Sizing Directional Pneumatic Valves Based on the Characteristic Dynamic Behavior of Linear Actuators

2021 ◽  
Author(s):  
Vinícius Vigolo ◽  
Antonio Carlos Valdiero ◽  
Victor Juliano De Negri

Abstract In this paper, a novel approach to size directional pneumatic valves based on the analysis of the characteristic behavior of pneumatic actuators applied for pick and place tasks is presented. The study evidences the existence of three characteristic times in the displacement of a standard pneumatic actuation system, which are the emptying time, the transient-state time, and the steady-state time. The results also indicate that there is a close correlation between the velocity profile and the relative size of the piston area, where the steady-state time might be negligible when the piston is correctly sized. The emptying time, characterized by the depressurization of the counterpressure chamber, occurs predominantly with choked mass flow rate and constant volume. In this way, an analytical equation to estimate the emptying time has been determined. Moreover, during the transient-state time, the velocity profile is similar to the characteristic behavior of a first order system, therefore, the transient-state time is estimated by the time constant of the system, which was obtained by a linear first order model developed using the fundamental equations that govern the system behavior. The total displacement time, which is a design requirement to size directional valves, can be expressed as the sum of the emptying and transient-state time. Consequently, a set of equations are proposed to size the directional valve using design parameters such as displacement time, piston volume, load force, and supply pressure. The proposed equations were evaluated along with simulation and experimental results, demonstrating their validity and accuracy.

Author(s):  
Heru Dibyo Laksono

This journal discusses the design and analysis of the transfer response of the direct cuurent type of Automatic Voltage Regulator (AVR) system with 2 degrees of freedom controller. Direct current type of the AVR system is represented in the form of transfer function. For 2 degrees of freedom controllers are designed using a parallel architecture with the help of Matlab software using predefined design criteria. The types of controllers used consist of Proportional Differential (PD), Proportional Integral (PI), Proportional Integral Differential (PID), Proportional Differential with First Order Filters in the Differential Section (PDF) and Proportional Intregral Differential with First Order Filters in the Differential Section (PIDF). For the transition analysis, the observed parameters consist of rise time, peak time, steady state time, maximum pass value and peak value. The results of the analysis show that the controller that meets the design criteria is a Proportional Differential (PD) controller with an uptime parameter value of 0.2808 seconds, a peak time of 1.3354 seconds, a steady state time of 0.7017 seconds, a maximum pass of 0% and a peak value of 0.9512. For the Proportional Differential controller with First Order Filter in the Differential Section (PDF) with an increase time parameter value of 0.4177 seconds, a peak time of 1.4684 seconds, a steady state time of 0.8453 seconds, a maximum pass of 0% and a peak value of 0.9502.


2020 ◽  
Vol 105 (5) ◽  
pp. 893-903 ◽  
Author(s):  
Claire V. Burley ◽  
Rebekah A. I. Lucas ◽  
Anna C. Whittaker ◽  
Karen Mullinger ◽  
Samuel J. E. Lucas

Sign in / Sign up

Export Citation Format

Share Document