scholarly journals Probabilistic Signal Quality Metric for Reduced Complexity Unsupervised Remote Photoplethysmography

Author(s):  
Y. Benezeth ◽  
S. Bobbia ◽  
K. Nakamura ◽  
R. Gomez ◽  
J. Dubois
2022 ◽  
Vol 12 ◽  
Author(s):  
Silvia Seoni ◽  
Simeon Beeckman ◽  
Yanlu Li ◽  
Soren Aasmul ◽  
Umberto Morbiducci ◽  
...  

Background: Laser-Doppler Vibrometry (LDV) is a laser-based technique that allows measuring the motion of moving targets with high spatial and temporal resolution. To demonstrate its use for the measurement of carotid-femoral pulse wave velocity, a prototype system was employed in a clinical feasibility study. Data were acquired for analysis without prior quality control. Real-time application, however, will require a real-time assessment of signal quality. In this study, we (1) use template matching and matrix profile for assessing the quality of these previously acquired signals; (2) analyze the nature and achievable quality of acquired signals at the carotid and femoral measuring site; (3) explore models for automated classification of signal quality.Methods: Laser-Doppler Vibrometry data were acquired in 100 subjects (50M/50F) and consisted of 4–5 sequences of 20-s recordings of skin displacement, differentiated two times to yield acceleration. Each recording consisted of data from 12 laser beams, yielding 410 carotid-femoral and 407 carotid-carotid recordings. Data quality was visually assessed on a 1–5 scale, and a subset of best quality data was used to construct an acceleration template for both measuring sites. The time-varying cross-correlation of the acceleration signals with the template was computed. A quality metric constructed on several features of this template matching was derived. Next, the matrix-profile technique was applied to identify recurring features in the measured time series and derived a similar quality metric. The statistical distribution of the metrics, and their correlates with basic clinical data were assessed. Finally, logistic-regression-based classifiers were developed and their ability to automatically classify LDV-signal quality was assessed.Results: Automated quality metrics correlated well with visual scores. Signal quality was negatively correlated with BMI for femoral recordings but not for carotid recordings. Logistic regression models based on both methods yielded an accuracy of minimally 80% for our carotid and femoral recording data, reaching 87% for the femoral data.Conclusion: Both template matching and matrix profile were found suitable methods for automated grading of LDV signal quality and were able to generate a quality metric that was on par with the signal quality assessment of the expert. The classifiers, developed with both quality metrics, showed their potential for future real-time implementation.


2008 ◽  
Vol 40 (8) ◽  
pp. 561-575 ◽  
Author(s):  
Michal P. Dlubek ◽  
Andrew J. Phillips ◽  
Eric C. Larkins

2019 ◽  
Vol 2019 (5) ◽  
pp. 528-1-528-6
Author(s):  
Xinwei Liu ◽  
Christophe Charrier ◽  
Marius Pedersen ◽  
Patrick Bours

2012 ◽  
Vol 58 (2) ◽  
pp. 147-152
Author(s):  
Michal Mardiak ◽  
Jaroslav Polec

Objective Video Quality Method Based on Mutual Information and Human Visual SystemIn this paper we present the objective video quality metric based on mutual information and Human Visual System. The calculation of proposed metric consists of two stages. In the first stage of quality evaluation whole original and test sequence are pre-processed by the Human Visual System. In the second stage we calculate mutual information which has been utilized as the quality evaluation criteria. The mutual information was calculated between the frame from original sequence and the corresponding frame from test sequence. For this testing purpose we choose Foreman video at CIF resolution. To prove reliability of our metric were compared it with some commonly used objective methods for measuring the video quality. The results show that presented objective video quality metric based on mutual information and Human Visual System provides relevant results in comparison with results of other objective methods so it is suitable candidate for measuring the video quality.


2019 ◽  
Author(s):  
Mahendra Awale ◽  
Finton Sirockin ◽  
Nikolaus Stiefl ◽  
Jean-Louis Reymond

<div>The generated database GDB17 enumerates 166.4 billion possible molecules up to 17 atoms of C, N, O, S and halogens following simple chemical stability and synthetic feasibility rules, however medicinal chemistry criteria are not taken into account. Here we applied rules inspired by medicinal chemistry to exclude problematic functional groups and complex molecules from GDB17, and sampled the resulting subset evenly across molecular size, stereochemistry and polarity to form GDBMedChem as a compact collection of 10 million small molecules.</div><div><br></div><div>This collection has reduced complexity and better synthetic accessibility than the entire GDB17 but retains higher sp 3 - carbon fraction and natural product likeness scores compared to known drugs. GDBMedChem molecules are more diverse and very different from known molecules in terms of substructures and represent an unprecedented source of diversity for drug design. GDBMedChem is available for 3D-visualization, similarity searching and for download at http://gdb.unibe.ch.</div>


Sign in / Sign up

Export Citation Format

Share Document