No difference in clinical outcomes between portable navigation and conventional instrumentation in total knee arthroplasty: A randomised trial

2021 ◽  
Author(s):  
Stephen F. Ali ◽  
Monther A. Gharaibeh ◽  
Jil A. Wood ◽  
Darren B. Chen ◽  
Samuel J. MacDessi

Author(s):  
Masanori Tsubosaka ◽  
Tomoyuki Kamenaga ◽  
Yuichi Kuroda ◽  
Koji Takayama ◽  
Shingo Hashimoto ◽  
...  

AbstractSeveral studies have reported better clinical outcomes following kinematically aligned total knee arthroplasty (KA-TKA) than mechanically aligned TKA. Consistent reproduction of a KA-TKA is aided by accurate tibial bone resections using computer navigation systems. This study compares an accelerometer-based portable navigation system with a conventional navigation system on tibial bone resection and clinical outcomes in KA-TKA. This study included 60 knees of patients who underwent primary KA-TKA between May 2015 and September 2017. They were randomly assigned to the OrthoPilot and iASSIST groups. A tibial bone cut was performed with 3 degree varus and 7 degree posterior slope in relation to the mechanical axis in all cases. The tibial component angle (TCA) and posterior slope angle (PSA) were evaluated by postoperative radiography, and those that deviated more than 2 degree were set as outliers. The clinical outcomes were the knee range of motion (ROM) and 2011 Knee Society Score (KSS) evaluated at 1 year postoperation. The groups were compared in terms of the TCA, PSA, number of outliers, ROM, and 2011 KSS (p < 0.05). No significant difference was observed between the groups in terms of the mean TCA, PSA, number of outliers, ROM, and categories of the 2011 KSS (objective knee indicators, symptoms, satisfaction, expectations, and functional activities). Although tibial bone cuts were performed with 3 degree varus and 7 degree posterior slope, no significant difference was observed between the OrthoPilot and iASSIST groups in terms of the accuracy of cuts or postoperative clinical result. The iASSIST was found to be a simple and useful navigation system for KA-TKA.



2017 ◽  
Vol 32 (3) ◽  
pp. 777-782 ◽  
Author(s):  
Monther A. Gharaibeh ◽  
Gandhi N. Solayar ◽  
Ian A. Harris ◽  
Darren B. Chen ◽  
Samuel J. MacDessi


2018 ◽  
Vol 4 (3) ◽  
pp. 319-322 ◽  
Author(s):  
Hiroaki Shoji ◽  
Atsushi Teramoto ◽  
Tomoyuki Suzuki ◽  
Yohei Okada ◽  
Kota Watanabe ◽  
...  


2015 ◽  
Vol 2015 ◽  
pp. 1-8 ◽  
Author(s):  
Andrzej Kotela ◽  
Jacek Lorkowski ◽  
Marek Kucharzewski ◽  
Magdalena Wilk-Frańczuk ◽  
Zbigniew Śliwiński ◽  
...  

Total knee arthroplasty (TKA) is a frequently performed procedure in orthopaedic surgery. Recently, patient-specific instrumentation was introduced to facilitate correct positioning of implants. The aim of this study was to compare the early clinical results of TKA performed with patient-specific CT-based instrumentation and conventional technique. A prospective, randomized controlled trial on 112 patients was performed between January 2011 and December 2011. A group of 112 patients who met the inclusion and exclusion criteria were enrolled in this study and randomly assigned to an experimental or control group. The experimental group comprised 52 patients who received the Signature CT-based implant positioning system, and the control group consisted of 60 patients with conventional instrumentation. Clinical outcomes were evaluated with the KSS scale, WOMAC scale, and VAS scales to assess knee pain severity and patient satisfaction with the surgery. Specified in-hospital data were recorded. Patients were followed up for 12 months. At one year after surgery, there were no statistically significant differences between groups with respect to clinical outcomes and in-hospital data, including operative time, blood loss, hospital length of stay, intraoperative observations, and postoperative complications. Further high-quality investigations of various patient-specific systems and longer follow-up may be helpful in assessing their utility for TKA.



