Ionic Liquid-Based Liquid-Liquid Microextraction for Benzodiazepine Analysis in Postmortem Blood Samples

2018 ◽  
Vol 63 (6) ◽  
pp. 1875-1879 ◽  
Author(s):  
Marieke De Boeck ◽  
Wim Dehaen ◽  
Jan Tytgat ◽  
Eva Cuypers
2015 ◽  
Vol 69 (6) ◽  
Author(s):  
Hamid Shirkhanloo ◽  
Aisan Khaligh ◽  
Hassan Zavvar Mousavi ◽  
Mohammad Mehdi Eskandari ◽  
Ali Akbar Miran-Beigi

AbstractA simple, fast, and sensitive method for speciation and determination of As (III, V) and Hg (II, R) in human blood samples based on ionic liquid-dispersive liquid-liquid microextraction (IL-DLLME) and flow injection hydride generation/cold vapor atomic absorption spectrometry (FI-HG/CV-AAS) has been developed. Tetraethylthiuram disulfide, mixed ionic liquids (hydrophobic and hydrophilic ILs) and acetone were used in the DLLME step as the chelating agent, extraction and dispersive solvents, respectively. Using a microwave assisted-UV system, organic mercury (R-Hg) was converted to Hg(II) and total mercury amount was measured in blood samples by the presented method. Total arsenic content was determined by reducing As(V) to As(III) with potassium iodide and ascorbic acid in a hydrochloric acid solution. Finally, As(V) and R-Hg were determined by mathematically subtracting the As(III) and Hg(II) content from the total arsenic and mercury, respectively. Under optimum conditions, linear range and detection limit (3σ) of 0.1-5.0 μg L


Author(s):  
Camila Scheid ◽  
Sarah Eller ◽  
Anderson Luiz Oenning ◽  
Eduardo Carasek ◽  
Josias Merib ◽  
...  

Abstract Synthetic drugs for recreational purposes are in constant evolution, and their consumption promotes a significant increase in intoxication cases, resulting in damaging public health. The development of analytical methodologies to confirm the consumption of illicit drugs in biological matrices is required for the control of these substances. This work exploited the development of an extraction method based on homogenous liquid–liquid microextraction with switchable hydrophilicity solvent (SHS) as extraction phase for the determination of the synthetic drugs 3,4-methylenedioxymethamphetamine, 3,4-methylenedioxyamphetamine and N-methoxybenzyl-methoxyphenylethylamine derivates (25B, 25C and 25I) in postmortem blood, followed by liquid chromatography coupled to mass spectrometry in tandem. The optimized sample preparation conditions consisted of using 250 µL of ZnSO4 10% and 50 µL of NaOH 1 mol/L in the protein precipitation step; N,N-dimethylcyclohexylamine was used as SHS, 650 μL of a mixture of SHS:HCl 6 mol/L (1:1 v/v), 500 μL of whole blood, 500 μL of NaOH 10 mol/L and 1 min of extraction time. The proposed method was validated, providing determination coefficients higher than 0.99 for all analytes; limit of detection and limit of quantitation ranged from 0.1 to 10 ng/mL; intra-run precision from 2.16% to 9.19%; inter-run precision from 2.39% to 9.59%; bias from 93.57% to 115.71% and matrix effects from 28.94% to 51.54%. The developed method was successfully applied to four authentic postmortem blood samples from synthetic drugs users, and it was found to be reliable with good selectivity.


2020 ◽  
Vol 16 (5) ◽  
pp. 652-659
Author(s):  
Asiye A. Avan ◽  
Hayati Filik

Background: An Ionic Liquid-based based Dispersive Liquid-Liquid Microextraction (IL-DLLME) method was not applied to preconcentration and determination of bilirubin. Ionic Liquids (ILs) are new chemical compounds. In recent years, Ionic Liquids (ILs) have been employed as alternative solvents to toxic organic solvents. Due to these perfect properties, ILs have already been applied in many analytical extraction processes, presenting high extraction yield and selectivity for analytes. Methods: In this study, IL-DLLME was applied to biological samples (urine and serum) for the spectrophotometric detection of bilirubin. For bilirubin analysis, the full-color development was based on the reaction with periodate in the presence of hydrochloric acid. The high affinity of bilirubin for the ionic liquid phase gave extraction percentages above 98% in 0.3 M HCl solution. Results: Several IL-extraction parameters were optimized and room temperature ionic liquid 1-butyl- 1-methylpyrrolidinium bis(trifluoromethylsulfonyl)imide and ethanol were used as extraction and disperser solution. The linear range was found in the range of 0.5-6.0 μM (0.3-3.5 μg mL-1) and the limits of detection of the proposed method was 0.5 μM (0.3 μg mL-1). The proposed method was applied for the preconcentration and separation of trace bilirubin in real urine samples. Also, the recoveries for bilirubin in spiked biological samples (urine and serum) were found to be acceptable, between 95-102%. Conclusion: The proposed IL-DLLMEapproach was employed for the enrichment and determination of trace levels of bilirubin in urine samples using NaIO4 as an oxidizing agent and Uv-vis spectrophotometric detection. The periodate oxidation of bilirubin is rapid, effective, selective, and simple to perform. The method contains only HCl, NaOI4, and an anionic surfactant. The method may be useful for economizing in the consumption of reagents in bilirubin determining. The IL-DLLMEmethod ensures a high yield and has a low toxicity no skin sensitization, no mutagenicity and no ecotoxicity in an aquatic environment since only very low quantities of an IL is required. For full-color formation, no any extra auxiliary reagents are required. Besides, the IL-DLLME technique uses a low-cost instrument such as Uv-vis which is present in most of the medical laboratories.


1997 ◽  
Vol 21 (7) ◽  
pp. 538-542 ◽  
Author(s):  
Michael Collins ◽  
Jenny Easson ◽  
Glyn Hansen ◽  
Allan Hodda ◽  
Keith Lewis

Sign in / Sign up

Export Citation Format

Share Document