Blalock-Taussig shunt versus patent ductus arteriosus stent as first palliation for ductal-dependent pulmonary circulation lesions: A review of the literature

2019 ◽  
Vol 14 (1) ◽  
pp. 105-109 ◽  
Author(s):  
Dana M. Boucek ◽  
Athar M. Qureshi ◽  
Bryan H. Goldstein ◽  
Christopher J. Petit ◽  
Andrew C. Glatz
Author(s):  
Kanishka Ratnayaka ◽  
Stephen J. Nageotte ◽  
John W. Moore ◽  
Peter W. Guyon ◽  
Krishna Bhandari ◽  
...  

Background: Ductal-dependent cyanotic newborns require a secure source of pulmonary blood flow. There has been a recent migration to selective ductal (patent ductus arteriosus [PDA]) stenting for some of these children. Universal (nonselective) ductal stenting for all infants with ductal-dependent pulmonary blood flow is controversial. We examine outcomes from a single center with this practice change. Methods: We compare outcomes of all ductal-dependent pulmonary blood flow infants (2013–2020 [January–June]) in the following treatment eras: Era 1 (selective PDA stenting; 2013–2017) or Era 2 (universal PDA stenting; 2018–2020 [January–June]). Results: Eighty-eight patients (Blalock-Taussig shunt, n=41; PDA stent, n=47) met inclusion criteria. In Era 1, most received Blalock-Taussig shunt (62% [41/66]). In Era 2, all received PDA stents (100% [22/22]). There were more females in Era 2, but otherwise no demographic differences between eras. There were no differences in mortality, treatment failures, complications, or reinterventions between eras. Postprocedure length of stay was shorter in Era 2 (8 versus 22 days, P =0.02). There were less surgical revisions for PDA stent patients (2% versus 20%, P =0.02). Postprocedure recovery surrogate end points favored Era 2 and PDA stenting. Additional analysis revealed PDA stent (compared with Blalock-Taussig shunt) patients had shorter post-procedure (10 versus 29 days, P ≤0.001) length of stay and more symmetrical branch pulmonary arteries (0.9 versus 0.7, P =0.001) at subsequent surgery. Conclusions: PDA stenting for almost all ductal dependent cyanotic newborns can be safe and effective and may have lower morbidity than selective PDA stenting.


2021 ◽  
Vol 12 ◽  
Author(s):  
Jiwen Xiong ◽  
Qi Sun ◽  
Yi Qian ◽  
Liwei Hu ◽  
Zhirong Tong ◽  
...  

The question of preserving the patent ductus arteriosus (PDA) during the modified Blalock–Taussig shunt (MBTS) procedure remains controversial. The goal of this study was to investigate the effects of the PDA on the flow features of the MBTS to help with preoperative surgery design and postoperative prediction. In this study, a patient with pulmonary atresia and PDA was included. A patient-specific three-dimensional model was reconstructed, and virtual surgeries of shunt insertion and ductus ligation were performed using computer-aided design. Computational fluid dynamics was utilized to analyze the hemodynamic parameters of varied models based on the patient-specific anatomy and physiological data. The preservation of the PDA competitively reduced the shunt flow but increased total pulmonary perfusion. The shunt flow and ductal flow collided, causing significant and complicated turbulence in the pulmonary artery where low wall shear stress, high oscillatory shear index, and high relative residence time were distributed. The highest energy loss was found when the PDA was preserved. The preservation of PDA is not recommended during MBTS procedures because it negatively influences hemodynamics. This may lead to pulmonary overperfusion, inadequate systemic perfusion, and a heavier cardiac burden, thus increasing the risk of heart failure. Also, it seems to bring no benefit in terms of reducing the risk for thrombosis.


PEDIATRICS ◽  
1953 ◽  
Vol 12 (3) ◽  
pp. 259-262
Author(s):  
VICTOR ALZAMORA ◽  
ANDRÉS ROTTA ◽  
GUIDO BATTILANA ◽  
RICARDO ABUGATTAS ◽  
CARLOS RUBIO ◽  
...  

Over a period of 8 years, 176 cases of cardiac anomalies have been found in over 10,000 consecutive admissions. The place of birth and its altitude have been recorded for each one of these causes. Patent ductus arteriosus and persistent interatrial communications are more likely to be found in patients born at high altitudes. It is suggested, but remains to be shown, that this is true for defects of the pulmonary artery. No apparent relation could be found in this series for other malformations. It is presumed that mechanical factors tied to the pulmonary circulation and the lower oxygen tension both have a decisive influence.