Heat Transfer During Near-Critical-Pressure Condensation of Refrigerant Blends

2016 ◽  
Vol 138 (5) ◽  
Author(s):  
Srinivas Garimella ◽  
Ulf C. Andresen ◽  
Biswajit Mitra ◽  
Yirong Jiang ◽  
Brian M. Fronk

Heat transfer during condensation of refrigerant blends R404A and R410A flowing through horizontal tubes with 0.76 ≤ D ≤ 9.4 mm at nominal Pr = 0.8–0.9 was investigated. Local heat transfer coefficients were measured for the mass flux range 200 < G < 800 kg m−2 s−1 in small quality increments over the entire vapor–liquid region. Heat transfer coefficients increased with quality and mass flux, while the effect of reduced pressure was not very significant within this range of pressures. The heat transfer coefficients increased with a decrease in diameter. Correlations from the literature were not able to predict the condensation heat transfer coefficient for these fluids at these near-critical pressures over the wide range of tube diameters under consideration. A new flow-regime based model for heat transfer in the wavy, annular, and annular/wavy transition regimes, which predicts 91% of the data within ±25%, is proposed.

2006 ◽  
Vol 129 (8) ◽  
pp. 958-965 ◽  
Author(s):  
Yirong Jiang ◽  
Biswajit Mitra ◽  
Srinivas Garimella ◽  
Ulf C. Andresen

This paper presents the results of an experimental study on condensation heat transfer of refrigerant blends R404A and R410A flowing through horizontal tubes of 9.4 and 6.2mm inner diameter at nominal pressures of 80% and 90% of the critical pressure. Local heat transfer coefficients were measured for the mass flux range 200<G<800kg∕m2‐s in small quality increments over the entire vapor-liquid region. Heat transfer coefficients increased with quality and mass flux, while the effect of reduced pressure was not very significant within this range of pressures. The heat transfer coefficients increased with a decrease in diameter.


2015 ◽  
Vol 19 (5) ◽  
pp. 1769-1789 ◽  
Author(s):  
Volodymyr Rifert ◽  
Volodymyr Sereda

Survey of the works on condensation inside smooth horizontal tubes published from 1955 to 2013 has been performed. Theoretical and experimental investigations, as well as more than 25 methods and correlations for heat transfer prediction are considered. It is shown that accuracy of this prediction depends on the accuracy of volumetric vapor content and pressure drop at the interphase. The necessity of new studies concerning both local heat transfer coefficients and film condensation along tube perimeter and length under annular, stratified and intermediate regimes of phase flow was substantiated. These characteristics being defined will allow determining more precisely the boundaries of the flow regimes and the methods of heat transfer prediction.


1980 ◽  
Vol 102 (3) ◽  
pp. 471-476 ◽  
Author(s):  
G. Breber ◽  
J. W. Palen ◽  
J. Taborek

In order to select the appropriate correlations for prediction of horizontal tubeside condensation heat transfer coefficients, it is necessary to estimate what types of flow patterns exist at various points along the tube. The main criteria required are shown to be the ratio of shear to gravity forces on the condensate film and the ratio of vapor volume to liquid volume. A recently proposed prediction method by Taitel and Dukler is compared with observed flow regimes for condensation in horizontal tubes. The theoretically obtained parameters are shown to characterize the flow regimes well. Based on these parameters, a simplified procedure for prediction of local heat transfer coefficients for pure component condensation in horizontal tubes is proposed.


1999 ◽  
Vol 123 (4) ◽  
pp. 749-757 ◽  
Author(s):  
S. Baldauf ◽  
A. Schulz ◽  
S. Wittig

Local heat transfer coefficients on a flat plate surface downstream a row of cylindrical ejection holes were investigated. The parameters blowing angle, hole pitch, blowing rate, and density ratio were varied over a wide range, emphasizing engine relevant conditions. A high-resolution IR-thermography technique was used for measuring surface temperature fields. Local heat transfer coefficients were obtained from a Finite Element analysis. IR-determined surface temperatures and backside temperatures of the cooled test plate measured with thermocouples were applied as boundary conditions in this heat flux computation. The superposition approach was employed to obtain the heat transfer coefficient hf based on the difference between actual wall temperatures and adiabatic wall temperatures in the presence of film cooling. The hf data are given for an engine relevant density ratio of 1.8. Therefore, heat transfer results with different wall temperature conditions and adiabatic film cooling effectiveness results for identical flow situations (i.e., constant density ratios) were combined. Characteristic surface patterns of the locally resolved heat transfer coefficients hf are recognized and quantified as the different ejection parameters are changed. The detailed results are used to discuss the specific local heat transfer behavior in the presence of film cooling. They also provide a base of surface data essential for the validation of the heat transfer capabilities of CFD codes in discrete hole film cooling.


