CFD Aided Design of Heat Transfer Plates for Gasketed Plate Heat Exchangers

Author(s):  
Ece Özkaya ◽  
Selin Aradag ◽  
Sadik Kakac

In this study, three-dimensional computational fluid dynamics (CFD) analyses are performed to assess the thermal-hydraulic characteristics of a commercial Gasketed Plate Heat Exchangers (GPHEx) with 30 degrees of chevron angle (Plate1). The results of CFD analyses are compared with a computer program (ETU HEX) previously developed based on experimental results. Heat transfer plate is scanned using photogrammetric scan method to model GPHEx. CFD model is created as two separate flow zones, one for each of hot and cold domains with a virtual plate. Mass flow inlet and pressure outlet boundary conditions are applied. The working fluid is water. Temperature and pressure distributions are obtained for a Reynolds number range of 700–3400 and total temperature difference and pressure drop values are compared with ETU HEX. A new plate (Plate2) with corrugation pattern using smaller amplitude is designed and analyzed. The thermal properties are in good agreement with experimental data for the commercial plate. For the new plate, the decrease of the amplitude leads to a smaller enlargement factor which causes a low heat transfer rate while the pressure drop remains almost constant.

2020 ◽  
Vol 24 (1 Part A) ◽  
pp. 355-365
Author(s):  
Koray Karabulut

Plate heat exchangers have a widespread usage and the simplest parallel plate channel structures. Cross-corrugated ducts are basic channel geometries used in the plate heat exchangers. In this study, the increasing of heat transfer from the cross-corrugated triangular ducts by inserting triangular baffles with different placement angles into the channel upper side and pressure drop have been numerically investigated. Numerical calculations have been carried out to solve Navier-Stokes and energy equations by employing k-? turbulence model as 3-D and steady with ANSYS-FLUENT program. While inlet temperature of the air used as working fluid is 293 K, constant surface temperature values of the the lower corrugated channel walls are 373 K. The height of the baffle and apex angle of the corrugated duct have been taken constant as 0.5 H and 60?, respectively. Investigated Reynolds number range is 1000-6000 while the baffle placement angles are 30?, 45?, 60?, and 90?. Numerical results of this study are within 3.53% deviation with experimental study existed in literature. The obtained results have been presented as mean Nusselt number temperature and pressure variations of the fluid for each baffle angle. The temperature and velocity vector contour distributions have been also assessed for different Reynolds numbers and baffle angles. The value of the Num for the corrugated channel with 60? baffle angle is 8.2% higher than that of the 90? for the Re = 4000. Besides, for Re = 1000 the value of the pressure drop is 39% lower in the channel with 60? baffle angle than that of 90?.


Author(s):  
Wen Fu ◽  
Xizhen Ma ◽  
Peiyue Li ◽  
Minghui Zhang ◽  
Sheng Li

Printed circuit heat exchangers are considered for use as the intermediate heat exchangers (IHXs) in high temperature gas-cooled reactors (HTGRs), molten salts reactors (MSRs) and other advanced reactors. A printed circuit heat exchanger (PCHE) is a highly integrated plate-type compact heat exchanger with high-temperature, high-pressure applications and high compactness. A PCHE is built based on the technology of chemical etching and diffusion bonding. A PCHE with supercritical carbon dioxide (CO2) as the working fluid was designed in this study based on the theory correlations. Three-dimensional numerical analysis was then conducted to investigate the heat transfer and pressure drop characteristics of supercritical CO2 in the designed printed circuit heat exchanger using commercial CFD code, FLUENT. The distributions of temperature and velocity through the channel were modeled. The influences of Reynolds number on heat transfer and pressure drop were analyzed. The numerical results agree well with the theory calculations.


2013 ◽  
Vol 465-466 ◽  
pp. 500-504 ◽  
Author(s):  
Shahrin Hisham Amirnordin ◽  
Hissein Didane Djamal ◽  
Mohd Norani Mansor ◽  
Amir Khalid ◽  
Md Seri Suzairin ◽  
...  

This paper presents the effect of the changes in fin geometry on pressure drop and heat transfer characteristics of louvered fin heat exchanger numerically. Three dimensional simulation using ANSYS Fluent have been conducted for six different configurations at Reynolds number ranging from 200 to 1000 based on louver pitch. The performance of this system has been evaluated by calculating pressure drop and heat transfer coefficient. The result shows that, the fin pitch and the louver pitch have a very considerable effect on pressure drop as well as heat transfer rate. It is observed that increasing the fin pitch will relatively result in an increase in heat transfer rate but at the same time, the pressure drop will decrease. On the other hand, low pressure drop and low heat transfer rate will be obtained when the louver pitch is increased. Final result shows a good agreement between experimental and numerical results of the louvered fin which is about 12%. This indicates the capability of louvered fin in enhancing the performance of heat exchangers.


Author(s):  
Josua P. Meyer ◽  
Leon Liebenberg ◽  
Jonathan A. Olivier

Heat exchangers are usually designed in such a way that they do not operate in the transition region. This is usually due to a lack of information in this region. However, due to design constraints, energy efficiency requirements or change of operating conditions, heat exchangers are often forced to operate in this region. It is also well known that entrance disturbances influence where transition occurs. The purpose of this paper is to present experimental heat transfer and pressure drop data in the transition region for fully developed and developing flows inside smooth tubes using water as the working fluid. The use of different inlet disturbances were used to investigate its effect on transition. A tube-in-tube heat exchanger was used to perform the experiments, which ranged in Reynolds numbers from 1 000 to 20 000, with Prandtl numbers being between 4 and 6 while Grashof numbers were in the order of 105. Results showed that the type of inlet disturbance could delay transition to a Reynolds number as high as 7 000, while other inlets expedited it, confirming results of others. For heat transfer, though, it was found that transition was independent of the inlet disturbance and all commenced at the same Reynolds number, 2 000–3 000, which was attributed to secondary flow effects.


Author(s):  
Jianchang Huang ◽  
Thomas J. Sheer ◽  
Michael Bailey-McEwan

The heat transfer and pressure drop characteristics of plate heat exchangers were measured, when used as refrigerant liquid over-feed evaporators. The three units all had 24 plates but with different chevron-angle combinations of 28°/28°, 28°/60°, and 60°/60°. R134a flowing upwards was used as the refrigerant, in a counter-current arrangement with water flowing on the other side. Heat transfer and pressure drop measurements were made over a range of mass flux, heat flux and corresponding outlet vapour fractions. The effect of system pressure on the evaporator performance was not evaluated due to the small range of evaporating temperature. Experimental data were reduced to obtain the refrigerant-side heat transfer coefficient and frictional pressure drop. The results for heat transfer showed a strong dependence on heat flux and weak dependence on mass flux and vapour fraction. Furthermore, the chevron angle had a small influence on heat transfer but a large influence on frictional pressure drops. Along with observations that were obtained previously on large ammonia and R12 plate evaporators, it is concluded that the dominating heat transfer mechanism in this type of evaporator is nucleate-boiling rather than forced convection. For the two-phase friction factor, various established methods were evaluated; the homogeneous treatment gives good agreement.