Use of a Bubble Tracking Method for Prediction of Downhole Natural Separation Efficiency

2005 ◽  
Vol 127 (4) ◽  
pp. 479-486
Author(s):  
Bin Liu ◽  
Mauricio Prado

For any pumping artificial lift system in the petroleum industry, the free gas significantly affects the performance of the pump and the system above the pump. A model, though not a complete two-phase flow model, has been developed for the effective prediction of separation efficiency across a wide range of production conditions. The model presented is divided into two main parts, the single-phase flow-field solution and the bubble-tracking method. The first part of the model solves the single-phase liquid flow field using the computational fluid dynamics approach. Then, a simple bubble-tracking method was applied to estimate the down-hole natural separation efficiency for two-phase flow. A comparison between the results of the model and the experimental data was conducted. It shows a very good agreement with the experimental data for lower gas void fractions (bubble flow regime).

Author(s):  
Bin Liu ◽  
Mauricio Prado

For any pumping artificial lift system in petroleum industry, the free gas significantly affects the performance of the pump and the system above the pump. A model, though not a complete two-phase flow model, has been developed for the effective prediction of separation efficiency across a wide range of production conditions. The model presented is divided into two main parts, the single-phase flow field solution and the bubble tracking method. The first part of the model solves the single-phase liquid flow field using the CFD approach. Then, a simple bubble-tracking method was applied to estimate the down-hole natural separation efficiency for two-phase flow. A comparison between the results of the model and the experimental data was conducted. It shows a very good agreement with the experimental data for lower gas void fractions (bubble flow regime).


Author(s):  
Christian Weinmu¨ller ◽  
Dimos Poulikakos

Microfluidics has experienced a significant increase in research activities in recent years with a wide range of applications emerging, such as micro heat exchangers, energy conversion devices, microreactors, lab-on-chip devices and micro total chemical analysis systems (μTAS). Efforts to enhance or extend the performance of single phase microfluidic devices are met by two-phase flow systems [1, 2]. Essential for the design and control of microfluidic systems is the understanding of the fluid/hydrodynamic behavior, especially pressure drop correlations. These are well established for single phase flow, however, analytical correlations for two-phase flow only reflect experimentally obtained values within an accuracy of ± 50% [3, 4]. The present study illustrates the effect of two-phase flow regimes on the pressure drop. Experimental measurement data is put into relation of calculated values based on established correlations of Lockhart-Martinelli with Chisholm modifications for macroscopic flows [5, 6] and Mishima-Hibiki modifications for microscale flows [7]. Further, the experimental pressure drop data is superimposed onto two-phase flow maps to identify apparent correlations of pressure drop abnormalities and flow regimes. The experiments were conducted in a square microchannel with a width of 200 μm. Optical access is guaranteed by an anodically bonded glass plate on a MEMS fabricated silicon chip. Superficial velocities range from 0.01 m/s to 1 m/s for the gas flow and from 0.0001 m/s to 1 m/s for the liquid flow with water as liquid feed and CO2 as gas. The analysis of the flow regimes was performed by imaging the distinct flow regimes by laser induced fluorescence microscopy, employing Rhodamine B as the photosensitive dye. The pressure drop was synchronically recorded with a 200 mbar, 2.5 bar and 25 bar differential pressure transmitter and the data was exported via a LabView based software environment, see Figure 1. Figure 2 illustrates the experimentally obtained pressure drop in comparison to the calculated values based on the Lockhard-Martinelli correlation with the Chisholm modification and the Mishima-Hibiki modification. For both cases the predications underestimate the two-phase pressure drop by more than 50%. Nevertheless, the regression of the experimental data has an offset of linear nature. Two-phase flow is assigned to flow regime maps of bubbly, wedging, slug or annular flow defined by superficial gas and liquid velocities. In Figure 3 the pressure drop is plotted as a surface over the corresponding flow regime map. Transition lines indicate a change of flow regimes enclosing an area of an anticline in the pressure data. In the direct comparison between the calculated and the measured values, the two surfaces show a distinct deviation. Especially, the anticline of the experimental data is not explained by the analytical correlations. Figure 4 depicts the findings of Figure 3 at a constant superficial velocity of 0.0232 m/s. The dominant influence of the flow regimes on the pressure drop becomes apparent, especially in the wedging flow regime. The evident deviation of two-phase flow correlations for the pressure drop is based on omitting the influence of the flow regimes. In conclusion, the study reveals a strong divergence of pressure drop measurements in microscale two-phase flow from established correlations of Lockhart-Martinelli and recognized modifications. In reference to [8, 9], an analytical model incorporating the flow regimes and, hence, predicting the precise pressure drop would be of great benefit for hydrodynamic considerations in microfluidics.


1985 ◽  
Vol 107 (1) ◽  
pp. 142-151 ◽  
Author(s):  
J. P. Langlinais ◽  
A. T. Bourgoyne ◽  
W. R. Holden

The calculation of single-phase and two-phase flowing pressure gradients in a well annulus is generally based on an extension of empirical correlations developed for Newtonian fluids in circular pipes. Various techniques for extending pipe flow correlations to an annular geometry have been presented in the literature which involve the representation of the annular well geometry with an equivalent circular diameter and the representation of non-Newtonian fluid behavior with an apparent Newtonian viscosity. Unfortunately, little experimental data have been available which would allow a comparison of the relative accuracy of the various proposed techniques. In this study, experimental pressure gradient data have been taken in two 6000-ft wells. Frictional pressure losses for single-phase flow (mud only) in two annuli were compared to values predicted by the Bingham plastic and power law models. These calculations utilized the equivalent diameters defined by the Crittendon criteria, the hydraulic diameter, and the slot approximation. Also, total pressure difference for two-phase flow was measured for one annular geometry. This data was compared to that predicted by the Poettmann and Carpenter, Hagedorn and Brown, Orkiszewski, and Beggs and Brill correlations. Comparison of experimental data with the various prediction techniques was favorable, each having advantage in certain situations. For the data investigated, the Crittendon criteria using a Bingham plastic model gave the best results. The two-phase flow data was best predicted by the Hagedorn and Brown correlation utilizing an equivalent hydraulic diameter.


