Vibration Behavior of Rotated Triangular Tube Bundles in Two-Phase Cross Flows

2002 ◽  
Vol 124 (2) ◽  
pp. 144-153 ◽  
Author(s):  
M. J. Pettigrew ◽  
C. E. Taylor ◽  
V. P. Janzen ◽  
T. Whan

The results of a series of tests describing the vibration behavior of several rotated triangular tube bundles subjected to two-phase cross flows are presented. Tube bundles with a pitch-to-diameter ratio of approximately 1.5 were tested over a broad range of void fractions and mass fluxes. Fluidelastic instability, random turbulence excitation, hydrodynamic mass, two-phase damping and local void-fraction were investigated. Well-defined fluidelastic instabilities were observed in continuous two-phase flow regimes. However, intermittent two-phase flow regimes had a dramatic effect on fluidelastic instability leading to lower than expected threshold flow velocities for instability. This effect was more pronounced in Freon two-phase flow than in air-water, and appeared well correlated to the transition between continuous and intermittent flow regimes. Generally, random turbulence excitation forces were much lower in Freon than in air-water. Although very dependent on void fraction, as expected, damping was quite similar in air-water and Freon.

1995 ◽  
Vol 117 (4) ◽  
pp. 321-329 ◽  
Author(s):  
M. J. Pettigrew ◽  
C. E. Taylor ◽  
J. H. Jong ◽  
I. G. Currie

Two-phase cross-flow exists in many shell-and-tube heat exchangers. The U-bend region of nuclear steam generators is a prime example. Testing in two-phase flow simulated by air-water provides useful results inexpensively. However, two-phase flow parameters, in particular surface tension and density ratio, are considerably different in air-water than in steam-water. A reasonable compromise is testing in liquid-vapor Freon, which is much closer to steam-water while much simpler experimentally. This paper presents the first results of a series of tests on the vibration behavior of tube bundles subjected to two-phase Freon cross-flow. A rotated triangular tube bundle of tube-to-diameter ratio of 1.5 was tested over a broad range of void fractions and mass fluxes. Fluidelastic instability, random turbulence excitation, and damping were investigated. Well-defined fluidelastic instabilities were observed in continuous two-phase flow regimes. However, intermittent two-phase flow regimes had a dramatic effect on fluidelastic instability. Generally, random turbulence excitation forces are much lower in Freon than in air-water. Damping is very dependent on void fraction, as expected.


1995 ◽  
Vol 119 (3) ◽  
pp. 182-194 ◽  
Author(s):  
S. M. Ghiaasiaan ◽  
K. E. Taylor ◽  
B. K. Kamboj ◽  
S. I. Abdel-Khalik

2021 ◽  
Vol 321 ◽  
pp. 01002
Author(s):  
Claire Dubot ◽  
Vincent Melot ◽  
Claudine Béghein ◽  
Cyrille Allery ◽  
Clément Bonneau

Being able to predict the void fraction is essential for a numerical prediction of the thermohydraulic behaviour in steam generators. Indeed, it determines two-phase mixture density and affects two-phase mixture velocity which enable to evaluate the pressure drop of heat exchanger, the mass transfer and heat transfer coefficients. In this study, the flow is modelled by coupling Ansys Fluent with an in-house code library where a CFD porous media approach is implemented. In this code, the two-phase flow has been modelled so far using the Eulerian model. However, this two-phase model requires interaction laws between phases which are not known and/or reliable for a flow within a tube bundle. The aim of this paper is to use the mixture model, for which it is easier to implement suitable correlations for tube bundles. By expressing the relative velocity, as a function of slip, the void fraction model of Feenstra et al. developed for upward cross-flow through horizontal tube bundles is introduced. With this method, physical phenomena that occur in tube bundles are taken into consideration in the mixture model. The developed approach is validated based on the experimental results obtained by Dowlati et al.


