scholarly journals Investigation of the Three-Dimensional Flow Field Within a Transonic Fan Rotor: Experiment and Analysis

1985 ◽  
Vol 107 (2) ◽  
pp. 436-448 ◽  
Author(s):  
M. J. Pierzga ◽  
J. R. Wood

An experimental investigation of the three-dimensional flow field through a low aspect ratio, transonic, axial-flow fan rotor has been conducted using an advanced laser anemometer (LA) system. Laser velocimeter measurements of the rotor flow field at the design operating speed and over a range of through flow conditions are compared to analytical solutions. The numerical technique used herein yields the solution to the full, three-dimensional, unsteady Euler equations using an explicit time-marching, finite volume approach. The numerical analysis, when coupled with a simplified boundary layer calculation, generally yields good agreement with the experimental data. The test rotor has an aspect ratio of 1.56, a design total pressure ratio of 1.629 and a tip relative Mach number of 1.38. The high spatial resolution of the LA data matrix (9 radial × 30 axial × 50 blade-to-blade) permits details of the transonic flow field such as shock location, turning distribution, and blade loading levels to be investigated an compared to analytical results.

Author(s):  
Zhaohui Du ◽  
Wanlai Lin ◽  
Xiaocheng Zhu ◽  
Yan Zhao

In this paper, a three-color dual-beam PDA (Particle Dynamic Analyzer) system (made by DANTEC Measurement Technology) is used to measure the three-dimensional velocity of an axial flow fan. Due to the geometrical limit of fan rotor, non-orthogonal velocity components are measured first, from which the orthogonal three-dimensional components of the velocity field are computed through transformation equations. The detailed flow fields at 15 axial locations upstream, inside and at the exit of the rotor are measured, respectively. On each cross section perpendicular to the rotating axis, the flow field measurement at 15 different radial locations from 50% of the blade span to the region inside the tip clearance (between the tip blade and the casing wall) are taken. The experimental technique is described, and the three dimensional flow fields (including the tip clearance flow) are presented and analyzed.


2017 ◽  
Author(s):  
Adnan Ismael ◽  
Hamid Hussein ◽  
Mohammed Tareq ◽  
Mustafa Gunal

e-Polymers ◽  
2020 ◽  
Vol 20 (1) ◽  
pp. 724-732
Author(s):  
Changchun Ji ◽  
Yudong Wang

AbstractTo investigate the distribution characteristics of the three-dimensional flow field under the slot die, an online measurement of the airflow velocity was performed using a hot wire anemometer. The experimental results show that the air-slot end faces have a great influence on the airflow distribution in its vicinity. Compared with the air velocity in the center area, the velocity below the slot end face is much lower. The distribution characteristics of the three-dimensional flow field under the slot die would cause the fibers at different positions to bear inconsistent air force. The air velocity of the spinning centerline is higher than that around it, which is more conducive to fiber diameter attenuation. The violent fluctuation of the instantaneous velocity of the airflow could easily cause the meltblowing fiber to whip in the area close to the die.