Lower Plenum Voiding

1982 ◽  
Vol 104 (3) ◽  
pp. 479-486 ◽  
Author(s):  
D. Bharathan ◽  
G. B. Wallis ◽  
H. J. Richter

One of the phenomena involved in a loss-of-coolant accident in a pressurized water reactor may be lower plenum voiding. This might occur during the blowdown phase after a cold-leg break in the primary coolant circuit. Steam generated in the reactor core may flow out of the bottom of the reactor core, turn in the lower plenum of the vessel, in a direction countercurrent to the emergency core coolant flow, and escape via the break. If its velocity is high enough, this steam may sweep water from the bottom (lower plenum) of the reactor vessel. Emergency coolant added to the vessel may also be carried out by the escaping steam and thus the reflooding of the core would be delayed. This paper describes a study of two-phase hydrodynamics associated with lower plenum voiding. Several geometrical configurations were tested at three different scales, using air to simulate the steam. Comparisons were made with data obtained by other researchers.

Author(s):  
Salwa Helmy ◽  
Magy Kandil ◽  
Ahmed Refaey

In Nuclear Power Plants the Design Extension Conditions are more complex and severe than those postulated as Design Basis Accidents, therefore, they must be taken into account in the safety analyses. In this study, many hypothetical investigated transients are applied on KONVOI pressurized water reactor during a 6-in. (182 cm2) cold leg Small Break Loss-of-Coolant-Accident to revise the effects of all safety systems ways through their availability/ nonavailability on the thermal hydraulic behaviour of the reactor. The investigated transients are represented through three cases of Small Break Loss-of-Coolant-Accident as, case-1, without scram and all of the safety systems are failure, case-2, the normal scram actuation with failure of all safety systems (nonavailability), and finally case 3, with normal actuation scram sequence and normal sequential actuation of all safety systems (availability). These three investigated transient cases are simulated by creation a model using Analysis of Thermal-Hydraulics of LEaks and Transient code. In all transient cases, all types of reactivity feedbacks, boron, moderator density, moderator temperature and fuel temperature are considered. The steady-state results are nearly in agreement with the plant parameters available in previous literatures. The results show the importance effects of the feedbacks reactivity at Loss-of-Coolant-Accident on the fallouts power, since they are considered the key parameters for controlling the clad and fuel temperatures to maintain them below their melting point. Moreover, the calculated results in all cases show that the thermal hydraulic parameters are in acceptable ranges and encounter the safety criterion during Loss-of-Coolant-Accident the Design Extension Conditions accidents processes. Furthermore, the results show that the core uncovers and fuel heat up do not occur in KONVOI pressurized water reactor in theses the Design Extension Conditions simulations since, all safety systems provide adequate core cooling by sufficient water inventory into the core to cover it.


Author(s):  
Yaroslav Dubyk ◽  
Vladislav Filonov ◽  
Oleksii Ishchenko ◽  
Igor Orynyak ◽  
Yuliia Filonova

This article focuses on the dynamic behavior of the Pressurized Water Reactor (PWR) during the Loss Of Coolant Accident (LOCA) which cause the significant acoustic loads on the Core Shrouds. The finite element analysis of a PWR was performed to obtain the acoustic response to the LOCA event. We have performed dynamic stress and strain calculations in the frequency domain for the Core Barrel, according to classical shell theories. The Duhamel integral was used to calculate the transient response of a shell to the transient load caused by the water hammer event. The results obtained were used for fracture mechanics evaluations for flaws, which may occur between inservice inspections.


