Reactive power control strategy for voltage regulation and power-factor correction in MV distribution networks

Author(s):  
F.M. Gatta ◽  
A. Geri ◽  
M. Maccioni ◽  
A. Mantineo ◽  
M. Cresta ◽  
...  
Energies ◽  
2021 ◽  
Vol 14 (19) ◽  
pp. 6413
Author(s):  
Feng-Chang Gu ◽  
Hung-Cheng Chen

Large-scale wind farms in commercial operations have demonstrated growing influence on the stability of an electricity network and the power quality thereof. Variations in the output power of large-scale wind farms cause voltage fluctuations in the corresponding electrical networks. To achieve low-voltage ride-through capability in a doubly fed induction generator (DFIG) during a fault event, this study proposes a real-time reactive power control strategy for effective DFIG application and a static synchronous compensator (STATCOM) for reactive power compensation. Mathematic models were developed for the DFIG and STATCOM, followed by the development of an indirect control scheme for the STATCOM based on decoupling dual-loop current control. Moreover, a real-world case study on a commercial wind farm comprising 23 DFIGs was conducted. The voltage regulation performance of the proposed reactive power control scheme against a fault event was also simulated. The simulation results revealed that enhanced fault ride-through capability and prompt recovery of the output voltage provided by a wind turbine generator could be achieved using the DFIG along with the STATCOM in the event of a three-phase short-circuit fault.


Electronics ◽  
2021 ◽  
Vol 10 (13) ◽  
pp. 1569
Author(s):  
Dilini Almeida ◽  
Jagadeesh Pasupuleti ◽  
Janaka Ekanayake

The greater integration of solar photovoltaic (PV) systems into low-voltage (LV) distribution networks has posed new challenges for the operation of power systems. The violation of voltage limits attributed to reverse power flow has been recognized as one of the significant consequences of high PV penetration. Thus, the reactive power control of PV inverters has emerged as a viable solution for localized voltage regulation. This paper presents a detailed study on a typical Malaysian LV distribution network to demonstrate the effectiveness of different reactive power control techniques in mitigating overvoltage issues due to high PV integration. The performance of four reactive power control techniques namely, fixed power factor control, scheduled power factor control, power factor control as a function of injected active power, and voltage-dependent reactive power control were analyzed and compared in terms of the number of customers with voltage violations, reactive power compensation, and network losses. Three-phase, time-series, high-resolution power-flow simulations were performed to investigate the potential overvoltage issues and to assess the performance of the adoption of reactive power controls in the network. The simulation results revealed that the incorporation of reactive power controls of solar PV inverters aids in successfully mitigating the overvoltage issues of typical Malaysian networks. In particular, the Volt-Var control outperformed the other control techniques by providing effective voltage regulation while requiring less reactive power compensation. Furthermore, the comparative analysis highlighted the significance of employing the most appropriate control technique for improved network performance.


Sign in / Sign up

Export Citation Format

Share Document