Use of Geochemical Reference Materials in a Quality Control/Quality Assurance Program*

1991 ◽  
Vol 15 (1) ◽  
pp. 23-31 ◽  
Author(s):  
Wesley M. JOHNSON
1985 ◽  
Vol 31 (2) ◽  
pp. 261-263 ◽  
Author(s):  
A Hainline ◽  
P Hill ◽  
L Garbaczewski ◽  
C Winn

Abstract A special standardization and quality assurance program, similar to that created for the Lipid Research Clinics Program (LRC), was developed for the American Health Foundation Laboratory by the Centers for Disease Control (CDC) to assure the quality of lipid measurements in the U.S. Air Force Health Evaluation and Risk Tabulation (HEART) Program. This study was designed to test the feasibility of reducing the incidence of heart disease in active-duty U.S. Air Force personnel through life-study intervention. During the 18-month study, CDC provided serum calibrators and reference materials for internal control and an external surveillance program for measurements of total cholesterol (TC) and high-density-lipoprotein cholesterol (HDLC). The Laboratory, using an automated enzymic method to measure cholesterol, achieved an overall goal for accuracy of less than 2% error (av systematic error, -30.6 mg/L) for TC, as measured on nine reference pools for which values were assigned by CDC. The average bias of measurements of HDLC with heparin-manganese to separate the lipoproteins in five CDC reference pools was -4.6 mg/L. Bias was estimated relative to the values assigned to the reference materials by the CDC reference methods for TC and HDLC. The average CV for TC was 0.89%, for HDLC 2.66%. Accuracy of cholesterol measurements can be assured over time with a standardization and quality-assurance program that incorporates accurately labeled reference materials for calibration, internal quality control, and external surveillance.


Author(s):  
Robert P. Elliott ◽  
Yanjun Qiu

A common provision in quality control/quality assurance construction contracts is the adjustment of the contractor's pay on the basis of the quality of the construction. The expected impact of the provision on the pay should be examined to ensure that the adjustments are neither unduly severe nor excessively lenient. Most pay adjustment plans have been developed around a quality index by using a percent defective approach. Analyses of these plans are complex but reasonably well defined. Other plans, however, are more complex and do not lend themselves to direct analysis. These plans can be examined by computer simulation. The use of computer simulation to examine a complex pay adjustment provision is demonstrated. The analyses show that simulation can reveal that a pay adjustment schedule behaves differently than it appears on the surface. For example, the schedule examined bases pay solely on averages and appears to ignore construction variability. The analyses, however, demonstrate that the pay adjustments are at least as sensitive to construction variability as they are to construction averages. It is also shown that the simulation process can provide a better, more detailed examination of the pay schedule than is possible by simply determining the expected pay. In particular, the simulation process can provide an indication of the variability of pay at various quality levels and can identify the factors most responsible for pay adjustments.


2001 ◽  
Vol 84 (6) ◽  
pp. 1786-1792 ◽  
Author(s):  
Philippe Quevauviller

Abstract Reference materials represent an invaluable tool for analytical quality control. Certified Reference Materials (CRMs) are used for the validation of methods, whereas various types of (uncertified) Reference Materials (RMs) are used for routine quality control (establishment of control charts) and interlaboratory testing (e.g., proficiency testing). This paper provides background information on the production and use of environmental RMs and describes recent CRMs produced by the BCR (European Commission) for quality assurance in environmental analysis.


Sign in / Sign up

Export Citation Format

Share Document