Experimental Investigation on the Pipe Leakage

Author(s):  
Benan Cai ◽  
Qi Zhang ◽  
Yu Weng ◽  
Hongfang Gu ◽  
Haijun Wang

Pipelines are widely used in many fields including power industry, petroleum system etc. Pipelines such as the surge line and main pipe are easily subjected to thermal stratification as a result of the non-uniform temperature distribution in the nuclear power plants. Furthermore, pipelines can suffer from thermal fatigue in virtue of long-term uneven stress distribution. When the surge line or main pipe subjected to thermal stratification and thermal fatigue keeps operating for long time, the pipe leakage may happen because of the existence of pipeline crack. The thermal pipeline crack leakage mainly appears in the region with stress concentration. As the pipe system is always covered with thermal insulation layer in the actual nuclear power plants, it is hard for workers to observe pipeline leak, which can have a bad effect on the normal operation. Since the temperature and humidity close to the pipe crack due to leakage can change compared to the normal operation, we can infer from the temperature and humidity changes that the pipe leakage occurs. Based on this idea, the temperature and humidity near the crack of the pipe need to be measured to detect the leakage fields. As the fluids with high pressure and high temperature flow in the pipe system in an actual nuclear power plant, the pipe leakage experiment was performed in the high pressure and high temperature condition. When the fluids with high temperature and pressure leak in the crack, the water will evaporate quickly, which means this process belongs to spray flash evaporation process. The temperature and humidity variations were monitored in the experiment with temperature and humidity probes which have the advantage of responding to the change of temperature and humidity sensitively. The data collection program was mainly written based on the LABVIEW platform. The collecting time step was set 1s. As the measuring position and leakage flux are two key factors for the pipe leakage, the experiment was carried out with different measuring positions and leakage fluxes conditions. The experimental results showed that the leak flux had an important influence on the temperature and humidity near the pipe crack. The temperature and humidity started to change in a very short time with large leak flux. At the same time, the velocity of the temperature and humidity change was high with large leak flux. When the pipe leakage occurred in the location near the temperature and humidity probe, the temperature and humidity responded quickly and the velocity of temperature and humidity change was large. The experiment data can be used for the prediction of the pipe leakage in the nuclear power plants.

2019 ◽  
Vol 6 (1) ◽  
Author(s):  
Benan Cai ◽  
Qi Zhang ◽  
Yu Weng ◽  
Hongfang Gu ◽  
Haijun Wang

Abstract Pipelines such as the surge line and main pipe are easily subjected to thermal stratification and thermal fatigue as a result of the nonuniform temperature distribution in the nuclear power plants. When the surge line or main pipe subjected to thermal stratification and thermal fatigue keeps operating for long time, the pipe leakage may happen due to the existence of pipeline crack. When the fluids with high temperature and pressure leak in the crack, the water will evaporate quickly, which means this process belongs to spray flash evaporation process. The flash evaporation related to pipe leak was experimentally studied in the paper. The experiment was carried out under high temperature and high pressure with low spray rate. The temperature and relative humidity (T&H) variations over time were monitored in the experiment with installing T&H detectors. The T&H variations at different measurement positions and with different spray rates were analyzed, respectively. In addition, the effect of the dimensionless parameters including the Weber number and Jakob number was also investigated. Results indicated that the response speed increased with the increase of the spray flow rate. Higher Weber number and higher Jakob number led to higher evaporation rate. The slight pipe leakage can be predicted by using the (T&H) in the hazardous areas.


ANRI ◽  
2020 ◽  
pp. 31-44
Author(s):  
Aleksey Ekidin ◽  
Aleksey Vasil'ev ◽  
Maksim Vasyanovich ◽  
Evgeniy Nazarov ◽  
Mariya Pyshkina ◽  
...  

The article presents the results of field studies in the area of the Belarusian NPP in the pre-operational period. The «background» contents of gamma-emitting radionuclides in individual components of the environment are determined. The main array of dose rate measurements in the area of the NPP construction site is in the range 0.048 ÷ 0.089 μSv/h. External radiation in the surveyed area is formed at 96% due to 40K, 226Ra and 232Th. The information obtained can be used to correctly interpret the data of future radiation monitoring during normal operation of nuclear power plants.


2020 ◽  
Vol 7 (1) ◽  
Author(s):  
Arnold Gad-Briggs ◽  
Emmanuel Osigwe ◽  
Pericles Pilidis ◽  
Theoklis Nikolaidis ◽  
Suresh Sampath ◽  
...  

Abstract Numerous studies are on-going on to understand the performance of generation IV (Gen IV) nuclear power plants (NPPs). The objective is to determine optimum operating conditions for efficiency and economic reasons in line with the goals of Gen IV. For Gen IV concepts such as the gas-cooled fast reactors (GFRs) and very-high temperature reactors (VHTRs), the choice of cycle configuration is influenced by component choices, the component configuration and the choice of coolant. The purpose of this paper to present and review current cycles being considered—the simple cycle recuperated (SCR) and the intercooled cycle recuperated (ICR). For both cycles, helium is considered as the coolant in a closed Brayton gas turbine configuration. Comparisons are made for design point (DP) and off-design point (ODP) analyses to emphasize the pros and cons of each cycle. This paper also discusses potential future trends, include higher reactor core outlet temperatures (COT) in excess of 1000 °C and the simplified cycle configurations.


2019 ◽  
Vol 61 (3) ◽  
pp. 352-364 ◽  
Author(s):  
A. A. Ekidin ◽  
K. L. Antonov ◽  
M. E. Vasyanovich ◽  
I. A. Kapustin ◽  
I. Yu. Filatov

1976 ◽  
Vol 41 (6) ◽  
pp. 1076-1078
Author(s):  
A. I. El'tsov ◽  
A. K. Zabavin ◽  
Yu. A. Kotel'nikov ◽  
A. A. Labut ◽  
E. P. Larin ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document