Seismic Responses of a Building Isolated With Multiple Friction Pendulum System Subjected to Multi-Directional Excitations

Author(s):  
C. S. Tsai ◽  
Yung-Chang Lin ◽  
H. C. Su

In order to prevent a building from earthquake damage, a base isolation system called the multiple friction pendulum system (MFPS) which has numerous concave sliding interfaces is proposed to isolate a building from its foundation. Mathematical formulations have been derived to simulate the characteristic of the MFPS isolation system subjected to multi-directional excitations. By virtue of the derived mathematical formulations, the phenomena of the sliding motions of the MFPS isolator with several concave sliding interfaces under multi-directional earthquakes can be clearly understood. Also, numerical analyses of a building isolated with the MFPS isolator with several sliding interfaces have been conducted in this study to evaluate the efficiency of the proposed system in seismic mitigation. It has been proved through numerical analyses that structural responses have been reduced significantly and that the proposed system is a good tool to insure the safety of structures during earthquakes.

Author(s):  
C. S. Tsai ◽  
Jeng-Wen Lin ◽  
Yung-Chang Lin ◽  
Chia-Chi Chen

In order to promote seismic resistance capability of structures and simplify the manufacturing processes of an isolator, a new base isolation system called the multiple trench friction pendulum system (MTFPS) is proposed. The investigations for the proposed isolator have been carried out to address its mechanical characteristics and to assess its performance in seismic mitigation through a series of shaking table tests in this study. The MTFPS isolator can provide different natural periods, displacement capacities and damping effects in any two independent directions. The natural period and damping effect for a MTFPS isolator change continually during earthquakes. Results from the shaking table tests on a scaled three-story structure isolated with MTFPS isolators illustrate that the proposed MTFPS isolator can isolate most earthquake induced energy and provide good protection for structures from earthquake damage. In addition, the mathematical formulations for the MTFPS isolator have also been derived to examine its characteristics.


Author(s):  
C. S. Tsai ◽  
Yung-Chang Lin ◽  
H.-C. Su

In order to systematically investigate the mechanical characteristic of a multiple friction pendulum system with more than two concave sliding interfaces and one articulated slider located between these concave sliding interfaces, on the basis of the plasticity theory, a plasticity model called the multiple yield and bounding surfaces model is proposed in addition to analytical formulations derived from the proposed concept of subsystems in this study. The proposed model has two separate groups of multiple yield and bounding surfaces. The first group is adopted to describe the mechanical behavior of the subsystem including the concave sliding interfaces above the articulated slider and the second group is used for modeling the sliding characteristic of the subsystem representing the concave sliding interfaces below the articulated slider. The connection of these two subsystems in series forms the mechanical characteristic of the entire MFPS isolation system. By virtue of the proposed model, the phenomena of the sliding motions of the MFPS isolator with multiple concave sliding interfaces under cyclical loadings can be clearly understood. Analytical results infer that the natural frequency and damping effect of the MFPS isolator with multiple concave sliding interfaces change continually during earthquakes and are controllable through appropriate designs.


Author(s):  
C. S. Tsai ◽  
Yung-Chang Lin ◽  
Wen-Shin Chen

Seismic mitigation of high-tech facilities is a very important issue in earthquake prone areas such as Taiwan, Japan, U.S.A., etc. In order to lessen vulnerability of earthquake damage of high-tech equipment, base isolation seems to be a good choice. This paper mainly explores the possibility of using a new base isolation system named the trench friction pendulum system (TFPS) to reduce seismic responses of high-tech facilities. The main reasons, from a engineer’s point of view, to use this system for protecting high-tech equipment from earthquake damage are high efficiency and low cost. A series of shaking table tests for a high-tech facility isolated with TFPS isolators were carried out in the Department of Civil Engineering, Feng Chia University, Taichung, Taiwan, ROC. The experimental results show that the proposed system provides a good protection for the high-tech facility during strong earthquakes.


Author(s):  
C. S. Tsai ◽  
C. I. Hsueh ◽  
H. C. Su

This paper is aimed at the performance evaluation of the multiple direction-optimized friction pendulum system (MDO-FPS) with multiple sliding interfaces on seismic mitigation through a series of shaking table tests of a full scale building isolated with MDO-FPS isolators. Experimental tests of a three-story steel building of 40 tons in total weight, 3m and 4.5m in length and width, respectively, in two horizontal directions and 9m in height, subjected to various types of earthquakes were carried out to investigate the efficiency of the isolators in reducing structural responses during earthquakes. Results obtained from the shaking table tests demonstrate that the roof accelerations, base shears, column shear forces have been remarkably reduced while compared to the responses of a traditionally designed structure.


