Performance of Plate Heat Exchangers Used as Refrigerant Liquid-Overfeed Evaporators

Author(s):  
Jianchang Huang ◽  
Thomas J. Sheer ◽  
Michael Bailey-McEwan

The heat transfer and pressure drop characteristics of plate heat exchangers were measured, when used as refrigerant liquid over-feed evaporators. The three units all had 24 plates but with different chevron-angle combinations of 28°/28°, 28°/60°, and 60°/60°. R134a flowing upwards was used as the refrigerant, in a counter-current arrangement with water flowing on the other side. Heat transfer and pressure drop measurements were made over a range of mass flux, heat flux and corresponding outlet vapour fractions. The effect of system pressure on the evaporator performance was not evaluated due to the small range of evaporating temperature. Experimental data were reduced to obtain the refrigerant-side heat transfer coefficient and frictional pressure drop. The results for heat transfer showed a strong dependence on heat flux and weak dependence on mass flux and vapour fraction. Furthermore, the chevron angle had a small influence on heat transfer but a large influence on frictional pressure drops. Along with observations that were obtained previously on large ammonia and R12 plate evaporators, it is concluded that the dominating heat transfer mechanism in this type of evaporator is nucleate-boiling rather than forced convection. For the two-phase friction factor, various established methods were evaluated; the homogeneous treatment gives good agreement.

Energies ◽  
2021 ◽  
Vol 14 (18) ◽  
pp. 5972
Author(s):  
Yu Xu ◽  
Zihao Yan ◽  
Ling Li

To protect the environment, a new low-GWP refrigerant R1234ze(E) was created to substitute R134a. However, its flow boiling performances have not received sufficient attention so far, which hinders its popularization to some extent. In view of this, an experimental investigation was carried out in a 1.88 mm horizontal circular minichannel. The saturation pressures were maintained at 0.6 and 0.7 MPa, accompanied by mass flux within 540–870 kg/m2 s and heat flux within 25–65 kW/m2. For nucleate boiling, a larger heat flux brings about a larger heat transfer coefficient (HTC), while for convective boiling, the mass flux and vapor quality appear to take the lead role. The threshold vapor quality of different heat transfer mechanisms is around 0.4. Additionally, larger saturation pressure results in large HTC. As for the frictional pressure drop (FPD), it is positively influenced by mass flux and vapor quality, while negatively affected by saturation pressure, and the influence of heat flux is negligible. Furthermore, with the measured data, several existing correlations are compared. The results indicate that the correlations of Saitoh et al. (2007) and Müller-Steinhagen and Heck (1986) perform best on flow boiling HTC and FPD with mean absolute deviations of 5.4% and 10.9%.


Author(s):  
Han Wang ◽  
Qincheng Bi ◽  
Linchuan Wang ◽  
Haicai Lv ◽  
Laurence K. H. Leung

An experiment has recently been performed at Xi’an Jiaotong University to study the wall temperature and pressure drop at supercritical pressures with upward flow of water inside a 2×2 rod bundle. A fuel-assembly simulator with four heated rods was installed inside a square channel with rounded corner. The outer diameter of each heated rod is 8 mm with an effective heated length of 600 mm. Experimental parameters covered the pressure of 23–28 MPa, mass flux of 350–1000 kg/m2s and heat flux on the rod surface of 200–1000 kW/m2. According to the experimental data, it was found that the circumferential wall temperature distribution of a heated rod is not uniform. The temperature difference between the maximum and the minimum varies with heat flux and/or mass flux. Heat transfer characteristics of supercritical water in bundle were discussed with respect to various heat fluxes. The effect of heat flux on heat transfer in rod bundles is similar with that in tubes or annuli. In addition, flow resistance reflected in the form of pressure loss has also been studied. Experimental results showed that the total pressure drop increases with bulk enthalpy and mass flux. Four heat transfer correlations developed for supercritical pressures water were compared with the present test data. Predictions of Jackson correlation agrees closely with the experimental data.


Author(s):  
Ece Özkaya ◽  
Selin Aradag ◽  
Sadik Kakac

In this study, three-dimensional computational fluid dynamics (CFD) analyses are performed to assess the thermal-hydraulic characteristics of a commercial Gasketed Plate Heat Exchangers (GPHEx) with 30 degrees of chevron angle (Plate1). The results of CFD analyses are compared with a computer program (ETU HEX) previously developed based on experimental results. Heat transfer plate is scanned using photogrammetric scan method to model GPHEx. CFD model is created as two separate flow zones, one for each of hot and cold domains with a virtual plate. Mass flow inlet and pressure outlet boundary conditions are applied. The working fluid is water. Temperature and pressure distributions are obtained for a Reynolds number range of 700–3400 and total temperature difference and pressure drop values are compared with ETU HEX. A new plate (Plate2) with corrugation pattern using smaller amplitude is designed and analyzed. The thermal properties are in good agreement with experimental data for the commercial plate. For the new plate, the decrease of the amplitude leads to a smaller enlargement factor which causes a low heat transfer rate while the pressure drop remains almost constant.


Author(s):  
Hyun Jin Kim ◽  
Leon Liebenberg ◽  
Anthony M. Jacobi

An experimental investigation was performed to study the heat transfer and pressure drop characteristics of refrigerant R-134a boiling in a chevron-patterned brazed plate heat exchanger (BPHE) at low mass flux. The heat transfer coefficient and pressure drop characteristics are analyzed in relation to varying mass flux (30–50 kgm−2s−1), saturation pressure (675 kPa and 833 kPa), heat flux (0.8 and 2.5 kWm−2), and vapor quality (0.1–0.9). The two-phase pressure drop shows a strong dependence on mass flux and significant saturation temperature drop at high mass flux. The two-phase heat transfer coefficient was both strongly dependent on heat flux (at vapor qualities below 0.4) and on mass flux (at vapor qualities above 0.4). There was also apparent dryout, as depicted by decreased heat transfer at high vapor qualities. These observations suggest that both nucleate and convective boiling mechanisms prevailed. Existing transition correlations however suggest that the experimental data is rather convection-dominant and not a mix of convection and nucleate boiling. The experimental data further strongly suggest the prevalence of both macrochannel and minichannel type flows. Several acknowledged semi-empirical transition criteria were employed to verify our observations. These criteria mostly support our observations that R-134a evaporating at low mass fluxes in a BPHE with a hydraulic diameter of 3.4 mm, has heat transfer and pressure drop characteristics typically indicative of macrochannel as well as minichannel flows. Disagreement however exists with accepted correlations regarding the prevalence of convective or nucleate boiling.


1959 ◽  
Vol 81 (1) ◽  
pp. 43-52 ◽  
Author(s):  
Kurt Engelberg-Forster ◽  
R. Greif

Various heat-transfer mechanisms which have been previously proposed are analyzed in the light of recent experiments. Evidence is presented in favor of a vapor-liquid exchange mechanism. The vapor-liquid exchange mechanism is shown to explain the insensitivity of boiling heat flux to the level of subcooling. A “Reynolds’ analogy” for nucleate boiling is presented in some detail. A procedure is given for calculating the superheat at which the liquid bulk velocity ceases to contribute to the heat flux. An expression for the growth of a vapor bubble in a highly superheated liquid is deduced. A method is presented which allows the deduction of correlations for nucleate boiling which give the dependence of heat flux on superheat and system pressure. Two such correlations are presented and results are compared with experiment. It is shown that one correlation yields the heat flux for different liquids varying from water to mercury, without necessitating any change in constant or exponent of the correlation.