Heat Transfer Enhancement in Triangular Ducts With an Array of Side-Entry Wall/Impinged Jets

Author(s):  
J.-J. Hwang ◽  
C.-S. Cheng ◽  
Y.-P. Tsia

An experimental study has been performed to measure local heat transfer coefficients and static well pressure drops in leading-edge triangular ducts cooled by wall/impinged jets. Coolant provided by an array of equally spaced wall jets is aimed at the leading-edge apex and exits from the radial outlet. Detailed heat transfer coefficients are measured for the two walls forming the apex using transient liquid crystal technique. Secondary-flow structures are visualized to realize the mechanism of heat transfer enhancement by wall/impinged jets. Three right-triangular ducts of the same altitude and different apex angles of β = 30 deg (Duct A), 45 deg (Duct B) and 60 deg (Duct C) are tested for various jet Reynolds numbers (3000≦Rej≦12600) and jet spacings (s/d = 3.0 and 6.0). Results show that an increase in Rej increases the heat transfer on both walls. Local heat transfer on both walls gradually decreases downstream due to the crossflow effect. At the same Rej, the Duct C has the highest wall-averaged heat transfer because of the highest jet center velocity as well as the smallest jet inclined angle. Moreover, the distribution of static pressure drop based on the local through flow rate in the present triangular duct is similar to that that of developing straight pipe flows. Average jet Nusselt numbers on the both walls have been correlated with jet Reynolds number for three different duct shapes.

Author(s):  
Juan C. Adams ◽  
Peter T. Ireland ◽  
Martin Cerza ◽  
James Oswald

An effort is made to explain and improve the understanding of the mechanisms behind the thermo-hydraulic performance of perforated extended surfaces used in compact heat exchangers in the laminar flow regime (ReD = 400–2500). A transient liquid crystal technique, which uses Helium as operating fluid, together with digital image photographic processing have been used to provide measurements of local heat transfer coefficients for this geometry. This work has found that through the use of perforated surfaces there exists a local heat transfer enhancement benefit. It has also been found that although perforations cause a partial restart of the thermal boundary layer, a significant overall surface heat transfer enhancement may not be achieved over plain surfaces. It was also found that the distance between the fin’s leading edge and the point of last significant enhancement resulting from a perforation, linearly depends on Reynolds number. Local heat transfer coefficient measurements were validated by single blow experimentation of similar geometries. The transient single blow technique used the curve-matching method to compare predicted and experimental temperatures.


1994 ◽  
Vol 116 (4) ◽  
pp. 880-885 ◽  
Author(s):  
St. Tiggelbeck ◽  
N. K. Mitra ◽  
M. Fiebig

Longitudinal vortices can be generated in a channel flow by punching or mounting small triangular or rectangular pieces on the channel wall. Depending on their forms, these vortex generators (VG) are called delta wing, rectangular wing, pair of delta winglets, and pair of rectangular winglets. The heat transfer enhancement and the flow losses incurred by these four basic forms of VGs have been measured and compared in the Reynolds number range of 2000 to 9000 and for angles of attack between 30 and 90 deg. Local heat transfer coefficients on the wall have been measured by liquid crystal thermography. Results show that winglets perform better than wings and a pair of delta winglets can enhance heat transfer by 46 percent at Re=2000 to 120 percent at Re=8000 over the heat transfer on a plate.


1971 ◽  
Vol 93 (4) ◽  
pp. 461-468 ◽  
Author(s):  
J. A. Miller ◽  
P. F. Pucci

Local heat transfer coefficients to an airfoil in an oscillating stream have been measured for a range of frequencies and oscillation amplitudes. Results at moderate angles of attack are in agreement with previously reported findings. However, at large angles of attack, including those associated with stall in steady flow, a strong periodic starting vortex shed from the leading edge leads to a dramatic reattachment of the flow and consequent increase in local Nusselt Numbers of as much as five-fold. These effects are shown to be amplified by increasing oscillation frequency and amplitude.


2007 ◽  
Vol 129 (11) ◽  
pp. 1611-1615 ◽  
Author(s):  
H. S. Ahn ◽  
S. W. Lee ◽  
S. C. Lau

Experiments were conducted to determine the average heat transfer coefficients on three wall segments between blockages with holes in a wide rectangular channel. Eight different configurations of the holes in the blockages—two diameters and four aspect ratios of the holes—were examined. The pressure drops across the blockages were also measured. The results showed that the elongated holes in the blockages in this study enhanced more heat transfer than the round holes, but they also caused larger pressure drops across the blockages.


