Local Heat Transfer Coefficients and Pressure Drop During Evaporation in a Smooth Horizontal Tube

Author(s):  
C. Aprea ◽  
A. Greco ◽  
G. P. Vanoli

R22 is the most widely employed HCFC working fluid in vapour compression plant. HCFCs must be replaced within 2020. Major problems arise with the substitution of the working fluids, related to the decrease in performance of the plant. Therefore, extremely accurate design procedures are needed. The relative sizing of each of the components of the plant is crucial for cycle performance. For this reason, the knowledge of the new fluids heat transfer characteristics in condensers and evaporators is required. The local heat transfer coefficients and pressure drop of pure R22 and of the azeotropic mixture R507 (R125-R143a 50%/50% in weight) have been measured during convective boiling. The test section is a smooth horizontal tube made of a with a 6 mm I.D. stainless steel tube, 6 m length, uniformly heated by Joule effect. The effects of heat flux, mass flux and evaporation pressure on the heat transfer coefficients are investigated. The evaporating pressure varies within the range 3 ÷10 bar, the refrigerant mass flux within the range 200 ÷ 1000 kg/m2s, the heat flux within 0 ÷ 44 kW/m2. A comparison have been carried out between the experimental data and those predicted by means of the most credited literature relationships.

2017 ◽  
Vol 25 (02) ◽  
pp. 1750013 ◽  
Author(s):  
Pham-Quang Vu ◽  
Kwang-Il Choi ◽  
Jong-Taek Oh ◽  
Honggi Cho

The condensation heat transfer coefficients and pressure drops of R410A and R22 flowing inside a horizontal aluminum multiport mini-channel tube having 18 channels are investigated. Experimental data are presented for the range of vapor quality from 0.1 to 0.9, mass flux from 50 to 500[Formula: see text]kg/m2s, heat flux from 3 to 15[Formula: see text]kW/m2 and the saturation temperature at 48[Formula: see text]C. The pressure drop across the test section was directly measured by a differential pressure transducer. At a small scale, the noncircular cross-sections can enhance the effect of the surface tension. The average heat transfer coefficient increased with the increase of vapor quality, mass flux and heat flux. Under the same test conditions, the heat transfer coefficients of R22 are higher than those for R410A, the pressure drops for R410A are 7–19% lower than those of R22. The lower pressure drop of R410A has an important advantage as an alternative working fluid for R22 in air-conditioning and heat pump systems.


Author(s):  
Lindsey V. Randle ◽  
Brian M. Fronk

Abstract In this study, we use infrared thermography to calculate local heat transfer coefficients of top and bottom heated flows of near-critical carbon dioxide in an array of parallel microchannels. These data are used to evaluate the relative importance of buoyancy for different flow arrangements. A Joule heated thin wall made of Inconel 718 applies a uniform heat flux either above or below the horizontal flow. A Torlon PAI test section consists of three parallel microchannels with a hydraulic diameter of 923 μm. The reduced inlet temperature (TR = 1.006) and reduced pressure (PR = 1.03) are held constant. For each heater orientation, the mass flux (520 kgm−2s−2 ≤ G ≤ 800 kgm−2s−2) and heat flux (4.7 Wcm−2 ≤ q″ ≤ 11.1 Wcm−2) are varied. A 2D resistance network analysis method calculates the bulk temperatures and heat transfer coefficients. In this analysis, we divide the test section into approximately 250 segments along the stream-wise direction. We then calculate the bulk temperatures using the enthalpy from the upstream segment, the heat flux in a segment, and the pressure. To isolate the effect of buoyancy, we screen the data to omit conditions where flow acceleration may be important or where relaminarization may occur. In the developed region of the channel, there was a 10 to 15 percent reduction of the local heat transfer coefficients for the upward heating mode compared to downward heating with the same mass and heat fluxes. Thus buoyancy effects should be considered when developing correlations for these types of flow.


