A New Camera Calibration Method Based on Two Stages Distortion Model

Author(s):  
Qu Xuejun ◽  
Zhang Lu ◽  
Meng Biao ◽  
Han Zhiren ◽  
Zhang Lingyun
2012 ◽  
Vol 472-475 ◽  
pp. 968-973
Author(s):  
Hong Ru Wang ◽  
Wen Ding

To improve accuracy of computer visual inspection in keyboard automatic assembly line, a new two-stage camera calibration method was presented. 2D circle array was used as calibration plate, and centers of the circles were taken as feature points. And feature point coordinates were extracted without human interference. The proposed camera calibration method was divided into two stages. First, lens distortion was neglected, internal and external parameters of the camera were obtained by modified camera calibration toolbox for MATLAB. Then, lens distortion was taken into account, and improved genetic algorithm (GA) was adopted to optimize camera parameters gotten in the first stage. Experiment results indicate the proposed method is feasible, and can meet with requirements of the given application.


Sensors ◽  
2020 ◽  
Vol 20 (13) ◽  
pp. 3695 ◽  
Author(s):  
Carlos Ricolfe-Viala ◽  
Alicia Esparza

Accurate correction of high distorted images is a very complex problem. Several lens distortion models exist that are adjusted using different techniques. Usually, regardless of the chosen model, a unique distortion model is adjusted to undistort images and the camera-calibration template distance is not considered. Several authors have presented the depth dependency of lens distortion but none of them have treated it with highly distorted images. This paper presents an analysis of the distortion depth dependency in strongly distorted images. The division model that is able to represent high distortion with only one parameter is modified to represent a depth-dependent high distortion lens model. The proposed calibration method obtains more accurate results when compared to existing calibration methods.


2013 ◽  
Vol 475-476 ◽  
pp. 184-187
Author(s):  
Wen Guo Li ◽  
Shao Jun Duan

We present a camera calibration method based on circle plane board. The centres of circles on plane are regarded as the characteristic points, which are used to implement camera calibration. The proposed calibration is more accurate than many previous calibration algorithm because of the merit of the coordinate of circle centre being obtained from thousand of of edge pionts of ellipse, which is very reliable to image noise caused by edge extraction algorithm. Experiments shows the proposed algorithm can obtain high precise inner parameters, and lens distortion parameters.


2014 ◽  
Vol 568-570 ◽  
pp. 320-325 ◽  
Author(s):  
Feng Shan Huang ◽  
Li Chen

A new CCD camera calibration method based on the translation of Coordinate Measuring Machine (CMM) is proposed. The CMM brings the CCD camera to produce the relative translation with respect to the center of the white ceramic standard sphere along the X, Y, Z axis, and the coordinates of the different positions of the calibration characteristic point in the probe coordinate system can be generated. Meanwhile, the camera captures the image of the white ceramic standard sphere at every position, and the coordinates of the calibration characteristic point in the computer frame coordinate system can be registered. The calibration mathematic model was established, and the calibration steps were given and the calibration system was set up. The comparing calibration result shows that precision of this method is equivalent to that of the special calibration method, and the difference between the calibrating data of these two methods is within ±1μm.


2018 ◽  
Vol 10 (8) ◽  
pp. 1298 ◽  
Author(s):  
Lei Yin ◽  
Xiangjun Wang ◽  
Yubo Ni ◽  
Kai Zhou ◽  
Jilong Zhang

Multi-camera systems are widely used in the fields of airborne remote sensing and unmanned aerial vehicle imaging. The measurement precision of these systems depends on the accuracy of the extrinsic parameters. Therefore, it is important to accurately calibrate the extrinsic parameters between the onboard cameras. Unlike conventional multi-camera calibration methods with a common field of view (FOV), multi-camera calibration without overlapping FOVs has certain difficulties. In this paper, we propose a calibration method for a multi-camera system without common FOVs, which is used on aero photogrammetry. First, the extrinsic parameters of any two cameras in a multi-camera system is calibrated, and the extrinsic matrix is optimized by the re-projection error. Then, the extrinsic parameters of each camera are unified to the system reference coordinate system by using the global optimization method. A simulation experiment and a physical verification experiment are designed for the theoretical arithmetic. The experimental results show that this method is operable. The rotation error angle of the camera’s extrinsic parameters is less than 0.001rad and the translation error is less than 0.08 mm.


Sensors ◽  
2021 ◽  
Vol 21 (14) ◽  
pp. 4643
Author(s):  
Sang Jun Lee ◽  
Jeawoo Lee ◽  
Wonju Lee ◽  
Cheolhun Jang

In intelligent vehicles, extrinsic camera calibration is preferable to be conducted on a regular basis to deal with unpredictable mechanical changes or variations on weight load distribution. Specifically, high-precision extrinsic parameters between the camera coordinate and the world coordinate are essential to implement high-level functions in intelligent vehicles such as distance estimation and lane departure warning. However, conventional calibration methods, which solve a Perspective-n-Point problem, require laborious work to measure the positions of 3D points in the world coordinate. To reduce this inconvenience, this paper proposes an automatic camera calibration method based on 3D reconstruction. The main contribution of this paper is a novel reconstruction method to recover 3D points on planes perpendicular to the ground. The proposed method jointly optimizes reprojection errors of image features projected from multiple planar surfaces, and finally, it significantly reduces errors in camera extrinsic parameters. Experiments were conducted in synthetic simulation and real calibration environments to demonstrate the effectiveness of the proposed method.


Sign in / Sign up

Export Citation Format

Share Document