1991 ◽  
Vol 113 (4) ◽  
pp. 843-850 ◽  
Author(s):  
A. B. Mehendale ◽  
J. C. Han ◽  
S. Ou

The influence of high mainstream turbulence on leading edge heat transfer was studied. High mainstream turbulence was produced by a bar grid (Tu = 3.3–5.1 percent), passive grid (Tu = 7.6–9.7 percent), and jet grid (Tu = 12.9–15.2 percent). Experiments were performed using a blunt body with a semicylinder leading edge and flat sidewalls. The mainstream Reynolds numbers based on leading edge diameter were 25,000, 40,000, and 100,000. Spanwise and streamwise distributions of local heat transfer coefficients on the leading edge and flat sidewall were obtained. The results indicate that the leading edge heat transfer increases significantly with increasing mainstream turbulence intensity, but the effect diminishes at the end of the flat sidewall because of turbulence decay. Stagnation point heat transfer results for high turbulence intensity flows agree with the Lowery and Vachon correlation, but the overall heat transfer results for the leading edge quarter-cylinder region are higher than their overall correlation for the entire circular cylinder region. High mainstream turbulence tends not to shift the location of the separation-reattachment region. The reattachment heat transfer results are about the same regardless of mainstream turbulence levels and are much higher than the turbulent flat plate correlation.


2000 ◽  
Vol 122 (4) ◽  
pp. 669-678 ◽  
Author(s):  
J.-J. Hwang ◽  
B.-Y. Chang

Experiments are conducted to study the heat transfer and pressure drop characteristics in a triangular duct cooled by an array of tangential jets, simulating the leading-edge cooling circuit of a turbine blade. Coolant ejected from a high-pressure plenum through an array of orifices is aimed at the leading-edge apex and exits from the radial outlets. Three different outflow orientations, namely coincident with the entry flow, opposed to the entry flow, and both, are tested for various Reynolds numbers 12600⩽Re⩽42000. A transient liquid crystal technique is used to measure the detailed heat transfer coefficients on two walls forming the leading-edge apex. Flow rate across each jet hole and the crossflow development, which are closely related to the local heat transfer characteristics, are also measured. Results show that increasing Re increases the heat transfer on both walls. The outflow orientation affects significantly the local heat transfer characteristics through influencing the jet flow together with the crossflow in the triangular duct. The triangular duct with two openings is recommended since it has the highest wall-averaged heat transfer and the moderate loss coefficient among the three outflow orientations investigated. Correlations for wall-averaged Nusselt number and loss coefficient in the triangular duct have been developed by considering the Reynolds number for three different outflow orientations. [S0022-1481(00)01204-4]


Author(s):  
Yong-Jiun Lee ◽  
Poh-Seng Lee ◽  
Siaw-Kiang Chou

Oblique fins created in a microchannel heat sink can serve to modulate the flow, resulting in local and global heat transfer enhancement. Numerical analysis of laminar flow and heat transfer in such modified microchannel heat sink showed that significant enhancement of heat transfer can be achieved with negligible pressure drop penalty. The breakage of continuous fin into oblique sections causes the thermal boundary layers to be re-initialized at the leading edge of each oblique fin and reduces the boundary-layer thickness. This regeneration of the entrance effect causes the flow to be always in a developing state thus resulting in better heat transfer. In addition, the presence of the smaller oblique channels causes a fraction of the flow to branch into the adjacent main channels. The secondary flows thus created improve fluid mixing which serves to further enhance the heat transfer. The combination of the entrance and secondary flow effect results in a much improved heat transfer performance (the average and local heat transfer coefficients are enhanced by as much as 80%). Both the maximum wall temperature and temperature gradient are substantially decreased as a result.


2013 ◽  
Vol 34 (1) ◽  
pp. 5-16 ◽  
Author(s):  
Jozef Cernecky ◽  
Jan Koniar ◽  
Zuzana Brodnianska

Abstract The paper deals with a study of the effect of regulating elements on local values of heat transfer coefficients along shaped heat exchange surfaces with forced air convection. The use of combined methods of heat transfer intensification, i.e. a combination of regulating elements with appropriately shaped heat exchange areas seems to be highly effective. The study focused on the analysis of local values of heat transfer coefficients in indicated cuts, in distances expressed as a ratio x/s for 0; 0.33; 0.66 and 1. As can be seen from our findings, in given conditions the regulating elements can increase the values of local heat transfer coefficients along shaped heat exchange surfaces. An optical method of holographic interferometry was used for the experimental research into temperature fields in the vicinity of heat exchange surfaces. The obtained values correspond very well with those of local heat transfer coefficients αx, recorded in a CFD simulation.