1999 ◽  
Vol 122 (2) ◽  
pp. 387-391 ◽  
Author(s):  
S.-S. Hsieh ◽  
K.-J. Jang ◽  
Y.-C. Tsai

Results of a study on saturated boiling heat transfer of refrigerant R-600a in horizontal tubes (ID=10.6 mm) with strip-type inserts (longitudinal strip LS with/without perforated holes and cross-strip CS inserts) are reported. Local heat transfer coefficients are measured for a range of heat flux (9.1∼31.2 kW/m2), mass velocity (8.23∼603.3 kg/m2s), and equilibrium mass quality (⩽0.8) and the influences were studied. The data were compared with the performance of the corresponding smooth tubes. Enhancement factors are presented and discussed. Pressure drop measurement was also conducted and it is found that both single-phase and two-phase pressure drops increase with increasing heat flux levels and mass velocities. [S0022-1481(00)00302-9]


2008 ◽  
Vol 130 (6) ◽  
Author(s):  
A. Rabah ◽  
S. Kabelac

Local heat transfer coefficients for flow boiling of pure 1,1,1,2-tetrafluoroethane (R134a) and binary mixtures of propane (R290) and R134a were measured. The experimental setup employed a vapor heated plain horizontal tube (di=10mm, do=12mm, L=500mm). The measurements covered a wide range of saturation temperatures (233≤Ts≤278K), mass fluxes (100≤ṁ≤300kg∕m2s), qualities (0≤ẋ≤1), and concentrations (0≤z̃≤0.65). In the zeotropic region of R134a/R290 mixtures, the measured local heat transfer coefficient was found to show a maximum decrease by a factor of 2 relative to that for pure R134a. At the azeotropic point (65% R290), it was found to increase by a factor of 1.2. The measured local heat transfer coefficients for both R134a and R134a/R290 were compared with a number of correlations.


2006 ◽  
Vol 129 (8) ◽  
pp. 958-965 ◽  
Author(s):  
Yirong Jiang ◽  
Biswajit Mitra ◽  
Srinivas Garimella ◽  
Ulf C. Andresen

This paper presents the results of an experimental study on condensation heat transfer of refrigerant blends R404A and R410A flowing through horizontal tubes of 9.4 and 6.2mm inner diameter at nominal pressures of 80% and 90% of the critical pressure. Local heat transfer coefficients were measured for the mass flux range 200<G<800kg∕m2‐s in small quality increments over the entire vapor-liquid region. Heat transfer coefficients increased with quality and mass flux, while the effect of reduced pressure was not very significant within this range of pressures. The heat transfer coefficients increased with a decrease in diameter.


1960 ◽  
Vol 82 (3) ◽  
pp. 189-196 ◽  
Author(s):  
M. Altman ◽  
R. H. Norris ◽  
F. W. Staub

A test facility is described that has been constructed to investigate local heat transfer and pressure drop for evaporating or condensing refrigerants. The empirical method of B. Pierre [1] for correlating the average heat-transfer coefficients of refrigerants evaporating in horizontal tubes is presented in conjunction with the data of several authors [3–6]. Data on local heat-transfer coefficients and pressure drop are presented for Refrigerant-22 evaporating in two 4-ft-long, 0.343-in-ID straight horizontal tubes, and are correlated by a refinement of the curve proposed in [1]. The procedure of Martinelli-Nelson [9] correlated the data for local pressure drop within 15 per cent.


Author(s):  
Joshua L. Nickerson ◽  
Martin Cerza ◽  
Sonia M. F. Garcia

The solution of the heat conduction equation in the liquid layer beneath a moving bubble’s base and the resulting local heat transfer coefficient are presented. An analytical model was constructed using separation of variables to solve the heat conduction equation for the thermal profile in the liquid film beneath the base of a bubble moving through a microchannel at a given velocity. Differentiating the resulting liquid thermal profile and applying the standard definition for the local heat transfer coefficient resulted in a solution for local heat transfer coefficient as a function of bubble length. Analysis included varying pertinent parameters such as film thickness beneath the bubble base, wall heat flux, and superheated temperature in the microchannel. Water and FC-72 were analyzed as prospective coolant fluids. Analytical data revealed that as the superheated temperature in the microchannel increases, local heat transfer coefficients increase and arrive at a higher steady-state value. Increasing wall heat flux achieved the same result, while increasing film thickness resulted in lower heat transfer coefficients. The model indicated that water had superior performance as a coolant, provided the dielectric fluid (FC-72) is not mandated.