2005 ◽  
Vol 4 (2) ◽  
Author(s):  
G. Ribatskia ◽  
J. R. Thome

This paper presents a state-of-the-art review of the hydrodynamic aspects of two-phase flow across horizontal tube bundles. The review covers studies related to the evaluation of void fraction, two-phase flow behaviors and pressure drops on the shell side of staggered and in-line tube bundles for upward, downward and side-to-side flows. This study of the literature critically describes the proposed flow pattern maps and semi-empirical correlations for predicting void fraction and frictional pressure drop. These predicting methods are generally based on experimental results for adiabatic air-water flows. A limited number of experimental studies with R-11 and R-113 were also carried out in the past. The review shows noticeable discrepancies among the available prediction methods. Finally, this study suggests that further research focusing on the development of representative databanks and new prediction methods is still necessary.


2008 ◽  
Author(s):  
Mohammad A. Rahman ◽  
Johana Gomez ◽  
Ted Heidrick ◽  
Brian A. Fleck ◽  
Jennifer McMillan

Experimentally accurate void fraction measurements are a challenge in an air/water, two-phase flows through an industrial nozzle assembly, as a highly non-uniform void fraction exists in the feeding conduit prior to the nozzle. In this study, average void fractions were measured by isolating a section in the feeding conduit of a horizontal nozzle assembly, termed as the quick-closing-valve (QCV) technique. A high-speed video camera was utilized to capture the asynchronization closing time, tac. The average closing time and asynchronization for the pneumatically controlled valves were 200 ms and 2 ms, respectively. Based on the equation of 100umtac (1−α)/αlc, the synchronization error between the two valves was 1.12%, 1.26%, and 1.79% for the 1%, 2% and 4% ALR cases, respectively; here um is the mixture velocity, α is the void faction, and lc is the closing length. Higher synchronization error at 4% ALR occurs due to enhanced momentum in the flow regime. Experimental results indicate that the average α over the 33.4 cm feeding conduit (6.25 mm ID) was 76% (αtheoretical = 75%) for the 2% ALR, and 85% (αtheoretical = 83%) for the 3.3% ALR. In the two-phase, two-component flow the α affects the drop size and stability of the spray produced from an industrial nozzle assembly. Learning from this study will yield insights and conceptual understanding of two-phase flow phenomena in conduit, which would affect stability, pulsation tendency, and possibly atomization performance of the nozzle downstream. Two-phase flow nozzles have wide applications in the industries, e.g. petrochemical, pharmaceutical, and others.


Author(s):  
Shao-Wen Chen ◽  
Caleb S. Brooks ◽  
Chris Macke ◽  
Takashi Hibiki ◽  
Mamoru Ishii ◽  
...  

In order to investigate the possible effect of seismic vibration on two-phase flow dynamics and thermal-hydraulics of a nuclear reactor, experimental tests of adiabatic air-water two-phase flow under low-frequency vibration were carried out in this study. An eccentric cam vibration module operated at low motor speed (up to 390rpm) was attached to an annulus test section which was scaled down from a prototypic BWR fuel assembly sub-channel. The inner and outer diameters of the annulus are 19.1mm and 38.1mm, respectively. The two-phase flow operating conditions cover the ranges of 0.03≤<jg> ≤1.46m/s and 0.25≤<jf>≤1.00m/s and the vibration displacement ranges from ±0.8mm to ±22.2mm. Steady-state area-averaged instantaneous and time-averaged void fraction was recorded and analyzed in stationary and vibration experiments. A neural network flow regime identification technique and fast Fourier transformation (FFT) analysis were introduced to analyze the flow regimes and void signals under stationary and vibration conditions. Experimental results reveal possible changes in flow regimes under specific flow and vibration conditions. In addition, the instantaneous void fraction signals were affected and shown by FFT analysis. Possible reasons for the changes include the applied high acceleration and/or induced resonance at certain ports under the specific flow and vibration conditions.


