On-Site Low Voltage Determination of Zero-Sequence Impedances for Power Transformers

2020 ◽  
Vol 35 (2) ◽  
pp. 1048-1057
Author(s):  
Haytham Saeed ◽  
Mariana Kamel ◽  
Abdelrahman Karrar ◽  
Ahmed H. Eltom ◽  
Mark Bowman
2020 ◽  
Vol 2020 (6) ◽  
pp. 43-46
Author(s):  
A.F. Zharkin ◽  
◽  
S.O. Palachov ◽  
A.G. Pazieiev ◽  
D.O. Malakhatka ◽  
...  

Ways of searching for optimal ways to improve the quality of electric energy in electric networks with dispersed unbalanced loads using zero-sequence current filters are considered, which take into account the possibility of ensuring the desired performance with minimal cost and taking into account the peculiarities of operation in emergency network conditions and ensuring electrical safety of consumers. Corresponding calculations were carried out using simulation modeling. References 6, figures 4.


Author(s):  
Mariana Kamel ◽  
Haytham Saeed ◽  
Abdelrahman Karrar ◽  
Ahmed Eltom ◽  
Mark Bowman ◽  
...  
Keyword(s):  

Author(s):  
A. V. Lykin ◽  
E. A. Utkin

The article considers the feasibility of changing the structure of a distribution electrical network by transferring points of electricity transformation as close to consumers as possible. This approach is based on installation of pole-mounted transformer substations (PMTS) near consumer groups and changes the topology of the electrical network. At the same time, for groups of consumers, the configuration of sections of the low-voltage network, including service drops, changes. The efficiency of approaching transformer substations to consumers was estimated by the reduction in electrical energy losses due to the expansion of the high-voltage network. The calculation of electrical losses was carried out according to twenty-four hour consumer demand curve. To estimate the power losses in each section of the electrical network of high and low voltage, the calculated expressions were obtained. For the considered example, the electrical energy losses in the whole network with a modified topology is reduced by about two times, while in a high-voltage network with the same transmitted power, the losses are reduced to a practically insignificant level, and in installed PMTS transformers they increase mainly due to the rise in total idle losses. The payback period of additional capital investments in option with modified topology will be significantly greater if payback is assessed only by saving losses cost. Consequently, the determination of the feasibility of applying this approach should be carried out taking into account such factors as increasing the reliability of electricity supply, improving the quality of electricity, and increasing the power transmission capacity of the main part of electrical network.


Author(s):  
Philippe Steinbusch ◽  
Jan Meese ◽  
Roman Uhlig ◽  
Jan Mehlich ◽  
Marcus Stotzel ◽  
...  
Keyword(s):  

Electronics ◽  
2019 ◽  
Vol 8 (6) ◽  
pp. 691 ◽  
Author(s):  
Ju-Yong Kim ◽  
Ho-Sung Kim ◽  
Ju-Won Baek ◽  
Dong-Keun Jeong

Low-voltage direct current (LVDC) distribution has attracted attention due to increased DC loads, the popularization of electric vehicles, energy storage systems (ESS), and renewable energy sources such as photovoltaic (PV). This paper studies a ±750 V bipolar DC distribution system and applies a 3-level neutral-point clamped (NPC) AC/DC converter for LVDC distribution. However, the 3-level NPC converter is fundamental in the neutral-point (NP) imbalance problem. This paper discusses the NP balance control method using zero-sequence voltage among various solutions to solve NP imbalance. However, since the zero-sequence voltage for NP balance control is limited, the NP voltage cannot be controlled to be balanced when extreme load differences occur. To maintain microgrid stability with bipolar LVDC distribution, it is necessary to control the NP voltage balance, even in an imbalance of extreme load. In addition, due to the bipolar LVDC distribution, the pole where a short-circuit condition occurs limits the short current until the circuit breaker operates, and a pole without a short-circuit condition must supply a stable voltage. Since the conventional 3-level NPC AC/DC converter alone cannot satisfy both functions, an additional DC/DC converter is proposed, analyzed, and verified. This paper is about a 3-level NPC AC/DC converter system for LVDC distribution. It can be used for the imbalance and short-circuit condition in bipolar LVDC distribution through the prototype of the 300 kW 3-level NPC AC/DC converter system and experimented and verified in various conditions.


2011 ◽  
Vol 128-129 ◽  
pp. 190-195
Author(s):  
Hua Lin Liu ◽  
Yin Bo Zhan ◽  
Xiao Lei ◽  
You Yuan Wang ◽  
Hua Rong Zeng ◽  
...  

As we know, the TF method is more sensitive to changes in the power transformers at higher frequencies. Although measurement based on low voltage impulse (LVI) is definitely faster than that based on swept frequency method (SFM), the available frequency band is narrow because of the typical microsecond impulse. In this paper, the characteristics of the nanosecond impulse in the frequency domain were investigated. A test System based on Nanosecond low voltage impulse was developed. The proposed method was applied to a 10kV/100kVA distribution transformer in the laboratory. Measurement results with two different impulses were compared.