A new high accuracy super-short baseline (SSBL) system

Author(s):  
M. Watson ◽  
C. Loggins ◽  
Y.T. Ochi
Keyword(s):  
2012 ◽  
Vol 18 (4) ◽  
pp. 645-660 ◽  
Author(s):  
R. Cuneyt Erenoglu ◽  
Mehmet Ali Yucel ◽  
Atinc Pirti ◽  
D. Ugur Sanli

In geodetic applications variety, one of the main current focuses is recently to determine the heights of ground stations with high accuracy. Specially the possibility of acquiring 3D information of the point positioning with high accuracy is opening up new strategies of investigating the heighting. Global Navigation Satellite System (GNSS) for 3D positioning is undergoing rapid developments and GNSS heighting can be an alternative to terrestrial techniques of height measurements. This paper presents a research study on the use of GNSS heighting in the case of steep slopes and multipath issue. Short baseline solution strategies were performed by using Bernese Software v. 5.0. The analysis results are also compared to the results of techniques of the terrestrial levelling. The results show that GNSS can be used as an practical surveying method to the terrestrial levelling with comparable accuracies. Furthermore, one can save up to 1 hour using GNSS instead of geometric levelling over a steep slope of a 100 m. On the other hand, as usual multipath is the primary error source decreasing the efficiency of GNSS, and it has been studied experimentally in this paper.


2019 ◽  
Vol 94 ◽  
pp. 01022 ◽  
Author(s):  
Brian Bramanto ◽  
Irwan Gumilar ◽  
Muhammad Taufik ◽  
I Made D. A. Hermawan

In Indonesia, Global Navigation Satellite System (GNSS) has become one of the important tool in survey mapping, especially for cadastral purposes like land registration by using Real Time Kinematic (RTK) GNSS positioning method. The conventional RTK GNSS positioning method ensure high accuracy GNSS position solution (within several centimeters) for baseline less than 20 kilometers. The problems of resolving high accuracy position for a greater distance (more than 50 kilometers) becomes greater challenge. In longer baseline, atmospheric delays is a critical factor that influenced the positioning accuracy. In order to reduce the error, a modified LAMBDA ambiguity resolution, atmospheric correction and modified kalman filter were used in this research. Thus, this research aims to investigate the accuracy of estimated position and area in respect with short baseline RTK and differential GNSS position solution by using NAVCOM SF-3040. The results indicate that the long-range single baseline RTK accuracy vary from several centimeters to decimeters due to unresolved biases.


Author(s):  
M. Nishigaki ◽  
S. Katagiri ◽  
H. Kimura ◽  
B. Tadano

The high voltage electron microscope has many advantageous features in comparison with the ordinary electron microscope. They are a higher penetrating efficiency of the electron, low chromatic aberration, high accuracy of the selected area diffraction and so on. Thus, the high voltage electron microscope becomes an indispensable instrument for the metallurgical, polymer and biological specimen studies. The application of the instrument involves today not only basic research but routine survey in the various fields. Particularly for the latter purpose, the performance, maintenance and reliability of the microscope should be same as those of commercial ones. The authors completed a 500 kV electron microscope in 1964 and a 1,000 kV one in 1966 taking these points into consideration. The construction of our 1,000 kV electron microscope is described below.


The paper describes the main trends in the development of BIM technologies in the field of restoration and reconstruction of historical and cultural heritage buildings. The practical part of the paper presents the experience in using information modeling technologies when restoring the building, where the VI Congress of the Chinese Communist Party in Moscow took place. The use of laser scanning technologies made it possible to reproduce with high accuracy in the information model the original appearance of the building using Autodesk RevitR software. It is shown, how the use of information modeling technologies affects the duration of restoration process, taking into account the calculation of the structural scheme and bearing structures of the building, ensuring the identity of the decoration and the effective organization of electromechanical installation. Operating in a single BIM information environment makes it possible to continuously obtain reliable information on the project, which provides more effective information interaction and communication of participants compared to using traditional design methods.


Sign in / Sign up

Export Citation Format

Share Document