Author(s):  
Teguewinde Sawadogo ◽  
Njuki Mureithi

The time delay is a key parameter for modeling fluidelastic instability, especially the damping controlled mechanism. It can be determined experimentally by measuring directly the time lag between the tube motion and the induced fluid forces. The fluid forces may be obtained by integrating the pressure field around the moving tube. However, this method faces certain difficulties in two-phase flow since the high turbulence and the non-uniformity of the flow may increase the randomness of the measured force. To overcome this difficulty, an innovative method for extracting the time delay inherent to the quasi-steady model for fluidelastic instability is proposed in this study. Firstly, experimental measurements of unsteady and quasi-static fluid forces (in the lift direction) acting on a tube subject to two-phase flow were conducted. The unsteady fluid forces were measured by exciting the tube using a linear motor. These forces were measured for a wide range of void fraction, flow velocities and excitation frequencies. The experimental results showed that the unsteady fluid forces could be represented as single valued function of the reduced velocity (flow velocity reduced by the excitation frequency and the tube diameter). The time delay was determined by equating the unsteady fluid forces with the quasi-static forces. The results given by this innovative method of measuring the time delay in two-phase flow were consistent with theoretical expectations. The time delay could be expressed as a linear function of the convection time and the time delay parameter was determined for void fractions ranging from 60% to 90%. Fluidelastic instability calculations were also performed using the quasi-steady model with the newly measured time delay parameter. Previously conducted stability tests provided the experimental data necessary to validate the theoretical results of the quasi-steady model. The validity of the quasi-steady model for two-phase flow was confirmed by the good agreement between its results and the experimental data. The newly measured time delay parameter has improved significantly the theoretical results, especially for high void fractions (90%). However, the model could not be verified for void fractions lower or equal to 50% due to the limitation of the current experimental setup. Further studies are consequently required to clarify this point. Nevertheless, this model can be used to simulate the flow induced vibrations in steam generators’ tube bundles as their most critical parts operate at high void fractions (≥ 60%).


Author(s):  
Olufemi E. Bamidele ◽  
Wael H. Ahmed ◽  
Marwan Hassan

Abstract The current work investigates two-phase flow induced vibrations in 90° U-bend. The two-phase induced vibration of the structure was investigated in the vertical, horizontal and axial directions for various flow patterns from bubbly flow to wavy and annular-dispersed flow. The void fractions at various locations along the piping including the fully developed void fraction and the void fraction at the entrance of the U-bend were fully investigated and correlated with the vibration amplitude. The results show that the excitation forces of the two-phase flow in a piping structure are highly dependent on the flow pattern and the flow conditions upstream of the bend. The fully developed void fraction and slip between phases are important in modelling of forces in U-bends and elbows.


Sensors ◽  
2020 ◽  
Vol 20 (7) ◽  
pp. 2088
Author(s):  
Wael Ahmed ◽  
Adib Fatayerji ◽  
Ahmed Elsaftawy ◽  
Marwan Hassan ◽  
David Weaver ◽  
...  

Evaluating the two-phase flow parameters across tube bundles is crucial to the analysis of vibration excitation mechanisms. These parameters include the temporal and local variation of void fraction and phase redistribution. Understanding these two-phase parameters is essential to evaluating the stability threshold of tube bundle configurations. In this work, capacitance sensor probes were designed using finite element analysis to ensure high sensor sensitivity and optimum response. A simulation-based approach was used to calibrate and increase the accuracy of the void fraction measurement. The simulation results were used to scale the normalized capacitance and minimize the sensor uncertainty to ±5%. The sensor and required conditioning circuits were fabricated and tested for measuring the instantaneous void fraction in a horizontal triangular tube bundle array under both static and dynamic two-phase flow conditions. The static calibration of the sensor was able to reduce the uncertainty to ±3% while the sensor conditioning circuit was able to capture instantaneous void fraction signals with frequencies up to 2.5 kHz.


Sign in / Sign up

Export Citation Format

Share Document