MEMS Pressure Sensor Array for Aeroacoustic Analysis of the Turbulent Boundary Layer

Author(s):  
Joshua S. Krause ◽  
Robert D. White ◽  
Mark J. Moeller ◽  
Judith M. Gallman ◽  
Richard De Jong

The design, fabrication, and characterization of a surface micromachined, front-vented, 64 channel (8×8), capacitively sensed pressure sensor array is described. The array was fabricated using the MEMSCAP PolyMUMPs® process, a three layer polysilicon surface micromachining process. An acoustic lumped element circuit model was used to design the system. The results of our computations for the design, including mechanical components, environmental loading, fluid damping, and other acoustic elements are detailed. Theory predicts single element sensitivity of 1 mV/Pa at the gain stage output in the 400–40,000 Hz band. A laser Doppler velocimetry (LDV) system has been used to map the spatial motion of the elements in response to electrostatic excitation. A strong resonance appears at 480 kHz for electrostatic excitation, in good agreement with mathematical models. Static stiffness measured electrostatically using an interferometer is 0.1 nm/V2, similar to the expected stiffness. Preliminary acoustic sensitivity studies show single element acoustic sensitivity (as a function of frequency) increasing from 0.01 mV/Pa at 200 Hz to 0.16 mV/Pa at 2 kHz. A more in depth analysis of acoustic sensitivity is ongoing.

2022 ◽  
Author(s):  
Senthilkumar Subramanian ◽  
Rory Hampson ◽  
Dayi Zhang ◽  
Konstantinos Kontis ◽  
Gordon Dobie ◽  
...  

Author(s):  
L. T. Germinario

Understanding the role of metal cluster composition in determining catalytic selectivity and activity is of major interest in heterogeneous catalysis. The electron microscope is well established as a powerful tool for ultrastructural and compositional characterization of support and catalyst. Because the spatial resolution of x-ray microanalysis is defined by the smallest beam diameter into which the required number of electrons can be focused, the dedicated STEM with FEG is the instrument of choice. The main sources of errors in energy dispersive x-ray analysis (EDS) are: (1) beam-induced changes in specimen composition, (2) specimen drift, (3) instrumental factors which produce background radiation, and (4) basic statistical limitations which result in the detection of a finite number of x-ray photons. Digital beam techniques have been described for supported single-element metal clusters with spatial resolutions of about 10 nm. However, the detection of spurious characteristic x-rays away from catalyst particles produced images requiring several image processing steps.


2020 ◽  
Vol 8 (4) ◽  
pp. 296-307
Author(s):  
Konstantin Krestovnikov ◽  
Aleksei Erashov ◽  
Аleksandr Bykov

This paper presents development of pressure sensor array with capacitance-type unit sensors, with scalable number of cells. Different assemblies of unit pressure sensors and their arrays were considered, their characteristics and fabrication methods were investigated. The structure of primary pressure transducer (PPT) array was presented; its operating principle of array was illustrated, calculated reference ratios were derived. The interface circuit, allowing to transform the changes in the primary transducer capacitance into voltage level variations, was proposed. A prototype sensor was implemented; the dependency of output signal power from the applied force was empirically obtained. In the range under 30 N it exhibited a linear pattern. The sensitivity of the array cells to the applied pressure is in the range 134.56..160.35. The measured drift of the output signals from the array cells after 10,000 loading cycles was 1.39%. For developed prototype of the pressure sensor array, based on the experimental data, the average signal-to-noise ratio over the cells was calculated, and equaled 63.47 dB. The proposed prototype was fabricated of easily available materials. It is relatively inexpensive and requires no fine-tuning of each individual cell. Capacitance-type operation type, compared to piezoresistive one, ensures greater stability of the output signal. The scalability and adjustability of cell parameters are achieved with layered sensor structure. The pressure sensor array, presented in this paper, can be utilized in various robotic systems.


2019 ◽  
Vol 19 (15) ◽  
pp. 6076-6084 ◽  
Author(s):  
Md. Omar Faruk Emon ◽  
Jeongwoo Lee ◽  
U Hyeok Choi ◽  
Da-Hye Kim ◽  
Kyung-Chang Lee ◽  
...  

2021 ◽  
Author(s):  
Hang Xue ◽  
Zhirong Lin ◽  
Wenbing Jiang ◽  
Zhengqi Niu ◽  
Kuang Liu ◽  
...  

2021 ◽  
Author(s):  
Juzhong Zhang ◽  
Yuyi Chu ◽  
Zhisen Wang ◽  
Tingfeng Ye ◽  
Liming Cai ◽  
...  

Sign in / Sign up