Single-Phase and Two-Phase Flow Pressure Drop in a Long Double Helicoidally-Coiled Tube

Author(s):  
Veera Manek ◽  
Tao Fang ◽  
S. Mostafa Ghiaasiaan ◽  
Jeff Patelczyk

Abstract Single-phase and two-phase frictional pressure drop in horizontally-oriented double helically coiled tubes confined in a cylindrical shell is experimentally studied using an instrumented test loop that represents a prototypical liquified natural gas (LNG) fuel delivery system for internal combustion (IC) engines. Adiabatic experimental data addressing liquid (water) and gas (nitrogen) single-phase flows, as well as two-phase flows (air-water) in the helicoidally coiled tubes are presented. The range of Reynolds numbers for single-phase flow experiments is 2600 to 4800. In two-phase flow experiments the liquid-only and gas-only Reynolds numbers varied in 1030 to 6600 and 1700 to 17700 ranges, respectively. In laminar single-phase flow regime the measured friction factors are in relatively good agreement with well-established correlations. In the turbulent flow regime the measured friction factors are moderately higher than the prediction of well-established published correlations. Two-phase flow frictional pressure drops are compared with some relevant correlations, with poor agreement. The generated experimental data are empirically correlated based on the two-phase flow multiplier concept.

Author(s):  
Ashish Kotwal ◽  
Che-Hao Yang ◽  
Clement Tang

The current study shows computational and experimental analysis of multiphase flows (gas-liquid two-phase flow) in channels with sudden area change. Four test sections used for sudden contraction and expansion of area in experiments and computational analysis. These are 0.5–0.375, 0.5–0.315, 0.5–0.19, 0.5–0.14, inversely true for expansion channels. Liquid Flow rates ranging from 0.005 kg/s to 0.03 kg/s employed, while gas flow rates ranging from 0.00049 kg/s to 0.029 kg/s implemented. First, single-phase flow consists of only water, and second two-phase Nitrogen-Water mixture flow analyzed experimentally and computationally. For Single-phase flow, two mathematical models used for comparison: the two transport equations k-epsilon turbulence model (K-Epsilon), and the five transport equations Reynolds stress turbulence interaction model (RSM). A Eulerian-Eulerian multiphase approach and the RSM mathematical model developed for two-phase gas-liquid flows based on current experimental data. As area changes, the pressure drop observed, which is directly proportional to the Reynolds number. The computational analysis can show precise prediction and a good agreement with experimental data when area ratio and pressure differences are smaller for laminar and turbulent flows in circular geometries. During two-phase flows, the pressure drop generated shows reasonable dependence on void fraction parameter, regardless of numerical analysis and experimental analysis.


