Embedded Algorithm for QRS Detection Based on Signal Shape

2021 ◽  
Vol 70 ◽  
pp. 1-12
Author(s):  
Fabrice Tueche ◽  
Youssoufa Mohamadou ◽  
Arsene Djeukam ◽  
Landry Cabrel Njike Kouekeu ◽  
Rene Seujip ◽  
...  
Keyword(s):  
2020 ◽  
Author(s):  
Junaid Khan

While self mixing interferometry(SMI) has proven to be suitable for displacement measurement and other sensing applications,its characteristic self mixing signal shape is strongly governed by the non-linear phase equation which forms relation between perturbed and unperturbed phase of self mixing laser.Therefore, while it is desirable for robust estimation of displacement of moving target, the algorithms to achieve this must have an objective strategy which can be achieved by understanding the characteristic of extracting knowledge of perturbed phase from unperturbed phase. Therefore, it has been proved and shown that such strategy must not involve sole methods where perturbed phase is continuous function of unperturbed phase (e.g:Taylor series or fixed point methods) or through successive displacements (e.g: variations of Gauss Seidal method). Subset of this strategy is to perform spectral filtering of perturbed phase followed by perturbative or homotopic deformation. A less computationally expensive approach of this strategy is adopted to achieve displacement with mean error of 62.2nm covering all feedback regimes, when coupling factor 'C' is unknown.<br>


2021 ◽  
pp. 105097
Author(s):  
Rafael Sanchotene Silva ◽  
Afonso Roberto Plantes Neto ◽  
Jefferson Luiz Brum Marques ◽  
Omid Kavehei ◽  
Cesar Ramos Rodrigues

2016 ◽  
Vol 78 (7-5) ◽  
Author(s):  
Muhammad Amin Hashim ◽  
Yuan Wen Hau ◽  
Rabia Baktheri

This paper studies two different Electrocardiography (ECG) preprocessing algorithms, namely Pan and Tompkins (PT) and Derivative Based (DB) algorithm, which is crucial of QRS complex detection in cardiovascular disease detection. Both algorithms are compared in terms of QRS detection accuracy and computation timing performance, with implementation on System-on-Chip (SoC) based embedded system that prototype on Altera DE2-115 Field Programmable Gate Array (FPGA) platform as embedded software. Both algorithms are tested with 30 minutes ECG data from each of 48 different patient records obtain from MIT-BIH arrhythmia database. Results show that PT algorithm achieve 98.15% accuracy with 56.33 seconds computation while DB algorithm achieve 96.74% with only 22.14 seconds processing time. Based on the study, an optimized PT algorithm with improvement on Moving Windows Integrator (MWI) has been proposed to accelerate its computation. Result shows that the proposed optimized Moving Windows Integrator algorithm achieves 9.5 times speed up than original MWI while retaining its QRS detection accuracy. 


2016 ◽  
Vol 14 (4) ◽  
pp. 1662-1668 ◽  
Author(s):  
Ernano Arrais Junior ◽  
Ricardo Alexandro de Medeiros Valentim ◽  
Glaucio Bezerra Brandao

Sign in / Sign up

Export Citation Format

Share Document