The identification of opportunities to improve pump system maintenance and reduce system energy losses

Author(s):  
Roger Lawrence
2020 ◽  
Vol 38 (5) ◽  
pp. 1983-1997
Author(s):  
Feng Rong ◽  
Li Xiuzhen ◽  
Zhao Xingcheng ◽  
Fang Junfei

The ventilator of the heating tower and the circulating pump of the anti-freeze solution are the main electrical equipment of a heating tower heat pump system, besides the compressor. By controlling the working frequencies of the ventilator of the heating tower and circulating pump of the anti-freeze solution, the effects of the operation parameters of a closed-type heating tower on its heat absorption and the performance of heating tower heat pump system were investigated under winter heat conditions. The results indicated that reducing the frequency of the circulating pump for the anti-freeze solution leads to a decrease in the temperature of the outlet evaporator of the anti-freezing solution and an increased temperature difference between the anti-freeze solution flowing into and out of the heating tower; meanwhile, excessively high and low anti-freeze flow rates lead to reduced heat absorption of the closed-type heating tower. The coefficient of performance fluctuates slightly if the frequency of circulating pump is above 20 Hz, but a slight drop in coefficient of performance is observed when the frequency is less than 15 Hz. The system energy efficiency ratio tends to increase as the frequency of circulating pump is reduced, although a substantial reduction occurs at 10 Hz. Furthermore, a reduced ventilator frequency decreases the temperatures of the anti-freeze solution at the inlet and outlet of the heating tower and the temperature difference, hindering the heat absorption of the heating tower. With reductions in the ventilator frequency, the coefficient of performance exhibits an initial increase followed by subsequent decreases, while the system energy efficiency ratio showed continual increases until the ventilator frequency dropped to 10 Hz. When the ventilator frequency or circulating pump frequency drops to 15 Hz and 10 Hz, the evaporation temperature of the heat pump unit decreases, resulting in an excessively exhaust temperature, which is not favorable for the safe operation of the system.


Author(s):  
Rizky Rahmat Maulana ◽  
S Salahuddin ◽  
E Ezwarsyah ◽  
Baharuddin Ismail ◽  
Ashish Shrestha ◽  
...  

Energy loss (losses) is the loss of a certain amount of energy generated when it is distributed to consumers so that it affects the profitability of the company concerned. The size of the losses from an electric power system shows the level of efficiency of the system, the lower the percentage of losses that occur the more efficient the system. Energy losses in the distribution network are generally divided into two, namely technical and non-technical losses. The calculation of technical losses in the 20 KV medium distribution network of PT PLN (Persero) Ulp Matang Glumpang Dua is carried out using the load curve approach method and using the help of the Microsoft Exel program, while the technical losses calculated are technical losses on the Medium Voltage Network and Distribution Transformer. From the results of the analysis of the calculation of technical losses in 2020, the total technical loss value at MG-01 Matang City is in the range of 13.8% to 20.8% which consists of the average technical loss in the Medium Voltage Network feeder of 0.02%. and the loss of Distribution Transformer by 17.6%.


Solar Energy ◽  
2013 ◽  
Vol 97 ◽  
pp. 112-121 ◽  
Author(s):  
Bill Marion ◽  
Robert Schaefer ◽  
Holden Caine ◽  
Gonzalo Sanchez

Sign in / Sign up

Export Citation Format

Share Document