visual system
Recently Published Documents


TOTAL DOCUMENTS

5675
(FIVE YEARS 810)

H-INDEX

124
(FIVE YEARS 11)

2022 ◽  
pp. 174702182210746
Author(s):  
Jolene Alexa Cox ◽  
Timothy Walter Cox ◽  
Anne Marie Aimola Davies

Our visual system is built to extract regularities in how objects within our visual environment appear in relation to each other across time and space (‘visual statistical learning’). Existing research indicates that visual statistical learning is modulated by selective attention. Our attentional system prioritises information that enables behaviour; for example, animates are prioritised over inanimates (the ‘animacy advantage’). The present study examined the effects of selective attention and animacy on visual statistical learning in young adults (N = 284). We tested visual statistical learning of attended and unattended information across four animacy conditions: (i) living things that can self-initiate movement (animals); (ii) living things that cannot self-initiate movement (fruits and vegetables); (iii) non-living things that can generate movement (vehicles); and (iv) non-living things that cannot generate movement (tools and kitchen utensils). We implemented a four-point confidence-rating scale as an assessment of participants’ awareness of the regularities in the visual statistical learning task. There were four key findings. First, selective attention plays a critical role by modulating visual statistical learning. Second, animacy does not play a special role in visual statistical learning. Third, visual statistical learning of attended information cannot be exclusively accounted for by unconscious knowledge. Fourth, performance on the visual statistical learning task is associated with the proportion of stimuli that were named or labelled. Our findings support the notion that visual statistical learning is a powerful mechanism by which our visual system resolves an abundance of sensory input over time.


2022 ◽  
Vol 63 (1) ◽  
pp. 3
Author(s):  
Reza Abbas Farishta ◽  
Charlene L. Yang ◽  
Reza Farivar

2022 ◽  
Vol 15 (1) ◽  
Author(s):  
Qian Ren ◽  
Yong Rao

AbstractCoordinated development of neurons and glia is essential for the establishment of neuronal circuits during embryonic development. In the developing Drosophila visual system, photoreceptor (R cell) axons and wrapping glial (WG) membrane extend from the eye disc through the optic stalk into the optic lobe. Extensive studies have identified a number of genes that control the establishment of R-cell axonal projection pattern in the optic lobe. The molecular mechanisms directing the exit of R-cell axons and WG membrane from the eye disc, however, remain unknown. In this study, we show that integrins are required in R cells for the extension of R-cell axons and WG membrane from the eye disc into the optic stalk. Knockdown of integrins in R cells but not WG caused the stalling of both R-cell axons and WG membrane in the eye disc. Interfering with the function of Rhea (i.e. the Drosophila ortholog of vertebrate talin and a key player of integrin-mediated adhesion), caused an identical stalling phenotype. These results support a key role for integrins on R-cell axons in directing R-cell axons and WG membrane to exit the eye disc.


2022 ◽  
Vol 17 (4) ◽  
pp. 800
Author(s):  
Homaira Nawabi ◽  
Noemie Vilallongue
Keyword(s):  

Vision ◽  
2021 ◽  
Vol 6 (1) ◽  
pp. 2
Author(s):  
Irina P. Shepeleva

Among invertebrates, jumping spiders are one of the few groups whose representatives have camera-like eyes, and the only group whose representatives have fovea. The latter is present in the camera-like eyes of representatives of some groups of vertebrates, including humans. Based on the literature data, a comparative analysis of the camera-like eyes of jumping spiders and humans was carried out, in the course of which the similarities and differences in the properties and functions of their basic components were identified. The presented data are necessary for the formation of knowledge about jumping spiders as model animals for studying the functioning of the visual system.


2021 ◽  
Vol 9 (2) ◽  
pp. e1126
Author(s):  
Jennifer S. Graves ◽  
Frederike Cosima Oertel ◽  
Anneke Van der Walt ◽  
Sara Collorone ◽  
Elias S. Sotirchos ◽  
...  