Author(s):  
Christian Weinmu¨ller ◽  
Dimos Poulikakos

Microfluidics has experienced a significant increase in research activities in recent years with a wide range of applications emerging, such as micro heat exchangers, energy conversion devices, microreactors, lab-on-chip devices and micro total chemical analysis systems (μTAS). Efforts to enhance or extend the performance of single phase microfluidic devices are met by two-phase flow systems [1, 2]. Essential for the design and control of microfluidic systems is the understanding of the fluid/hydrodynamic behavior, especially pressure drop correlations. These are well established for single phase flow, however, analytical correlations for two-phase flow only reflect experimentally obtained values within an accuracy of ± 50% [3, 4]. The present study illustrates the effect of two-phase flow regimes on the pressure drop. Experimental measurement data is put into relation of calculated values based on established correlations of Lockhart-Martinelli with Chisholm modifications for macroscopic flows [5, 6] and Mishima-Hibiki modifications for microscale flows [7]. Further, the experimental pressure drop data is superimposed onto two-phase flow maps to identify apparent correlations of pressure drop abnormalities and flow regimes. The experiments were conducted in a square microchannel with a width of 200 μm. Optical access is guaranteed by an anodically bonded glass plate on a MEMS fabricated silicon chip. Superficial velocities range from 0.01 m/s to 1 m/s for the gas flow and from 0.0001 m/s to 1 m/s for the liquid flow with water as liquid feed and CO2 as gas. The analysis of the flow regimes was performed by imaging the distinct flow regimes by laser induced fluorescence microscopy, employing Rhodamine B as the photosensitive dye. The pressure drop was synchronically recorded with a 200 mbar, 2.5 bar and 25 bar differential pressure transmitter and the data was exported via a LabView based software environment, see Figure 1. Figure 2 illustrates the experimentally obtained pressure drop in comparison to the calculated values based on the Lockhard-Martinelli correlation with the Chisholm modification and the Mishima-Hibiki modification. For both cases the predications underestimate the two-phase pressure drop by more than 50%. Nevertheless, the regression of the experimental data has an offset of linear nature. Two-phase flow is assigned to flow regime maps of bubbly, wedging, slug or annular flow defined by superficial gas and liquid velocities. In Figure 3 the pressure drop is plotted as a surface over the corresponding flow regime map. Transition lines indicate a change of flow regimes enclosing an area of an anticline in the pressure data. In the direct comparison between the calculated and the measured values, the two surfaces show a distinct deviation. Especially, the anticline of the experimental data is not explained by the analytical correlations. Figure 4 depicts the findings of Figure 3 at a constant superficial velocity of 0.0232 m/s. The dominant influence of the flow regimes on the pressure drop becomes apparent, especially in the wedging flow regime. The evident deviation of two-phase flow correlations for the pressure drop is based on omitting the influence of the flow regimes. In conclusion, the study reveals a strong divergence of pressure drop measurements in microscale two-phase flow from established correlations of Lockhart-Martinelli and recognized modifications. In reference to [8, 9], an analytical model incorporating the flow regimes and, hence, predicting the precise pressure drop would be of great benefit for hydrodynamic considerations in microfluidics.


2021 ◽  
Author(s):  
Baihui Jiang ◽  
Zhiwei Zhou ◽  
Yu Ji

Abstract With compact structure and enhanced heat transfer capacity, helical-coiled once through steam generators (HTSGs) are widely used in the small modular reactors (SMRs). Nevertheless, the inside centrifugal forces make the flow more complicated, and increase the frictional pressure drop, which is closely related to the dual test of alternating thermal stress and flow instability. Therefore, the analysis of the friction factor in helically coiled tubes is significant to the efficient and safe operation of HTSGs. While the friction factor of single-phase flow in helically coiled tubes was fully studied and extensive correlations have been validated by a large amount of experimental data, the friction factor of two-phase flow still lacks feasible prediction due to its much more complexity. The existed correlations of two-phase flow in helically coiled tubes are mostly based on specified experimental parameters, so the applicable range is limited. Few scholars have tried to extend these correlations to broader applicability, but the trivial applicable range is unsuitable for program development or engineering design, which needs an accurate prediction of friction factor in a wider range. In this paper, existing frictional pressure drop correlations are investigated. The accuracy of single-phase frictional pressure drop correlations is verified through the comparison of calculation results. Since the known experimental data cannot cover a wide range of parameters, two assumptions are proposed, and the rationality is verified through the existing experimental data and calculation analysis. Based on the two assumptions and calculation, a set of calculation correlations for frictional pressure drop of two-phase flow in helically coiled tubes are proposed. The accuracy of this calculation model is validated by experimental data. The scope of application of this model is: D / d = 15–100, P = 0.12–6.3MPa, G = 200–1500kg / m2s, which is sufficient to support the design and operation of steam generators and the development of the simulation programs.


2021 ◽  
Author(s):  
Gang Yang ◽  
Kai Feng ◽  
Jia-Pei Li ◽  
Yu-Hang Gao ◽  
Hui-Chen Zhang

Abstract Pressure drop and bubble morphology are essential characteristics of microfluidic system design and process control. In this paper, a new type of microfluidic chip was designed and produced, including a flow-focusing device and a fluid transport device to simulate bubble generation and fluid transport in practical applications. Nitrogen and sodium carboxymethyl cellulose solutions of different concentrations were used as the gas and liquid phases. Single-phase flow and two-phase flow experiments were designed according to the commonly used flow conditions in the microchannel. By changing the flow rates of liquid and gas, the pressure drop in the fluid transport device of the two fluid states, the length of the bubble generated in the flow-focusing device, and the length of the bubble after passing through the transport device were measured, respectively. The influence of non-Newtonian characteristics of the liquid on pressure drop and the length of the generated bubbles were analyzed. The results show that the non-Newtonian characteristics of fluid have a significant effect on the pressure drop of single-phase flow and two-phase flow. Within a specific flow velocity range, the bubble length can be predicted according to the dimensionless number of the liquid. The pressure drop increases the bubble length to varying degrees.


