High Rotation Number Effect on Heat Transfer in a Leading Edge Cooling Channel With Three Channel Orientations

Author(s):  
Szu-Chi Huang ◽  
Yao-Hsien Liu

Heat transfer in a leading edge, triangular shaped cooling channel with three channel orientations under high rotation numbers is experimentally studied. Continuous ribs and V-shaped ribs, both at 45° rib angle of attack, are applied on the leading and trailing surfaces. For each rib case, three channel orientations (90°, 67.5°, and 45°) with respect to the plane of rotation are tested. The rib height to hydraulic diameter ratio (e/Dh) is 0.085 and the rib pitch to height ratio (P/e) is 9. Reynolds numbers are from 15000 to 25000, and the rotation numbers are from 0 to 0.65. Results show that the heat transfer variation is influenced by the combined effects of rib configuration and channel orientation. Effect of channel orientation influences local heat transfer distribution inside this triangular channel, and heat transfer is enhanced gradually on the leading surface when the channel orientation varies from 90° to 45° for both ribbed cases in this study.

1991 ◽  
Vol 113 (4) ◽  
pp. 843-850 ◽  
Author(s):  
A. B. Mehendale ◽  
J. C. Han ◽  
S. Ou

The influence of high mainstream turbulence on leading edge heat transfer was studied. High mainstream turbulence was produced by a bar grid (Tu = 3.3–5.1 percent), passive grid (Tu = 7.6–9.7 percent), and jet grid (Tu = 12.9–15.2 percent). Experiments were performed using a blunt body with a semicylinder leading edge and flat sidewalls. The mainstream Reynolds numbers based on leading edge diameter were 25,000, 40,000, and 100,000. Spanwise and streamwise distributions of local heat transfer coefficients on the leading edge and flat sidewall were obtained. The results indicate that the leading edge heat transfer increases significantly with increasing mainstream turbulence intensity, but the effect diminishes at the end of the flat sidewall because of turbulence decay. Stagnation point heat transfer results for high turbulence intensity flows agree with the Lowery and Vachon correlation, but the overall heat transfer results for the leading edge quarter-cylinder region are higher than their overall correlation for the entire circular cylinder region. High mainstream turbulence tends not to shift the location of the separation-reattachment region. The reattachment heat transfer results are about the same regardless of mainstream turbulence levels and are much higher than the turbulent flat plate correlation.


Author(s):  
Shou-Shing Hsieh ◽  
Ming-Hung Chiang ◽  
Ping-Ju Chen

The influence of rotation and uneven wall heat flux effect on the local velocity distribution as well as local heat transfer coefficient in a rotating, two pass rib roughened (rib height e/DH = 0.20; rib pitch p/e = 5) square channel were studied for Reynolds numbers from 5000 to 10000 and rotation numbers from 0 to 0.1602 (≤ 300 rpm). The measured mean velocity under different wall heat flux condition for the specified rib configuration at ReH = 5000 and 10000, ReH = 0, 267, 534 and 801 are presented. Regionally averaged Nusselt number variations with rotation (≤ 800 rpm)along the duct have been determined over the trailing and leading surfaces for a two pass channel. Moreover, LDV measurements with heating were examined. It was found that the Coriolis force as well as centrifugal buoyancy is significant as the rotational speed increases.


Author(s):  
Szu-Chi Huang ◽  
Yao-Hsien Liu

Heat transfer in a leading edge, triangular-shaped cooling channel with three channel orientations under high rotation numbers is investigated in this study. Continuous ribs and V-shaped ribs (P/e = 9, e/Dh = 0.085), both placed at an angle (α = 45 deg) to the mainstream flow, are applied on the leading and trailing surfaces. The Reynolds number range is 15,000–25,000 and the rotation number range is 0–0.65. Effects of high rotation number on heat transfer with three angles of rotation (90 deg, 67.5 deg, and 45 deg) are tested. Results show that heat transfer is influenced by the combined effects of rib and channel orientation. When the rotation number is smaller than 0.4, rotation causes a decrease in the average Nusselt number ratios on the leading surface at a channel orientation of 90 deg. Heat transfer is enhanced gradually on the leading surface when the channel orientation varies from 90 deg to 45 deg for both ribbed cases. The highest heat transfer enhancement due to rotation is found at the highest rotation number of 0.65.


