Proportional Multi Resonant Controller based Cascaded Voltage Control Scheme of Three Phase Four Leg Inverter for Nonlinear loads in OFF Grid Solar Photovoltaic Applications

Author(s):  
Sai Chaitanya Ikkurti ◽  
Hanumath Prasad Ikkurti
2015 ◽  
Vol 2015 ◽  
pp. 1-9 ◽  
Author(s):  
Z. Chelli ◽  
R. Toufouti ◽  
A. Omeiri ◽  
S. Saad

This paper focuses on a four-wire shunt active power filter (APF) control scheme proposed to improve the performance of the APF. This filter is used to compensate harmonic distortion in three-phase four-wire systems. Several harmonic suppression techniques have been widely proposed and applied to minimize harmonic effects. The proposed control scheme can compensate harmonics and reactive power of the nonlinear loads simultaneously. This approach is compared to the conventional shunt APF reference compensation strategy. The developed algorithm is validated by simulation tests using MATLAB Simulink. The obtained results have demonstrated the effectiveness of the proposed scheme and confirmed the theoretical developments for balanced and unbalanced nonlinear loads.


2019 ◽  
Vol 9 (5) ◽  
pp. 952 ◽  
Author(s):  
S. Mohamed ◽  
P. Jeyanthy ◽  
D. Devaraj ◽  
M. Shwehdi ◽  
Adel Aldalbahi

The high penetration level of solar photovoltaic (SPV) generation systems imposes a major challenge to the secure operation of power systems. SPV generation systems are connected to the power grid via power converters. During a fault on the grid side; overvoltage can occur at the direct current link (DCL) due to the power imbalance between the SPV and the grid sides. Subsequently; the SPV inverter is disconnected; which reduces the grid reliability. DC-link voltage control is an important task during low voltage ride-through (LVRT) for SPV generation systems. By properly controlling the power converters; we can enhance the LVRT capability of a grid-connected SPV system according to the grid code (GC) requirements. This study proposes a novel DCL voltage control scheme for a DC–DC converter to enhance the LVRT capability of the two-stage grid-connected SPV system. The control scheme includes a “control without maximum power point tracking (MPPT)” controller; which is activated when the DCL voltage exceeds its nominal value; otherwise, the MPPT control is activated. Compared to the existing LVRT schemes the proposed method is economical as it is achieved by connecting the proposed controller to the existing MPPT controller without additional hardware or changes in the software. In this approach, although the SPV system will not operate at the maximum power point and the inverter will not face any over current challenge it can still provide reactive power support in response to a grid fault. A comprehensive simulation was carried out to verify the effectiveness of the proposed control scheme for enhancing the LVRT capability and stability margin of an interconnected SPV generation system under symmetrical and asymmetrical grid faults.


2015 ◽  
Vol 62 (4) ◽  
pp. 2073-2081 ◽  
Author(s):  
Eun-Kyung Kim ◽  
Francis Mwasilu ◽  
Han Ho Choi ◽  
Jin-Woo Jung

2014 ◽  
Vol 1049-1050 ◽  
pp. 669-673
Author(s):  
Jun Gu ◽  
Xing Zhang ◽  
Shan Shou Li

Because the line impedance of low-voltage microgrids is mainly resistive and the transfer impedance of microgrid inverters is usually mismatched, a virtual reactance is usually added to the control loop of each microgrid inverter. It is found that the existing two virtual reactance implementation methods introduce harmonic components into the voltage control units of microgrid inverters in the condition of nonlinear loads after the theory and simulation analyses. To solve the problem, a second-order general-integrator (SOGI) virtual impedance implementation method of droop-controlled three-phase microgrid inverters is proposed. Simulation results are provided to show the feasibility of the proposed method.


Sign in / Sign up

Export Citation Format

Share Document