Comparison of Different Swabs for Sampling Inorganic Gunshot Residue from Gunshot Wounds: Applicability and Reliability for the Determination of Firing Distance

2018 ◽  
Vol 64 (2) ◽  
pp. 558-564 ◽  
Author(s):  
Daniele Merli ◽  
Alberto Amadasi ◽  
Debora Mazzarelli ◽  
Annalisa Cappella ◽  
Elisa Castoldi ◽  
...  
2020 ◽  
Vol 148 (5-6) ◽  
pp. 350-356
Author(s):  
Anisa Gradascevic ◽  
Ivan Soldatovic ◽  
Anes Joguncic ◽  
Miroslav Milosevic ◽  
Nermin Sarajlic

Introduction/Objective. Gunshot residue (GSR) on the skin of a victim are important evidence, with far better precision, for reconstructive questions in the forensic investigation of cases involving gunshot wounds. The aim of this experimental study was to analyze if there was any significant difference in macroscopic characteristics of wounds that were caused with different types of weapons from three different distances. Methods. This study was conducted at the Department of Ballistic and Mechanoscopic Expertise, Federal Police Directorate. Experiments were done on pigskin and 55 samples were made. Shooting was conducted using a system for safe firing. Samples of the pigskin were shot by firing projectiles from four different weapons and from three different distances, (contact wound, five centimetres and 10 centimetres). Results. At the contact range, wounds caused by automatic rifle had horizontal, vertical diameters larger than those made by pistols. Diameters on the wounds that were caused with different pistols, were similar. At the range of five centimetres, the narrowest part of contusion ring significantly differs even through pistol wounds. Diameters at the range of 10 centimetres are in favor of these results. Gunpowder residue scattering area was statistically different depending of type of weapon (p = 0.004). Conclusion. Wound diameters and surface area are useful for differentiation between pistol and rifle caused wounds. It is unsecure method for determination of pistol caliber or fire range. GSR have much greater potential for future analyses, but even GSR cannot be used to determine pistol caliber.


1975 ◽  
Vol 29 (1) ◽  
pp. 44-48 ◽  
Author(s):  
J. A. Goleb ◽  
C. R. Midkiff

A flameless atomic absorption technique, employing a tantalum strip atomizer, has been developed to determine barium and antimony in gunshot residue. Cotton swabs, wetted with 5% HNO3, are used to collect residue. Barium and antimony are released from the swabs by acid leaching or plasma ashing. Both techniques give good recoveries; the ashing technique is preferred for blood-stained swabs. The sensitivity for barium is 0.1 ng/10 µl and antimony 0.2 ng/10 µl. At nanogram levels the standard relative deviation for barium is 8.3% and for antimony 8.5%.


2003 ◽  
Vol 138 (1-3) ◽  
pp. 68-74 ◽  
Author(s):  
T. Plattner ◽  
B. Kneubuehl ◽  
M. Thali ◽  
U. Zollinger

Sign in / Sign up

Export Citation Format

Share Document