Author(s):  
Jung-Won Lim ◽  
Yong-Beom Park ◽  
Dong-Hoon Lee ◽  
Han-Jun Lee

AbstractThis study aimed to evaluate whether manipulation under anesthesia (MUA) affect clinical outcome including range of motion (ROM) and patient satisfaction after total knee arthroplasty (TKA). It is hypothesized that MUA improves clinical outcomes and patient satisfaction after primary TKA. This retrospective study analyzed 97 patients who underwent staged bilateral primary TKA. MUA of knee flexion more than 120 degrees was performed a week after index surgery just before operation of the opposite site. The first knees with MUA were classified as the MUA group and the second knees without MUA as the control group. ROM, Knee Society Knee Score, Knee Society Functional Score, Western Ontario and McMaster Universities (WOMAC) score, and patient satisfaction were assessed. Postoperative flexion was significantly greater in the MUA group during 6 months follow-up (6 weeks: 111.6 vs. 99.8 degrees, p < 0.001; 3 months: 115.9 vs. 110.2 degrees, p = 0.001; 6 months: 120.2 vs. 117.0 degrees, p = 0.019). Clinical outcomes also showed similar results with knee flexion during 2 years follow-up. Patient satisfaction was significantly high in the MUA group during 12 months (3 months: 80.2 vs. 71.5, p < 0.001; 6 months: 85.8 vs. 79.8, p < 0.001; 12 months: 86.1 vs. 83.9, p < 0.001; 24 months: 86.6 vs. 85.5, p = 0.013). MUA yielded improvement of clinical outcomes including ROM, and patient satisfaction, especially in the early period after TKA. MUA in the first knee could be taken into account to obtain early recovery and to improve patient satisfaction in staged bilateral TKA.



Author(s):  
Nicola Pizza ◽  
Stefano Di Paolo ◽  
Raffaele Zinno ◽  
Giulio Maria Marcheggiani Muccioli ◽  
Piero Agostinone ◽  
...  

Abstract Purpose To investigate if postoperative clinical outcomes correlate with specific kinematic patterns after total knee arthroplasty (TKA) surgery. The hypothesis was that the group of patients with higher clinical outcomes would have shown postoperative medial pivot kinematics, while the group of patients with lower clinical outcomes would have not. Methods 52 patients undergoing TKA surgery were prospectively evaluated at least a year of follow-up (13.5 ± 6.8 months) through clinical and functional Knee Society Score (KSS), and kinematically through dynamic radiostereometric analysis (RSA) during a sit-to-stand motor task. Patients received posterior-stabilized TKA design. Based on the result of the KSS, patients were divided into two groups: “KSS > 70 group”, patients with a good-to-excellent score (93.1 ± 6.8 points, n = 44); “KSS < 70 group”, patients with a fair-to-poor score (53.3 ± 18.3 points, n = 8). The anteroposterior (AP) low point (lowest femorotibial contact points) translation of medial and lateral femoral compartments was compared through Student’s t test (p < 0.05). Results Low point AP translation of the medial compartment was significantly lower (p < 0.05) than the lateral one in both the KSS > 70 (6.1 mm ± 4.4 mm vs 10.7 mm ± 4.6 mm) and the KSS < 70 groups (2.7 mm ± 3.5 mm vs 11.0 mm ± 5.6 mm). Furthermore, the AP translation of the lateral femoral compartment was not significantly different (p > 0.05) between the two groups, while the AP translation of the medial femoral compartment was significantly higher for the KSS > 70 group (p = 0.0442). Conclusion In the group of patients with a postoperative KSS < 70, the medial compartment translation was almost one-fourth of the lateral one. Surgeons should be aware that an over-constrained kinematic of the medial compartment might lead to lower clinical outcomes. Level of evidence II.



Author(s):  
Omer Ayik ◽  
Mehmet Demirel ◽  
Fevzi Birisik ◽  
Ali Ersen ◽  
Halil I. Balci ◽  
...  

AbstractThe present randomized controlled study aims to evaluate whether tourniquet application during total knee arthroplasty (TKA) has an effect on (1) thigh muscle strength (quadriceps and hamstring muscle strength) and (2) clinical outcomes (postoperative knee range of motion [ROM], postoperative pain level, and Knee Society Score [KSS]). The effects of tourniquet application during TKA were investigated in 65 patients randomly allocated to one of two groups: TKA with a tourniquet and TKA without a tourniquet. Patients in both groups were comparable in terms of the demographic and clinical data (p > 0.05 for age, number of patients, sex, radiographic gonarthrosis grade, American Society of Anesthesiologists [ASA] classification, and body mass index [BMI]). All patients in both groups were operated by the same surgeon using one type of prosthesis. Isokinetic muscle strength (peak torque and total work) of knee extensors (quadriceps) and flexors (hamstrings) was measured in Newton meters (Nm) using a CYBEX 350 isokinetic dynamometer (HUMAC/CYBEX 2009, Stoughton, MA). The combined KSS (knee score + function score), visual analog scale (VAS), and knee ROM were measured preoperatively and at 1 and 3 months postoperatively to evaluate clinical outcomes. There were no significant differences between the two groups in preoperative and postoperative values of isokinetic muscle strength (peak torque and total work) and aforementioned clinical outcomes (p < 0.05). The present study has shown that quadriceps strength and clinical outcomes were not improved in the early postoperative period (3 months) when a tourniquet was not used during TKA.



Sign in / Sign up

Export Citation Format

Share Document