Author(s):  
Suizheng Qiu ◽  
Minoru Takahashi ◽  
Guanghui Su ◽  
Dounan Jia

Water single-phase and nucleate boiling heat transfer were experimentally investigated in vertical annuli with narrow gaps. The experimental data about water single-phase flow and boiling two-phase flow heat transfer in narrow annular channel were accumulated by two test sections with the narrow gaps of 1.0mm and 1.5mm. Empirical correlations to predict the heat transfer of the single-phase flow and boiling two-phase flow in the narrow annular channel were obtained, which were arranged in the forms of the Dittus-Boelter for heat transfer coefficients in a single-phase flow and the Jens-Lottes formula for a boiling two-phase flow in normal tubes, respectively. The mechanism of the difference between the normal channel and narrow annular channel were also explored. From experimental results, it was found that the turbulent heat transfer coefficients in narrow gaps are nearly the same to the normal channel in the experimental range, and the transition Reynolds number from a laminar flow to a turbulent flow in narrow annuli was much lower than that in normal channel, whereas the boiling heat transfer in narrow annular gap was greatly enhanced compared with the normal channel.


Author(s):  
Toshimichi Arai ◽  
Naoki Kudo ◽  
Tsuneaki Ishima ◽  
Ismail M. Youssef ◽  
Tomio Obokata ◽  
...  

Characteristics on particle motion in a liquid-solid two-phase jet flow were studied in the paper. The water jet including glass particle of 389 μm in mean diameter was injected into water bath. The experimental conditions were 0.21% of initial particle volume ratio, 5mm in pipe diameter and 1.84 m/s of mean velocity on outlet of the jet. A laser Doppler anemometer (LDA) with size discrimination was applied for measuring the time serious velocities of the single-phase flow, particle and water phase flow. A particle image velocimetry (PIV) was also applied in the two-phase flow. The normal PIV method can hardly measure the particle size and perform the particle size discrimination. In the experiment, using the gray scales related with the scattering light intensity, measuring method with size discrimination in two-phase flow was carried out. The experimental results show less difference between velocities of single-phase flow and water-phase flow under this low particle volume ratio condition. Particles have the relative motion with the water-phase and large rms velocity. The PIV used in this experiment, which is called multi-intensity-layer-PIV: MILP, can measure water-phase velocity with good accuracy.


1985 ◽  
Vol 107 (1) ◽  
pp. 142-151 ◽  
Author(s):  
J. P. Langlinais ◽  
A. T. Bourgoyne ◽  
W. R. Holden

The calculation of single-phase and two-phase flowing pressure gradients in a well annulus is generally based on an extension of empirical correlations developed for Newtonian fluids in circular pipes. Various techniques for extending pipe flow correlations to an annular geometry have been presented in the literature which involve the representation of the annular well geometry with an equivalent circular diameter and the representation of non-Newtonian fluid behavior with an apparent Newtonian viscosity. Unfortunately, little experimental data have been available which would allow a comparison of the relative accuracy of the various proposed techniques. In this study, experimental pressure gradient data have been taken in two 6000-ft wells. Frictional pressure losses for single-phase flow (mud only) in two annuli were compared to values predicted by the Bingham plastic and power law models. These calculations utilized the equivalent diameters defined by the Crittendon criteria, the hydraulic diameter, and the slot approximation. Also, total pressure difference for two-phase flow was measured for one annular geometry. This data was compared to that predicted by the Poettmann and Carpenter, Hagedorn and Brown, Orkiszewski, and Beggs and Brill correlations. Comparison of experimental data with the various prediction techniques was favorable, each having advantage in certain situations. For the data investigated, the Crittendon criteria using a Bingham plastic model gave the best results. The two-phase flow data was best predicted by the Hagedorn and Brown correlation utilizing an equivalent hydraulic diameter.


Sign in / Sign up

Export Citation Format

Share Document