Hands‐free continuous transthoracic echocardiography: A contemporary evolution of the precordial stethoscope

2021 ◽  
Author(s):  
Walid Alrayashi ◽  
Stephen Kelleher ◽  
James DiNardo ◽  
Pete Kovatsis ◽  
William Clarke ◽  
...  
Author(s):  
Rafael Antonio Caldart Bedin ◽  
Maisa Schultz ◽  
Antonio Bedin

Anesthesia for laboratory animals is a matter of biomedical concern and one of the most present dilemmas in the current bioethical debate. The use of anesthetic agents in experimental surgery aims at analgesia and restraining the animal, in order to achieve a reasonable degree of muscle relaxation and to produce sufficient analgesia. This practice requires the use of protocols for the administration of safe and efficient doses. Eight New Zealand rabbits were submitted to laparotomies demonstrating the surgical technique discipline of the local medical course. For pre-anesthetic medication, acepromazine 1 mg.kg-1 associated with ketamine 15 mg.kg-1 was used subcutaneously. Anesthesia was maintained with isoflurane and oxygen under a laryngeal mask in a Mapleson D anesthesia system and under spontaneous breathing. Hydration was performed with 10 ml.kg-1 saline every hour. A thermal mattress was used. Precordial stethoscope, pulse oximetry and clinical parameters were used for monitoring. For euthanasia, ketamine 10 mg.kg-1 associated with potassium chloride 19.1% 1 ml.kg-1 was used intravenously. The average weight of the rabbits was 2721.25 ± 275.01 grams and the duration of the anesthetic procedure was 120 ± 87 minutes. Discussion. In long-term anesthesia, such as laparotomies, the use of pre-anesthetic medication and then anesthetic induction by the combination of agents is recommended. However, anesthetic management requires monitoring to prevent insufficient or excessive doses from occurring.


2018 ◽  
pp. 26-35
Author(s):  
Z. A. Agaeva ◽  
K. B. Baghdasaryan

The transthoracic echocardiography made by multifrequency probes with support of the mode of the second harmonic imaging, is a competitive method for visualization of the main coronary arteries and allows to estimate coronary blood flow with high quality. Of course, the method has considerable restrictions, most important of which is the low spatial resolution of a method, due to small acoustic window. Because of this the transthoracic visualization of coronary arteries perhaps will not become the leading method of anatomic reconstruction of separately taken coronary artery and especially all coronary arteries system. However uniqueness and indisputable advantage of this method is an opportunity to noninvasively estimate a coronary blood flow both once, and in dynamics.


Choonpa Igaku ◽  
2011 ◽  
Vol 38 (4) ◽  
pp. 461-464
Author(s):  
Koutatsu NOMURA ◽  
Yoshikazu YAZAKI ◽  
Masako MIYASHITA ◽  
Sachiko OOTSUKI ◽  
Yutaka KUMAGAI ◽  
...  

2015 ◽  
pp. 77-82
Author(s):  
Ba Minh Du Le ◽  
Anh Vu Nguyen ◽  
Duc Phu Bui

Background and aim of the study: Mitral repair is now as the treatement of choice in patients suffering mitral regurgitation due to mitral valve prolapse or flail. However, mitral valve repair demands the mitral valve morphology being feasible for repair. The study aims at evaluating transthoracic and transesophageal echocardiographic features in consecutive patients with mitral valve prolapse or flail undergoing surgical repair at Hue Central Hospital. The correlation between preoperative and intraoperative echocardiographic features and surgical findings in these patients. These echocardiographic data may predict the surgical outcome. Methods: From December 2010 to January 2013, 73 patients (37 men, 36 women; average age 37.5) were recruited into the study. All patients had degenerative mitral valve disease causing important regurgitation and underwent systematic preoperative transthoracic echocardiography, preoperative and intraoperative transesophageal echocardiography for delineation of six segments (scallops) of anterior and posterior leaflets. Results: Among 73 patients, 64 patients were in fibroelastic deficiency (87.7%) and 9 patients suffered Barlow disease (12.3%). Mitral valve repair was performed in 52 patients (71.2%) and mitral replacement was performed in 21 patients (28.8%). All 52 mitral valve repair (81.3%) and 12 mitral valve replacement (18.7%) was performed in fibroelastic deficiency patients. All 9 Barlow patients must undergo mitral valve replacement (100%). A prolapse or flail of mitral valve in 73 patients was documented by transthoracic and transesophageal echocardiography and confirmed on surgical inspection. Accuracy of transthoracic echocardiography was (89.0%) and accuracy of transesophageal echocardiography was (91.8%) in identifying mitral valve segments prolapse or flail. Success rate of mitral valve repair was (98.0%) in prolapse of 1 or 2 segments, but was low (36.0%) in prolapse > 3 segments. Success rate of mitral valve repair was (96.6%) in prolapse of posterior leaflet, but was (63.6%) in prolapse anterior leaflet or bileaflet. Conclusion: - Mitral valve repair was favorable in fibroelastic deficiency patients, but difficult in Barlow patients. - Accuracy of transthoracic and transesophageal echocardiography was high in identifying mitral valve segments prolapse or flail. - Success rate of mitral valve repair was high in prolapse of 1 or 2 segments. - Success rate of mitral valve repair was high in in prolapse of posterior leaflet. Key words: Mitral repair, echocardiography, degenerative, Barlow, fibroelastic deficiency, prolapse, flail


2019 ◽  
Vol 0 (0) ◽  
pp. 0-0
Author(s):  
Atef Elrifai ◽  
Sayed kinawy ◽  
Naggeh Mahmoud ◽  
Muhammad Reihan

Sign in / Sign up

Export Citation Format