1967 ◽  
Vol 89 (2) ◽  
pp. 163-167 ◽  
Author(s):  
E. G. Filetti ◽  
W. M. Kays

Experimental data are presented for local heat transfer rates near the entrance to a flat duct in which there is an abrupt symmetrical enlargement in flow cross section. Two enlargement area ratios are considered, and Reynolds numbers, based on duct hydraulic diameter, varied from 70,000 to 205,000. It is found that such a flow is characterized by a long stall on one side and a short stall on the other. Maximum heat transfer occurs in both cases at the point of reattachment, followed by a decay toward the values for fully developed duct flow. Empirical equations are given for the Nusselt number at the reattachment point, correlated as functions of duct Reynolds number and enlargement ratio.


1994 ◽  
Vol 116 (1) ◽  
pp. 133-140 ◽  
Author(s):  
S. Mochizuki ◽  
J. Takamura ◽  
S. Yamawaki ◽  
Wen-Jei Yang

Heat transfer characteristics of a three-pass serpentine flow passage with rotation are experimentally studied. The walls of the square flow passage are plated with thin stainless-steel foils through which electrical current is applied to generate heat. The local heat transfer performance on the four side walls of the three straight flow passages and two turning elbows are determined for both stationary and rotating cases. The throughflow Reynolds, Rayleigh (centrifugal type), and rotation numbers are varied. It is revealed that three-dimensional flow structures cause the heat transfer rate at the bends to be substantially higher than at the straight flow passages. This mechanism is revealed by means of a flow visualization experiment for a nonrotating case. Along the first straight flow passage, the heat transfer rate is increased on the trailing surface but is reduced on the leading surface, due to the action of secondary streams induced by the Coriolis force. At low Reynolds numbers, the local heat transfer performance is primarily a function of buoyancy force. In the higher Reynolds number range, however, the circumferentially averaged Nusselt number is only a weak function of the Rayleigh and rotation numbers.


2009 ◽  
Vol 131 (7) ◽  
Author(s):  
Akhilesh P. Rallabandi ◽  
Huitao Yang ◽  
Je-Chin Han

Systematic experiments are conducted to measure heat transfer enhancement and pressure loss characteristics on a square channel (simulating a gas turbine blade cooling passage) with two opposite surfaces roughened by 45 deg parallel ribs. Copper plates fitted with a silicone heater and instrumented with thermocouples are used to measure regionally averaged local heat transfer coefficients. Reynolds numbers studied in the channel range from 30,000 to 400,000. The rib height (e) to hydraulic diameter (D) ratio ranges from 0.1 to 0.18. The rib spacing (p) to height ratio (p/e) ranges from 5 to 10. Results show higher heat transfer coefficients at smaller values of p/e and larger values of e/D, though at the cost of higher friction losses. Results also indicate that the thermal performance of the ribbed channel falls with increasing Reynolds numbers. Correlations predicting Nusselt number (Nu) and friction factor (f¯) as a function of p/e, e/D, and Re are developed. Also developed are correlations for R and G (friction and heat transfer roughness functions, respectively) as a function of the roughness Reynolds number (e+), p/e, and e/D.


1987 ◽  
Vol 109 (1) ◽  
pp. 43-48 ◽  
Author(s):  
J. W. Baughn ◽  
H. Iacovides ◽  
D. C. Jackson ◽  
B. E. Launder

The paper reports extensive connective heat transfer data for turbulent flow of air around a U-bend with a ratio of bend radius:pipe diameter of 3.375:1. Experiments cover Reynolds numbers from 2 × 104 to 1.1 × 105. Measurements of local heat transfer coefficient are made at six stations and at five circumferential positions at each station. At Re = 6 × 104 a detailed mapping of the temperature field within the air is made at the same stations. The experiment duplicates the flow configuration for which Azzola and Humphrey [3] have recently reported laser-Doppler measurements of the mean and turbulent velocity field. The measurements show a strong augmentation of heat transfer coefficient on the outside of the bend and relatively low levels on the inside associated with the combined effects of secondary flow and the amplification/suppression of turbulent mixing by streamline curvature. The peak level of Nu occurs halfway around the bend at which position the heat transfer coefficient on the outside is about three times that on the inside. Another feature of interest is that a strongly nonuniform Nu persists six diameters downstream of the bend even though secondary flow and streamline curvature are negligible there. At the entry to the bend there are signs of partial laminarization on the inside of the bend, an effect that is more pronounced at lower Reynolds numbers.


