Theoretical Parameter Design Method of SFCL for Concurrent Commutation Failure Inhibition in SFCL-Segmented Multi-Infeed LCC-HVDC Systems

2020 ◽  
Vol 35 (3) ◽  
pp. 1741-1757 ◽  
Author(s):  
Yinhong Li ◽  
Hao Xiao ◽  
Xianzhong Duan
IEEE Access ◽  
2020 ◽  
Vol 8 ◽  
pp. 18669-18680 ◽  
Author(s):  
Bingkun Li ◽  
Yuansheng Liang ◽  
Gang Wang ◽  
Haifeng Li ◽  
Xinquan Chen

2021 ◽  
Vol 36 (6) ◽  
pp. 726-733
Author(s):  
Yongjie Zhang ◽  
Xiaofeng Deng

In this study, 2D finite element (FE) solving process with the conformal perfectly matched layer (PML) is elucidated to perform the electromagnetic scattering computation. With the 2D monostatic RCS as the optimization objective, a sensitivity analysis of the basic design parameters of conformal PML (e.g., layer thickness, loss factor, extension order and layer number) is conducted to identify the major parameters of conformal PML that exerts more significant influence on 2D RCS. Lastly, the major design parameters of conformal PML are optimized by the simulated annealing algorithm (SA). As revealed from the numerical examples, the parameter design and optimization method of conformal PML based on SA is capable of enhancing the absorption effect exerted by the conformal PML and decreasing the error of the RCS calculation. It is anticipated that the parameter design method of conformal PML based on RCS optimization can be applied to the cognate absorbing boundary and 3D electromagnetic computation.


IEEE Access ◽  
2020 ◽  
Vol 8 ◽  
pp. 189878-189890
Author(s):  
Faban Zheng ◽  
Weimin Wu ◽  
Bolin Chen ◽  
Eftichios Koutroulis

Energies ◽  
2019 ◽  
Vol 12 (12) ◽  
pp. 2338 ◽  
Author(s):  
Wang ◽  
Zhang ◽  
Song ◽  
Cao

Owing to the necessity of the transformer for the multi-parallel inverters connected to the medium-voltage (MV) grid, the conventional multi-parallel inverter topology can be reconfigured to the dual-inverter fed open-end winding transformer (DI-OEWT) topology to obtain lower output voltage harmonics, which can reduce the requirement of the filter inductance. However, due to the special structure of the DI-OEWT topology, the arrangement scheme of the filter can be more than one kind, and different schemes may affect the filter performance. In this paper, research on the existing two kinds of filters, as well as a proposed one, for the DI-OEWT topology used in photovoltaic grid-tied applications is presented. The equivalent circuits of these filters are derived, and based on this, the harmonic suppression capability of these filters is analyzed and compared. Furthermore, a brief parameter design method of these filters is also introduced, and based on the design examples, the inductance and capacitance requirements of these filters are compared. In addition, these filters are also evaluated in terms of the applicability for fault tolerance. At last, the analysis is verified through an experiment on a 30 kW dual-three-level inverter prototype.


Sign in / Sign up

Export Citation Format

Share Document