Author(s):  
C. Aprea ◽  
A. Greco ◽  
G. P. Vanoli

R22 is the most widely employed HCFC working fluid in vapour compression plant. HCFCs must be replaced within 2020. Major problems arise with the substitution of the working fluids, related to the decrease in performance of the plant. Therefore, extremely accurate design procedures are needed. The relative sizing of each of the components of the plant is crucial for cycle performance. For this reason, the knowledge of the new fluids heat transfer characteristics in condensers and evaporators is required. The local heat transfer coefficients and pressure drop of pure R22 and of the azeotropic mixture R507 (R125-R143a 50%/50% in weight) have been measured during convective boiling. The test section is a smooth horizontal tube made of a with a 6 mm I.D. stainless steel tube, 6 m length, uniformly heated by Joule effect. The effects of heat flux, mass flux and evaporation pressure on the heat transfer coefficients are investigated. The evaporating pressure varies within the range 3 ÷10 bar, the refrigerant mass flux within the range 200 ÷ 1000 kg/m2s, the heat flux within 0 ÷ 44 kW/m2. A comparison have been carried out between the experimental data and those predicted by means of the most credited literature relationships.


1980 ◽  
Vol 102 (1) ◽  
pp. 152-157 ◽  
Author(s):  
R. Chandran ◽  
J. C. Chen ◽  
F. W. Staub

The local characteristics of heat transfer from horizontal tubes immersed in fluidized beds were investigated experimentally. Steady-state heat transfer measurements were obtained in air-fluidized beds of glass beads, both for a single tube and a ten-row bare tube bundle. The test results indicated that local heat transfer coefficients are strongly influenced by angular position and gas flow rate, as well as by particle size and system pressure. The heat transfer coefficients, averaged around the circumference of the tube, exhibited a general tendency to increase with decreasing particle size and increasing system pressure. The heat transfer coefficients for a tube in an inner-row position within the bundle were found to be slightly higher than those for a tube in the bottom-row. Comparison of the average heat transfer coefficient data obtained in this study with some of the existing correlations for heat transfer from horizontal tubes showed that the correlations are unsatisfactory.


2008 ◽  
Vol 130 (6) ◽  
Author(s):  
A. Rabah ◽  
S. Kabelac

Local heat transfer coefficients for flow boiling of pure 1,1,1,2-tetrafluoroethane (R134a) and binary mixtures of propane (R290) and R134a were measured. The experimental setup employed a vapor heated plain horizontal tube (di=10mm, do=12mm, L=500mm). The measurements covered a wide range of saturation temperatures (233≤Ts≤278K), mass fluxes (100≤ṁ≤300kg∕m2s), qualities (0≤ẋ≤1), and concentrations (0≤z̃≤0.65). In the zeotropic region of R134a/R290 mixtures, the measured local heat transfer coefficient was found to show a maximum decrease by a factor of 2 relative to that for pure R134a. At the azeotropic point (65% R290), it was found to increase by a factor of 1.2. The measured local heat transfer coefficients for both R134a and R134a/R290 were compared with a number of correlations.


2000 ◽  
Vol 124 (1) ◽  
pp. 133-139 ◽  
Author(s):  
K. Willenborg ◽  
V. Schramm ◽  
S. Kim ◽  
S. Wittig

The influence of a honeycomb facing on the heat transfer of a stepped labyrinth seal with geometry typical for modern jet engines was investigated. Heat transfer measurements were obtained for both a smooth stator and a stator lined with a honeycomb structure. In addition, an LDV system was used with the scaled up geometry to obtain a high local resolution of the velocity distribution in the seal. The experiments covered a wide range of pressure ratios and gap widths, typical for engine operating conditions. Local heat transfer coefficients were calculated from the measured wall and gas temperatures using a finite element code. By averaging the local values, mean heat transfer coefficients were determined and correlations for the global Nusselt numbers were derived for the stator and the rotor. The LDV results showed strong geometrical effects of the honeycomb structure on the development of the flow fields for the honeycomb seal. The distribution of the local heat transfer coefficients are compatible with the flow features identified by the LDV results and reveal a significantly reduced heat transfer with the honeycomb facing compared to the smooth facing.


Author(s):  
S. Baldauf ◽  
A. Schulz ◽  
S. Wittig

Local heat transfer coefficients on a flat plate surface downstream a row of cylindrical ejection holes were investigated. The parameters blowing angle, hole pitch, blowing rate, and density ratio were varied in a wide range emphasizing on engine relevant conditions. A high resolution IR-thermography technique was used for measuring surface temperature fields. Local heat transfer coefficients were obtained by a Finite Element analysis. IR-determined surface temperatures and backside temperatures of the cooled testplate measured with thermocouples were applied as boundary conditions in a heat flux computation. The superposition approach was employed to obtain the heat transfer coefficient hr referring to adiabatic wall temperatures in the presence of film cooling. Therefore, heat transfer results with different wall temperature conditions and adiabatic film cooling effectiveness results of identical flow situations (constant density ratios) were combined. Characteristic surface patterns of the locally resolved heat transfer coefficients hf depending on the various parameters were recognized and quantified. The detailed results are used to discuss the specific local heat transfer behavior in the presence of film cooling. They also provide a base of surface data essential for the validation of the heat transfer capabilities of CFD-codes in discrete hole film cooling.