Noise and Noise-Rejection Methods in Control Circuits, Particularly for High-Voltage Power Stations

Author(s):  
Bertil Hammarlund
2021 ◽  
Vol 52 (5) ◽  
pp. 32-35
Author(s):  
Miro Zeman

We are used to the continuous supply of electricity from a socket. Behind the socket lies a complex system of large power stations, high-voltage cables, transformers and a distribution network. Little has changed in the system over the last fifty years. The ambition to generate sustainable electricity from variable solar and wind energy has an immense impact on the electricity sector and requires major changes in our electricity grid and its operation.


2017 ◽  
Vol 65 (6) ◽  
pp. 871-882
Author(s):  
M. Szewczyk

AbstractVery fast transient overvoltages (VFTO) originate from steep voltage breakdowns in SF6gas that are inherent to operation of any switching device of the gas-insulated switchgear (GIS) type. For power stations with voltage ratings exceeding 500 kV, the ratio between equipment rated- and withstand-voltage levels becomes relatively low, which causes the VFTO peak values to reach the component’s insulation withstand-voltage levels, thus becoming a design factor for high- and ultra-high voltage GIS. While well-established approach to VFTO analyses involves only single VFTO events (the so-called single-spark approach), there is often the need to analyze the entire VFTO generation process, for which the multi-spark approach to VFTO modeling is to be employed. The multi-spark approach allows one to evaluate the VFTO impact on the GIS disconnector design along with the impact of the VFTO on selection and dimensioning of the VFTO damping solutions. As the multi-spark approach to VFTO modeling is now being increasingly used in UHV GIS developments as well as for the insulation co-ordination studies of power stations, the present paper is motivated by the need to report on the VFTO multi-spark modeling approach and to lay a common ground for development works that are supported extensively with VFTO simulations. The paper presents physical assumptions and modeling concepts that are in use in such modeling works. Development of the multi-spark GIS disconnector model for VFTO simulations is presented, followed by an overview of examples of the model application for the GIS development works and for insulation co-ordination studies.


Author(s):  
Mihaela Frigura-Iliasa ◽  
Felicia I. Baloi ◽  
Adrian F. Olariu ◽  
Doru Vatau ◽  
Razvan C. Petrenci ◽  
...  

Machines ◽  
2021 ◽  
Vol 9 (5) ◽  
pp. 99
Author(s):  
Caius Panoiu ◽  
Dumitru Ciulica ◽  
Manuela Panoiu ◽  
Sergiu Mezinescu

This paper addresses one of the current areas of interest in electrical engineering, which is controlled switching of high voltage circuit breakers. During their operation, the problem of controlled switching of high voltage circuit breakers in commutation regimes was studied. Several types of switching were analyzed, considered representative of the transient regime, depending on the type of load, on the defect that may occur on the power supply lines, as well as depending on the position of this defect (near or far). The study carried out in the paper includes simulations of the controlled connection/disconnection operations in a transient regime, assuming the existence of different kinds of defects. To perform the study and simulations in the transient regime, a model, implemented in Matlab, was used for a time interval located around the origin of the time axis. The study included the dependence of the SF6 circuit breaker switching process on the following parameters: the DC voltage supply, ambient temperature and oil pressure in the circuit breaker actuator. The validity of the theory presented in this paper, in addition to being validated by simulations, is proven by the fact that the protection system currently in use at the power station of an 800 MW power plant, at the 400 kV power line, is based on the principles presented in this paper. The theory presented in the paper has been implemented in industry for nearly two years, and the results confirm that the theory presented in the paper is fully applicable in high voltage power stations.