽  
Author(s):  
R. Rambousky ◽  
J. Nitsch ◽  
S. Tkachenko

Abstract. By applying the Transmission-Line Super Theory (TLST) to a practical transmission-line configuration (two risers and a horizontal part of the line parallel to the ground plane) it is elaborated under which physical and geometrical conditions the horizontal part of the transmission-line can be represented by a classical telegrapher equation with a sufficiently accurate description of the physical properties of the line. The risers together with the part of the horizontal line close to them are treated as separate lines using the TLST. Novel frequency and local dependent reflection coefficients are introduced to take into account the action of the bends and their radiation. They can be derived from the matrizant elements of the TLST solution. It is shown that the solution of the resulting network and the TLST solution of the entire line agree for certain line configurations. The physical and geometrical parameters for these corresponding configurations are determined in this paper.


Energies ◽  
2019 ◽  
Vol 12 (16) ◽  
pp. 3187 ◽  
Author(s):  
Carlos Tejada-Martinez ◽  
Fermin P. Espino-Cortes ◽  
Suat Ilhan ◽  
Aydogan Ozdemir

In this work, a method to compute the radio interference (RI) lateral profiles generated by corona discharge in high voltage direct current (HVDC) transmission lines is presented. The method is based on a transmission line model that considers the skin effect, through the concept of complex penetration depth, in the conductors and in the ground plane. The attenuation constants are determined from the line parameters and the bipolar system is decoupled by using modal decomposition theory. As application cases, ±500 and ±600 kV bipolar transmission lines were analyzed. Afterwards, parametric sweeps of five variables that affect the RI levels are presented. Both the RI and the maximum electric field were calculated as a function of sub-conductor radius, bundle spacing, and the number of sub-conductors in the bundle. Additionally, the RI levels were also calculated as a function of the soil resistivity, and the RIV (radio interference voltage) frequency. Following this, vector optimization was applied to minimize the RI levels produced by the HVDC lines and differences between the designs with nominal and optimal values are discussed.


Electronics ◽  
2019 ◽  
Vol 8 (12) ◽  
pp. 1475 ◽  
Author(s):  
Vasa Radonić ◽  
Slobodan Birgermajer ◽  
Ivana Podunavac ◽  
Mila Djisalov ◽  
Ivana Gadjanski ◽  
...  

In this paper, we propose a novel metamaterial-based microfluidic sensor that permits the monitoring of properties of the fluid flowing in the microfluidic reservoir embedded between the composite left–right handed (CLRH) microstrip line and the ground plane. The sensor’s working principle is based on the phase shift measurement of the two signals, the referent one that is guided through conventional microstrip line and measurement signal guided through the CLRH line. At the operating frequency of 1.275 GHz, the CLRH line supports electromagnetic waves with group and phase velocities that are antiparallel, and therefore the phase “advance” occurs in the case of CLRH line, while phase delay arises in the right-handed (RH) frequency band. The change of the fluid’s properties that flow in the microfluidic reservoir causes the change of effective permittivity of the microstrip substrate, and subsequently the phase velocity changes, as well as the phase shift. This effect was used in the design of the microfluidic sensor for the measurement of characteristics of the fluid that flows in the microfluidic reservoir placed under the CLRH line. The complete measurement system was developed including the Wilkinson power divider that splits the signal between conventional RH and CLRH section, transmission lines with the microfluidic reservoirs, and a detection circuit for phase shift measurement. Measurement results for different fluids confirm that the proposed sensor is characterized by relatively high sensitivity and good linearity (R2 = 0.94). In this study, the practical application of the proposed sensor is demonstrated for the biomass estimation inside the microfluidic bioreactors, which are used for the cultivation of MRC-5 fibroblasts.


Sign in / Sign up

Export Citation Format

Share Document