Author(s):  
Soo W. Jo ◽  
Yong K. Lee ◽  
Jong C. Jo

Temperature of pressurized water reactor (PWR) core is a key parameter used widely for judging the initiation of emergency operating procedures and severe accident management. Since direct measurement of the fuel cladding surface temperature using thermocouples is not practicable currently, the coolant temperature at the core exit locations is monitored instead. Several experimental researches showed that the CET rise during a loss of coolant accident (LOCA) and its magnitudes were always lower than the actual fuel rod cladding temperature at the same time. In this regard, a theoretical analysis of the transient heat transfer of coolant flow in a PWR core is needed to confirm the findings from the previous experimental works. This paper addresses numerical simulation of the transient boiling-induced multiphase flow through a simplified PWR core model during a LOCA by a commercial computational fluid dynamics (CFD) code. The calculated results are discussed to understand the transient heat transfer mechanism in the core and to provide useful technical information for reactor design and operation.


2021 ◽  
Vol 134 ◽  
pp. 103648
Author(s):  
Katarzyna Skolik ◽  
Chris Allison ◽  
Judith Hohorst ◽  
Mateusz Malicki ◽  
Marina Perez-Ferragut ◽  
...  

2018 ◽  
Vol 4 (2) ◽  
pp. 149-154
Author(s):  
Aleksey Kulikov ◽  
Andrey Lepyokhin ◽  
Vitaly Polunichev

The purpose of the work was to optimize the parameters of the spillage system equipped with a gas pressure hydroaccumulator for a ship pressurized water reactor in a loss-of-coolant accident. The water-gas ratio in the hydroaccumulator and the hydraulic resistance of the path between the hydroaccumulator and the reactor were optimized at the designed hydroaccumulator geometric volume. The main dynamic processes were described using a mathematical model and a computational analysis. A series of numerical calculations were realized to simulate the behavior dynamics of the coolant level in the reactor during the accident – by varying the optimized parameters. Estimates of the minimum and maximum values of the coolant level were obtained: depending on the initial water-gas ratio in the hydroaccumulator at different diameters of the flow restrictor on the path between the hydroaccumulator and the reactor. These results were obtained subject to the restrictive conditions that, during spillage, the coolant level should remain above the core and below the blowdown nozzle. The first condition implies that the core is in safe state, the second excludes the coolant water blowdown. The optimization goal was to achieve the maximum time interval in which these conditions would be satisfied simultaneously. The authors propose methods for selecting the optimal spillage system parameters; these methods provide the maximum time for the core to be in a safe state during a loss-of-coolant accident at the designed hydroaccumulator volume. Using these methods, it is also possible to make assessments from the early stages of designing reactor plants.


2020 ◽  
Vol 01 (02) ◽  
pp. 53-60
Author(s):  
Pronob Deb Nath ◽  
Kazi Mostafijur Rahman ◽  
Md. Abdullah Al Bari

This paper evaluates the thermal hydraulic behavior of a pressurized water reactor (PWR) when subjected to the event of Loss of Coolant Accident (LOCA) in any channel surrounding the core. The accidental break in a nuclear reactor may occur to circulation pipe in the main coolant system in a form of small fracture or equivalent double-ended rupture of largest pipe connected to primary circuit line resulting potential threat to other systems, causing pressure difference between internal parts, unwanted core shut down, explosion and radioactivity release into environment. In this computational study, LOCA for generation III+ VVER-1200 reactor has been carried out for arbitrary break at cold leg section with and without Emergency Core Cooling System (ECCS). PCTRAN, a thermal hydraulic model-based software developed using real data and computational approach incorporating reactor physics and control system was employed in this study. The software enables to test the consequences related to reactor core operations by monitoring different operating variables in the system control bar. Two types of analysis were performed -500% area break at cold leg pipe due to small break LOCA caused by malfunction of the system with and without availability of ECCS. Thermal hydraulic parameters like, coolant dynamics, heat transfer, reactor pressure, critical heat flux, temperature distribution in different sections of reactor core have also been investigated in the simulation. The flow in the reactor cooling system, steam generators steam with feed-water flow, coolant steam flow through leak level of water in different section, power distribution in core and turbine were plotted to analyze their behavior during the operations. The simulation showed that, LOCA with unavailability of Emergency Core Cooling System (ECCS) resulted in core meltdown and release of radioactivity after a specific time.


Sign in / Sign up

Export Citation Format

Share Document