The comparison of tuning algorithms used in Petersen coil model

Author(s):  
Filip Susko ◽  
Andrej Bolf ◽  
Pavol Belany ◽  
Michal Repak ◽  
Juraj Altus ◽  
...  
Keyword(s):  
Author(s):  
Dumitru Toader ◽  
Costantin Blaj ◽  
Petru Ruset ◽  
Ioan Dorin Hategan ◽  
Nicolae Pinte ◽  
...  

2011 ◽  
Vol 26 (2) ◽  
pp. 1290-1291 ◽  
Author(s):  
Xiangning Lin ◽  
Jingguang Huang ◽  
Shuohao Ke
Keyword(s):  

2013 ◽  
Vol 860-863 ◽  
pp. 2007-2012 ◽  
Author(s):  
Xiao Meng ◽  
Neng Ling Tai ◽  
Yan Hu ◽  
Xia Yang

The failure current in resonant grounder power distribution system is small, so it is difficult to detect the fault feeder. This passage presents the equivalent circuit of resonant grounded system, and discusses the difference of electrical characteristics between faulty feeder and sound feeders by using shunt resistors. To reduce the influence of shunt resistors on the system and improve the detection sensitivity, it presents the method of shunting multi-level resistors, and it proves the sensitivity and reliability of this method by EMTP simulation.


Author(s):  
Xu Yao ◽  
Zeng Xiangjun ◽  
Liu Zhanglei ◽  
Yi Wentao

Energies ◽  
2021 ◽  
Vol 14 (5) ◽  
pp. 1330
Author(s):  
Dumitru Toader ◽  
Marian Greconici ◽  
Daniela Vesa ◽  
Maria Vintan ◽  
Claudiu Solea

Settings of protection are essential to ensure the sensitivity and selectivity needed to detect defects. Making the correct settings requires the calculation of the fault currents with as little error as possible. Fault currents are influenced by the parameters of the electrical networks, including the state of the insulation and the Petersen coil, which changes during their operation electrical networks. This paper analyzes how the insulation parameters of medium voltage power lines, the parameters of the Petersen coil used to treat the neutral of the medium voltage electrical network and the value of the resistance at the fault location influence the fault current in the case of a single-phase fault. The large number of single-phase faults that occur in medium voltage electrical networks justifies this analysis. The symmetrical components method was used to calculate the fault current. The results obtained by calculation were verified experimentally by causing a single-phase-to-ground fault in a real medium voltage network. The paper presents the situations in which the analytical calculation of the single-phase-to-ground fault current can lead to inadmissibly large errors, even over 50%, but also the situations in which the errors fall below 3%.


Sign in / Sign up

Export Citation Format

Share Document