Electromagnetic Environment Analysis of a Software Park Near Transmission Lines

2004 ◽  
Vol 40 (4) ◽  
pp. 995-1002 ◽  
Author(s):  
J. He ◽  
S. Chen ◽  
J. Guo ◽  
R. Zeng ◽  
J. Lee ◽  
...  
2014 ◽  
Vol 602-605 ◽  
pp. 2637-2640
Author(s):  
Ao Wang ◽  
Yu Hui Zhu ◽  
Rui Guan ◽  
Zi Wei Chen ◽  
Lian Qing Zhao

The research on 1000kV UHV AC transmission lines is to analysis the electromagnetic field strength around these lines, as well as the electromagnetic energy people absorbed at different distances under the lines. What’s more, suggestions for a further study and standards to improve are provided in the paper.


Author(s):  
Nina B. Rubtsova ◽  
Sergey Yu. Perov ◽  
Olga V. Belaya ◽  
Tatiana A. Konshina

Introduction. Electromagnetic safety of power grid facilities staff requires the exclusion of electromagnetic fields (EMF) harmful effects. EMF is evaluated by 50 Hz electric and magnetic fields (EF and MF) values in the framework of working conditions special assessment, and very rarely the analysis of the electromagnetic environment (EME) is carried out in depth. The aim of the study - EME hygienic assessment of power grid EHV facilities personnel workplace with adequate 50 Hz EF and MF levels evaluation as well as the analysis of EF and MF in the frequency range from 5 Hz to 500 Hz amplitude-frequency characteristics. Materials and methods. 50 Hz EF and MF values assessment was carried out on open switchgears (S) of substations and within sanitary breaks of 500 and 750 kV overhead power transmission lines (OTL). Measurements along to OTL trasses was performed using matrix-based method. Measurements and analysis of EF and MF values in 5-500 Hz frequency range amplitude-frequency characteristics were performed in the territory of 500 and 750 kV S. Results. Power frequency 50 Hz measurements results at 500 and 750 kV S ground-level personnel workplaces showed the presence of an excess of permissible limit values by EF intensity and the absence of an excess by MF. The measured EF values within 500 and 750 kV OTL sanitary gaps require limiting the working time of linemen due to the excess of the hygienic norms for full work shift, while the MP levels were almost completely within the standard values for persons not occupationally connected with electrical installations maintenance. MF and EE frequency range from 50 Hz to 500 Hz spectral characteristics analysis showed that 3rd harmonic percentage does not exceed 2.5% for EF and 6% for MF of the main level, the level of the 5th harmonic does not exceed 1% for EF and 3.5% for MF, the level of the 7th harmonic does not exceed 0.2% for EF and 0.8% for MF. These data show despite its low levels the contribution of MF different harmonics in a possible adverse impact on humane than EF corresponding harmonics. Conclusions. There was the confirmation of the previously justified use of the "matrix" scheme for of EF and MF values measurement along OTL routes. The relevance of to EF and MF all frequency components expos ure assessing possible health risk in extremely high voltage S territories and under OTL, based on international recommendations due to the lack of sanitary regulations in the Russian Federation for >50 Hz-30 kHz EF and MF, is shown.


2014 ◽  
Vol 1022 ◽  
pp. 165-168
Author(s):  
Pei Lin Li ◽  
Si Qi Lv ◽  
Tian Le Li

With the increasing development of China's power transmission project and social awareness of environmental protection, the problem of electromagnetic environment of transmission line has been widely concerned. This paper studies the electromagnetic environment around the transmission lines, analyzes the calculation method of power frequency electromagnetic field and the measures to reduce the power frequency electromagnetic field.


2013 ◽  
Vol 805-806 ◽  
pp. 911-914 ◽  
Author(s):  
Xiao Bo Wang ◽  
Tie Bing Lu ◽  
Yong Zan Zhen ◽  
Yu Xiang

With the HVDC transmission projects developing rapidly, the relevent electromagnetic environment problems are widely concerned, of which the transient electric caused by the conductor electrification in ionized field may seriously influences the feelings of people. To invesigate the tansient electric shock procedure, the transient current is measured in the experiment. The simulation results agrees well with the measured values and the validity of the simulation model is verified. The simulation results show that the resistance in the discharging circuit can reduce the current evidently. It is also found that the metal objects under the HVDC lines should be grouded to avoid discharging when touched by the people.