Optimal Linear-Quadratic Integral Feedback Controller Design With Disturbance Rejection for Proton Exchange Membrane Fuel Cell

Author(s):  
Milos Milanovic ◽  
Verica Radisavljevic-Gajic

This paper presents, a novel controller design technique that can be used for the Proton Exchange Membrane Fuel Cell to tackle the impact of the sudden stack current disturbances. The proposed controller design consists of three components: a full-state feedback control loop, an integral of error control loop and a feed-forward control loop. The feed-forward control loop is designed to ease the impact of the piecewise continuous current disturbance on the stack voltage. Linearized system matrices are set up in such a way that a new augmented system is formed. Controller gains are calculated by using a quadratic performance criterion which is minimized along the trajectories of the augmented system. Simulation results are presented and discussed.

Author(s):  
Salar Imanmehr ◽  
Nader Pourmahmod

In this research, the impact of structural parameters of bipolar plates on the proton exchange membrane (PEM) fuel cell performance has been investigated using numerical method, and this model incorporates all the essential fundamental physical and electrochemical processes occurring in the membrane electrolyte, cathode catalyst layer, electrode backing, and flow channel, with some assumptions in each part. In formulation of this model, the cell is assumed to work under steady state conditions. Also, since the thickness of the cell is negligible compared to other dimensions, one-dimensional and isothermal approximations are used. The structural parameters considered in this paper are: the width of channels (Wc), the width of support (Ws), the number of gas channels (ng), the height of channels (hc), and the height of supports (hp). The results show that structural parameters of bipolar plates have a great impact on outlet voltage in high current densities. Also, the number of gas channels, their surface area, the contacting area of bipolar plates, and electrodes have a great effect on the rate of reaction and consequently on outlet voltage. The model predictions have been compared with the existing experimental results available in the literature, and excellent agreement has been demonstrated between the model results and the experimental data for the cell polarization curve.


2017 ◽  
Vol 142 ◽  
pp. 1661-1667 ◽  
Author(s):  
Aleksandra Sveshnikova ◽  
Gioele Di Marcoberardino ◽  
Claudio Pirrone ◽  
Aldo Bischi ◽  
Gianluca Valenti ◽  
...  

2009 ◽  
Vol 21 (5) ◽  
pp. 673-692 ◽  
Author(s):  
Cristina Iojoiu ◽  
Jean-Yves Sanchez

This paper is a review that is focused on ionomers based on aromatic polysulfone backbone and intended to be used in proton exchange membrane fuel cells or in direct methanol fuel cells. Emphasis is placed on the different chemical routes to prepare the ionomers. Special attention is given to the impact of the ionomer structure on the conductivity performance and on the dimensional stability of the membranes at high temperatures.


Membranes ◽  
2021 ◽  
Vol 11 (5) ◽  
pp. 366
Author(s):  
Mylène Robert ◽  
Assma El Kaddouri ◽  
Jean-Christophe Perrin ◽  
Kévin Mozet ◽  
Jérôme Dillet ◽  
...  

A proton-exchange membrane fuel cell (PEMFC) constitutes today one of the preferred technologies to promote hydrogen-based alternative energies. However, the large-scale deployment of PEMFCs is still hampered by insufficient durability and reliability. In particular, the degradation of the polyelectrolyte membrane, caused by harsh mechanical and chemical stresses experienced during fuel cell operation, has been identified as one of the main factors restricting the PEMFC lifetime. An innovative chemical-mechanical ex situ aging device was developed to simultaneously expose the membrane to mechanical fatigue and an oxidizing environment (i.e., free radicals) in order to reproduce conditions close to those encountered in fuel cell systems. A cyclic compressive stress of 5 or 10 MPa was applied during several hours while a degrading solution (H2O2 or a Fenton solution) was circulated in contact with the membrane. The results demonstrated that both composite Nafion™ XL and non-reinforced Nafion™ NR211 membranes are significantly degraded by the conjoint mechanical and chemical stress exposure. The fluoride emission rate (FER) was generally slightly lower with XL than with NR211, which could be attributed to the degradation mitigation strategies developed for composite XL, except when the pressure level or the aging duration were increased, suggesting a limitation of the improved durability of XL.


Sign in / Sign up

Export Citation Format

Share Document