1993 ◽  
Vol 115 (3) ◽  
pp. 560-567 ◽  
Author(s):  
N. Zhang ◽  
J. Chiou ◽  
S. Fann ◽  
W.-J. Yang

Experiments are performed to determine the local heat transfer performance in a rotating serpentine passage with rib-roughened surfaces. The ribs are placed on the trailing and leading walls in a corresponding posited arrangement with an angle of attack of 90 deg. The rib height-to-hydraulic diameter ratio, e/Dh, is 0.0787 and the rib pitch-to-height ratio, s/e, is 11. The throughflow Reynolds number is varied, typically at 23,000, 47,000, and 70,000 in the passage both at rest and in rotation. In the rotation cases, the rotation number is varied from 0.023 to 0.0594. Results for the rib-roughened serpentine passages are compared with those of smooth ones in the literature. Comparison is also made on results for the rib-roughened passages between the stationary and rotating cases. It is disclosed that a significant enhancement is achieved in the heat transfer in both the stationary and rotating cases resulting from an installation of the ribs. Both the rotation and Rayleigh numbers play important roles in the heat transfer performance on both the trailing and leading walls. Although the Reynolds number strongly influences the Nusselt numbers in the rib-roughened passage of both the stationary and rotating cases, Nuo and Nu, respectively, it has little effect on their ratio Nu/Nuo.


2001 ◽  
Author(s):  
Lamyaa A. El-Gabry ◽  
Deborah A. Kaminski

Abstract Measurements of the local heat transfer distribution on smooth and roughened surfaces under an array of angled impinging jets are presented. The test rig is designed to simulate impingement with cross-flow in one direction which is a common method for cooling gas turbine components such as the combustion liner. Jet angle is varied between 30, 60, and 90 degrees as measured from the impingement surface, which is either smooth or randomly roughened. Liquid crystal video thermography is used to capture surface temperature data at five different jet Reynolds numbers ranging between 15,000 and 35,000. The effect of jet angle, Reynolds number, gap, and surface roughness on heat transfer efficiency and pressure loss is determined along with the various interactions among these parameters. Peak heat transfer coefficients for the range of Reynolds number from 15,000 to 35,000 are highest for orthogonal jets impinging on roughened surface; peak Nu values for this configuration ranged from 88 to 165 depending on Reynolds number. The ratio of peak to average Nu is lowest for 30-degree jets impinging on roughened surfaces. It is often desirable to minimize this ratio in order to decrease thermal gradients, which could lead to thermal fatigue. High thermal stress can significantly reduce the useful life of engineering components and machinery. Peak heat transfer coefficients decay in the cross-flow direction by close to 24% over a dimensionless length of 20. The decrease of spanwise average Nu in the crossflow direction is lowest for the case of 30-degree jets impinging on a roughened surface where the decrease was less than 3%. The decrease is greatest for 30-degree jet impingement on a smooth surface where the stagnation point Nu decreased by more than 23% for some Reynolds numbers.


Author(s):  
J.-J. Hwang ◽  
C.-S. Cheng ◽  
Y.-P. Tsia

An experimental study has been performed to measure local heat transfer coefficients and static well pressure drops in leading-edge triangular ducts cooled by wall/impinged jets. Coolant provided by an array of equally spaced wall jets is aimed at the leading-edge apex and exits from the radial outlet. Detailed heat transfer coefficients are measured for the two walls forming the apex using transient liquid crystal technique. Secondary-flow structures are visualized to realize the mechanism of heat transfer enhancement by wall/impinged jets. Three right-triangular ducts of the same altitude and different apex angles of β = 30 deg (Duct A), 45 deg (Duct B) and 60 deg (Duct C) are tested for various jet Reynolds numbers (3000≦Rej≦12600) and jet spacings (s/d = 3.0 and 6.0). Results show that an increase in Rej increases the heat transfer on both walls. Local heat transfer on both walls gradually decreases downstream due to the crossflow effect. At the same Rej, the Duct C has the highest wall-averaged heat transfer because of the highest jet center velocity as well as the smallest jet inclined angle. Moreover, the distribution of static pressure drop based on the local through flow rate in the present triangular duct is similar to that that of developing straight pipe flows. Average jet Nusselt numbers on the both walls have been correlated with jet Reynolds number for three different duct shapes.