Near-Infrared Spectroscopy for Plaque Characterization

2008 ◽  
Vol 21 (6) ◽  
pp. 452-458 ◽  
Author(s):  
SERGIO WAXMAN
2016 ◽  
Vol 2016 ◽  
pp. 1-9
Author(s):  
Elżbieta Pociask ◽  
Joanna Jaworek-Korjakowska ◽  
Krzysztof Piotr Malinowski ◽  
Tomasz Roleder ◽  
Wojciech Wojakowski

Background. Detecting and identifying vulnerable plaque, which is prone to rupture, is still a challenge for cardiologist. Such lipid core-containing plaque is still not identifiable by everyday angiography, thus triggering the need to develop a new tool where NIRS-IVUS can visualize plaque characterization in terms of its chemical and morphologic characteristic. The new tool can lead to the development of new methods of interpreting the newly obtained data. In this study, the algorithm to fully automated lipid pool detection on NIRS images is proposed. Method. Designed algorithm is divided into four stages: preprocessing (image enhancement), segmentation of artifacts, detection of lipid areas, and calculation of Lipid Core Burden Index. Results. A total of 31 NIRS chemograms were analyzed by two methods. The metrics, total LCBI, maximal LCBI in 4 mm blocks, and maximal LCBI in 2 mm blocks, were calculated to compare presented algorithm with commercial available system. Both intraclass correlation (ICC) and Bland-Altman plots showed good agreement and correlation between used methods. Conclusions. Proposed algorithm is fully automated lipid pool detection on near infrared spectroscopy images. It is a tool developed for offline data analysis, which could be easily augmented for newer functions and projects.


2008 ◽  
Vol 39 (01) ◽  
Author(s):  
AJ Fallgatter ◽  
AC Ehlis ◽  
MM Richter ◽  
M Schecklmann ◽  
MM Plichta

Author(s):  
S. Srilekha ◽  
B. Vanathi

This paper focuses on electroencephalography (EEG) and functional near-infrared spectroscopy (fNIRS) comparison to help the rehabilitation patients. Both methods have unique techniques and placement of electrodes. Usage of signals are different in application based on the economic conditions. This study helps in choosing the signal for the betterment of analysis. Ten healthy subject datasets of EEG & FNIRS are taken and applied to plot topography separately. Accuracy, Sensitivity, peaks, integral areas, etc are compared and plotted. The main advantages of this study are to prompt their necessities in the analysis of rehabilitation devices to manage their life as a typical individual.


Sign in / Sign up

Export Citation Format

Share Document