2021 ◽  
Author(s):  
Baihui Jiang ◽  
Zhiwei Zhou ◽  
Yu Ji

Abstract With compact structure and enhanced heat transfer capacity, helical-coiled once through steam generators (HTSGs) are widely used in the small modular reactors (SMRs). Nevertheless, the inside centrifugal forces make the flow more complicated, and increase the frictional pressure drop, which is closely related to the dual test of alternating thermal stress and flow instability. Therefore, the analysis of the friction factor in helically coiled tubes is significant to the efficient and safe operation of HTSGs. While the friction factor of single-phase flow in helically coiled tubes was fully studied and extensive correlations have been validated by a large amount of experimental data, the friction factor of two-phase flow still lacks feasible prediction due to its much more complexity. The existed correlations of two-phase flow in helically coiled tubes are mostly based on specified experimental parameters, so the applicable range is limited. Few scholars have tried to extend these correlations to broader applicability, but the trivial applicable range is unsuitable for program development or engineering design, which needs an accurate prediction of friction factor in a wider range. In this paper, existing frictional pressure drop correlations are investigated. The accuracy of single-phase frictional pressure drop correlations is verified through the comparison of calculation results. Since the known experimental data cannot cover a wide range of parameters, two assumptions are proposed, and the rationality is verified through the existing experimental data and calculation analysis. Based on the two assumptions and calculation, a set of calculation correlations for frictional pressure drop of two-phase flow in helically coiled tubes are proposed. The accuracy of this calculation model is validated by experimental data. The scope of application of this model is: D / d = 15–100, P = 0.12–6.3MPa, G = 200–1500kg / m2s, which is sufficient to support the design and operation of steam generators and the development of the simulation programs.


Author(s):  
Veera Manek ◽  
Tao Fang ◽  
S. Mostafa Ghiaasiaan ◽  
Jeff Patelczyk

Abstract Single-phase and two-phase frictional pressure drop in horizontally-oriented double helically coiled tubes confined in a cylindrical shell is experimentally studied using an instrumented test loop that represents a prototypical liquified natural gas (LNG) fuel delivery system for internal combustion (IC) engines. Adiabatic experimental data addressing liquid (water) and gas (nitrogen) single-phase flows, as well as two-phase flows (air-water) in the helicoidally coiled tubes are presented. The range of Reynolds numbers for single-phase flow experiments is 2600 to 4800. In two-phase flow experiments the liquid-only and gas-only Reynolds numbers varied in 1030 to 6600 and 1700 to 17700 ranges, respectively. In laminar single-phase flow regime the measured friction factors are in relatively good agreement with well-established correlations. In the turbulent flow regime the measured friction factors are moderately higher than the prediction of well-established published correlations. Two-phase flow frictional pressure drops are compared with some relevant correlations, with poor agreement. The generated experimental data are empirically correlated based on the two-phase flow multiplier concept.


2004 ◽  
Author(s):  
Gary Luke ◽  
Mark Eagar ◽  
Michael Sears ◽  
Scott Felt ◽  
Bob Prozan

2013 ◽  
Vol 135 (3) ◽  
Author(s):  
Téguewindé Sawadogo ◽  
Njuki Mureithi

Having previously verified the quasi-steady model under two-phase flow laboratory conditions, the present work investigates the feasibility of practical application of the model to a prototypical steam generator (SG) tube subjected to a nonuniform two-phase flow. The SG tube vibration response and normal work-rate induced by tube-support interaction are computed for a range of flow conditions. Similar computations are performed using the Connors model as a reference case. In the quasi-steady model, the fluid forces are expressed in terms of the quasi-static drag and lift force coefficients and their derivatives. These forces have been measured in two-phase flow over a wide range of void fractions making it possible to model the effect of void fraction variation along the tube span. A full steam generator tube subjected to a nonuniform two-phase flow was considered in the simulations. The nonuniform flow distribution corresponds to that along a prototypical steam-generator tube based on thermal-hydraulic computations. Computation results show significant and important differences between the Connors model and the two-phase flow based quasi-steady model. While both models predict the occurrence of fluidelastic instability, the predicted pre-instability and post instability behavior is very different in the two models. The Connors model underestimates the flow-induced negative damping in the pre-instability regime and vastly overestimates it in the post instability velocity range. As a result the Connors model is found to underestimate the work-rate used in the fretting wear assessment at normal operating velocities, rendering the model potentially nonconservative under these practically important conditions. Above the critical velocity, this model largely overestimates the work-rate. The quasi-steady model on the other hand predicts a more moderately increasing work-rate with the flow velocity. The work-rates predicted by the model are found to be within the range of experimental results, giving further confidence to the predictive ability of the model. Finally, the two-phase flow based quasi-steady model shows that fluidelastic forces may reduce the effective tube damping in the pre-instability regime, leading to higher than expected work-rates at prototypical operating velocities.


Sign in / Sign up

Export Citation Format

Share Document