scholarly journals Automated versus manual blood pressure measurement: A randomized crossover trial

2008 ◽  
Vol 14 (4) ◽  
pp. 296-302 ◽  
Author(s):  
Megan Heinemann ◽  
Ken Sellick ◽  
Claire Rickard ◽  
Pam Reynolds ◽  
Matthew McGrail
Author(s):  
Mehmet Fatih Yılmaz ◽  
Sedat Kalkan

Objectives: The aim of the study is to evaluate the quality and reliability of videos on manual blood pressure measurement on Youtube. Patients and Methods: In January 2021, the first 100 videos found as a result of a search with the keywords 'manual blood pressure measurement' on Youtube were watched and evaluated. According to exclusion criteria, 75 videos were included in the study. Duplicate videos, irrelevant videos, and videos in languages other than English were excluded from the study. Each video was scored according to the questions prepared based on the guidelines. The GQS score and the 'Reliability' score were used to assess the quality of the videos. Results: According to the checklist prepared according to the hypertension consensus report, the mean score of the videos was 8.33 ± 2.1. When the videos were evaluated according to their sources, the average score of the videos of the health sites was 9±2.5, the average score of the videos of the individual health workers was 8.66±1.8, the average score of the videos of the unidentified people was 7.54±2.1. Conclusion: Manual blood pressure measurement videos on Youtube have little educational value. Videos of health websites should be preferred for education.


2019 ◽  
Vol 27 (1) ◽  
pp. 114-125 ◽  
Author(s):  
Esther J. Varney ◽  
Ashley M. Van Drunen ◽  
Emily F. Moore ◽  
Kristen Carlin ◽  
Karen Thomas

Background and PurposeBlood pressure measurement represents the pressure exerted during heart ejection and filling. There are several ways to measure blood pressure and a valid measure is essential. The purpose of this study was to evaluate the approach to noninvasive blood pressure measurement in children.MethodsBlood pressure measurements were taken using the automatic Phillips MP30 monitor and compared against Welch Allyn blood pressure cuffs with Medline manual sphygmomanometers.ResultsA total of 492 measurements were taken on 82 subjects, and they demonstrated comparability between automatic and manual devices.ConclusionsAlthough our study indicated acceptable agreement between automatic and manual blood pressure measurement, it also revealed measurement error remains a concern, with sample size, study protocol, training, and environment all playing a role.


2016 ◽  
Vol 4 (3) ◽  
pp. 404-409 ◽  
Author(s):  
Kanaan Mansoor ◽  
Saba Shahnawaz ◽  
Mariam Rasool ◽  
Huwad Chaudhry ◽  
Gul Ahuja ◽  
...  

BACKGROUND: Hypertension has proven to be a strong liability with 13.5% of all mortality worldwide being attributed to elevated blood pressures in 2001. An accurate blood pressure measurement lies at the crux of an appropriate diagnosis. Despite the mercury sphygmomanometer being the gold standard, the ongoing deliberation as to whether mercury sphygmomanometers should be replaced with the automated oscillometric devices stems from the risk mercury poses to the environment.AIM: This study was performed to check the validity of automated oscillometric blood pressure measurements as compared to the manual blood pressure measurements in Karachi, Pakistan.MATERIAL AND METHODS: Blood pressure was recorded in 200 individuals aged 15 and above using both, an automated oscillometric blood pressure device (Dinamap Procare 100) and a manual mercury sphygmomanometer concomitantly. Two nurses were assigned to each patient and the device, arm for taking the reading and nurses were randomly determined. SPSS version 20 was used for analysis. Mean and standard deviation of the systolic and diastolic measurements from each modality were compared to each other and P values of 0.05 or less were considered to be significant. Validation criteria of British Hypertension Society (BHS) and the US Association for the Advancement of Medical Instrumentation (AAMI) were used. RESULTS: Two hundred patients were included. The mean of the difference of systolic was 8.54 ± 9.38 while the mean of the difference of diastolic was 4.21 ± 7.88. Patients were further divided into three groups of different systolic blood pressure <= 120, > 120 to = 150 and > 150, their means were 6.27 ± 8.39 (p-value 0.175), 8.91 ± 8.96 (p-value 0.004) and 10.98 ± 10.49 (p-value 0.001) respectively. In our study 89 patients were previously diagnosed with hypertension; their difference of mean systolic was 9.43 ± 9.89 (p-value 0.000) and difference of mean diastolic was 4.26 ± 7.35 (p-value 0.000).CONCLUSIONS: Systolic readings from a previously validated device are not reliable when used in the ER and they show a higher degree of incongruency and inaccuracy when they are used outside validation settings. Also, readings from the right arm tend to be more precise.


Author(s):  
Lucy (Neinguii) Suokhrie ◽  
Carole-Rae Reed ◽  
Carolyn Emory ◽  
Rosemarie White ◽  
Carol T. Moriarity ◽  
...  

2014 ◽  
Vol 2014 ◽  
pp. 1-8 ◽  
Author(s):  
Sara Ribezzo ◽  
Eleonora Spina ◽  
Stefano Di Bartolomeo ◽  
Gianfranco Sanson

Introduction.Noninvasive blood pressure (NIBP) monitoring methods are widely used in critically ill patients despite poor evidence of their accuracy. The erroneous interpretations of blood pressure (BP) may lead to clinical errors.Objectives.To test the accuracy and reliability of aneroid (ABP) and oscillometric (OBP) devices compared to the invasive BP (IBP) monitoring in an ICU population.Materials and Methods.Fifty adult patients (200 comparisons) were included in a randomized crossover trial. BP was recorded simultaneously by IBP and either by ABP or by OBP, taking IBP as gold standard.Results.Compared with ABP, IBP systolic values were significantly higher (mean difference ± standard deviation9.74±13.8;P<0.0001). Both diastolic (-5.13±7.1;P<0.0001) and mean (-2.14±7.1;P=0.0033) IBP were instead lower. Compared with OBP, systolic (10.80±14.9;P<0.0001) and mean (5.36±7.1;P<0.0001) IBP were higher, while diastolic IBP (-3.62±6.0;P<0.0001) was lower. Bland-Altman plots showed wide limits of agreement in both NIBP-IBP comparisons.Conclusions.BP measurements with different devices produced significantly different results. Since in critically ill patients the importance of BP readings is often crucial, noninvasive techniques cannot be regarded as reliable alternatives to direct measurements.


2019 ◽  
Vol 32 (4) ◽  
pp. 498-501
Author(s):  
Bryce C. Rhodehouse ◽  
Jerry Fan ◽  
Wencong Chen ◽  
Michael J. McNeal ◽  
Charis G. Durham ◽  
...  