The visual system offers unparalleled precision in the assessment of neuroaxonal damage. With the majority of patients with multiple sclerosis (MS) experiencing afferent and efferent visual dysfunction, outcome measures capturing these deficits provide insight into neuroaxonal injury, even in those with minimal disability. Ideal for use in clinical trials, visual measures are generally inexpensive, accessible, and reproducible. Quantification of visual acuity, visual fields, visual quality of life, and electrophysiologic parameters allows assessment of function, whereas optical coherence tomography (OCT) provides reliable measures of the structural integrity of the anterior afferent visual pathway. The technology of oculomotor biometrics continues to advance, and discrete measures of fixation, smooth pursuit, and saccadic eye movement abnormalities are ready for inclusion in future trials of MS progression. Visual outcomes allow tracking of neuroaxonal injury and aid in distinguishing MS from diseases such as neuromyelitis optica spectrum disorder (NMOSD) or myelin oligodendrocyte glycoprotein antibody–associated diseases (MOGAD). OCT has also provided unique insights into pathophysiology, including the identification of foveal pitting in NMOSD, possibly from damage to Müller cells, which carry an abundance of aquaporin-4 channels. For some study designs, the cost-benefit ratio favors visual outcomes over more expensive MRI outcomes. With the next frontier of therapeutics focused on remyelination and neuroprotection, visual outcomes are likely to take center stage. As an international community of collaborative, committed, vision scientists, this review by the International MS Visual System Consortium (IMSVISUAL) outlines the quality standards, informatics, and framework needed to routinely incorporate vision outcomes into MS and NMOSD trials.


Electronics ◽  
2021 ◽  
Vol 11 (1) ◽  
pp. 54
Author(s):  
Xiliang Zhang ◽  
Tang Zheng ◽  
Yuki Todo

As an important part of the nervous system, the human visual system can provide visual perception for humans. The research on it is of great significance to improve our understanding of biological vision and the human brain. Orientation detection, in which visual cortex neurons respond only to linear stimuli in specific orientations, is an important driving force in computer vision and biological vision. However, the principle of orientation detection is still unknown. This paper proposes an orientation detection mechanism based on dendrite calculation of local orientation detection neurons. We hypothesized the existence of orientation detection neurons that only respond to specific orientations and designed eight neurons that can detect local orientation information. These neurons interact with each other based on the nonlinearity of dendrite generation. Then, local orientation detection neurons are used to extract local orientation information, and global orientation information is deduced from local orientation information. The effectiveness of the mechanism is verified by computer simulation, which shows that the machine can perform orientation detection well in all experiments, regardless of the size, shape, and position of objects. This is consistent with most known physiological experiments.


2021 ◽  
Vol 15 ◽  
Author(s):  
Irina Shoshina ◽  
Inna Zelenskaya ◽  
Valeriia Karpinskaia ◽  
Yuri Shilov ◽  
Elena Tomilovskaya

The aim of this work was to study the sensitivity of the visual system in 5-day “dry” immersion with a course of high-frequency electromyostimulation (HFEMS) and without it. “Dry” immersion (DI) is one of the most effective models of microgravity. DI reproduces three basic effects of weightlessness: physical inactivity, support withdrawal and elimination of the vertical vascular gradient. The “dry” immersion included in the use of special waterproof and highly elastic fabric on of immersion in a liquid similar in density to the tissues of the human body. The sensitivity of the visual system was assessed by measuring contrast sensitivity and magnitude of the Müller-Lyer illusion. The visual contrast sensitivity was measured in the spatial frequency range from 0.4 to 10.0 cycles/degree. The strength of visual illusion was assessed by means of motor response using “tracking.” Measurements were carried out before the start of immersion, on the 1st, 3rd, 5th days of DI, and after its completion. Under conditions of “dry” immersion without HFEMS, upon the transition from gravity to microgravity conditions (BG and DI1) we observed significant differences in contrast sensitivity in the low spatial frequency range, whereas in the experiment with HFEMS—in the medium spatial frequency range. In the experiment without HFEMS, the Müller-Lyer illusion in microgravity conditions was absent, while in the experiment using HFEMS it was significantly above zero at all stages. Thus, we obtained only limited evidence in favor of the hypothesis of a possible compensating effect of HFEMS on changes in visual sensitivity upon the transition from gravity to microgravity conditions and vice versa. The study is a pilot and requires further research on the effect of HFEMS on visual sensitivity.


Sign in / Sign up

Export Citation Format

Share Document