Determination of fatty acid methyl esters in cosmetic castor oils by flow injection-electrospray ionization-high-resolution mass spectrometry

2018 ◽  
Vol 40 (3) ◽  
pp. 295-302 ◽  
Author(s):  
M. A. Arroyo Negrete ◽  
K. Wrobel ◽  
F. J. Acevedo Aguilar ◽  
E. Yanez Barrientos ◽  
A. R. Corrales Escobosa ◽  
...  
2010 ◽  
Vol 88 (9) ◽  
pp. 898-905 ◽  
Author(s):  
Liyan Liu ◽  
Ying Li ◽  
Rennan Feng ◽  
Changhao Sun

A method for simultaneous determination of 16 free fatty acids (FFAs) in serum is described. The method involves conversion of FFAs to fatty acid methyl esters (FAMEs) using the heat of ultrasonic waves followed by gas chromatography and mass spectrometry (GC–MS) analysis. Optimum levels of the variables affecting the yield of FAMEs were investigated. The results indicate that the optimal levels are 55 °C, 60 W, 10% H2SO4/CH3OH, and 50 min. Recoveries ranged from 85.32% to 112.11%, with a detection limit ranging from 0.03 to 0.08 μg mL–1. The linearity, using the linear correlation coefficient, was higher than 0.9914.


2020 ◽  
Vol 86 (8) ◽  
pp. 23-31
Author(s):  
V. G. Amelin ◽  
D. S. Bolshakov

The goal of the study is developing a methodology for determination of the residual amounts of quaternary ammonium compounds (QAC) in food products by UHPLC/high-resolution mass spectrometry after water-acetonitrile extraction of the determined components from the analyzed samples. The identification and determination of QAC was carried out on an «UltiMate 3000» ultra-high-performance liquid chromatograph (Thermo Scientific, USA) equipped with a «maXis 4G» high-resolution quadrupole-time-of-flight mass spectrometric detector and an ion spray «ionBooster» source (Bruker Daltonics, Germany). Samples of milk, cheese (upper cortical layer), dumplings, pork, chicken skin and ground beef were used as working samples. Optimal conditions are specified for chromatographic separation of the mixture of five QAC, two of them being a mixture of homologues with a linear structure (including isomeric forms). The identification of QAC is carried out by the retention time, exact mass of the ions, and coincidence of the mSigma isotopic distribution. The limits for QAC detection are 0.1 – 0.5 ng/ml, the determination limits are 1 ng/ml for aqueous standard solutions. The determinable content of QAC in food products ranges within 1 – 100 ng/g. The results of analysis revealed the residual amount of QAC present in all samples, which confirms data of numerous sources of information about active use of QAC-based disinfectants in the meat and dairy industry. The correctness of the obtained results is verified by introduction of the additives in food products at a level of 10 ng/g for each QAC. The relative standard deviation of the analysis results does not exceed 0.18. The duration of the analysis is 30 – 40 min.


Sign in / Sign up

Export Citation Format

Share Document