Author(s):  
C. S. Tsai ◽  
Yung-Chang Lin ◽  
H. C. Su ◽  
Ya-Fang Tseng

The multiple trench friction pendulum system (MTFPS) which has numerous sliding interfaces in each of two perpendicular directions can provide different natural periods, displacement capacities and damping effects at various levels of displacements in the individual direction. In order to characterize the mechanical behavior of the MTFPS isolator under multi-directional earthquakes, a plasticity model named as the multiple yield and bounding surfaces model is proposed in this study. Investigations for buildings isolated with TFPS isolators and subjected to multi-directional excitations have been carried out to assess the performance of the MTFPS isolation bearing in seismic mitigation through numerical analyses. Results from numerical analyses illustrate that the MTFPS isolation bearing can isolate most earthquake induced energy and provide good protection for structures from earthquake damage.


2012 ◽  
Vol 134 (2) ◽  
Author(s):  
C. S. Tsai ◽  
H. C. Su ◽  
Yung-Chang Lin

In this paper, a base isolator called a multiple direction optimized-friction pendulum system (Multiple DO-FPS) with numerous sliding interfaces is proposed. To understand the mechanical behavior of the Multiple DO-FPS isolator under multidirectional excitations, an analytical model called the multiple yield and bounding surfaces model is proposed. On the basis of the derived mathematical formulations for simulation of the characteristics of the Multiple DO-FPS isolation bearing, it is revealed that the natural period and damping effect of the Multiple DO-FPS isolator are a function of the sliding displacement and sliding direction. By virtue of the proposed model, the phenomena of the sliding motions of the Multiple DO-FPS isolator with numerous sliding interfaces subjected to multidirectional excitations can be understood in a simple manner. The analytical results indicate that the natural frequency and damping effect of the Multiple DO-FPS isolator with numerous concave sliding interfaces change continually during earthquakes and are controllable through appropriate designs.


Author(s):  
C. S. Tsai ◽  
Yung-Chang Lin ◽  
H.-C. Su

In this paper, a base isolator call the multiple direction optimized-friction pendulum system (Multiple DO-FPS) with numerous sliding interfaces is proposed. For understanding the mechanical behavior of the Multiple DO-PFS isolator under multi-directional excitations, an analytical model called the multiple yield and bounding surfaces model is also proposed. On the basis of the derived mathematical formulations for the simulation of the characteristic of the Multiple DO-FPS isolation bearing, it is revealed that the natural period and damping effect for a Multiple DO-FPS is a function of the sliding displacement and sliding direction. By virtue of the proposed model, the phenomena of the sliding motions of the Multiple DO-FPS isolator with numerous sliding interfaces subjected to multi-directional excitations can be simply understood. Analytical results infer that the natural frequency and damping effect of the Multiple DO-PFS isolator with numerous concave sliding interfaces change continually during earthquakes and are controllable through appropriate designs.


2014 ◽  
Vol 578-579 ◽  
pp. 1361-1365
Author(s):  
Lin Liu ◽  
Xuan Min Li ◽  
Wei Tian

Friction Pendulum Systems have been used as base isolation systems for both new construction and retrofit around the world. This paper presented its implementation in an office building located in Shanghai. To evaluate its impact on seismic performance of the retrofitted structure, models are needed to capture the intricate nonlinear behavior of both structural components and isolator elements. Nonlinear time history analysis of the building for the original and retrofitted cases was conducted to assess the efficiency of the isolation system at the high earthquake level. The numerical results indicate that the retrofitted structure experiences significantly less damage and less deformation due to the shake isolation and energy dissipation through the isolators.


Author(s):  
C. S. Tsai ◽  
Ching-Pei Tsou ◽  
Yung-Chang Lin ◽  
Mei-Ju Chen ◽  
Wen-Shin Chen

Earthquake ground motions often result in significant seismic disasters. Strong ground motions will not only cause damage, but may also cause the collapse of structures. People have to face up the suffering from the earthquake damage, and the indirect loss which may be more serious than the damage itself. For example, the antique breaks in museum, and the equipment damages in hi-tech industries are often in huge loss. Therefore, in addition to promoting the earthquake-resistant capacity of a structure, it is also important to ensure the safety of the ancient valuable objects and the instruments in structures. For this reason, this study is aimed at a new damped rolling type base isolation system named the ball pendulum system (BPS) to be installed under the motion sensitive equipment and proceeding all related studies. The isolation device can isolate earthquake from buildings or equipments in any direction by rolling motions and damping materials. This study has conducted a series of component tests and shaking table tests for examining the behaviors of materials and earthquake proof benefits. From the experiment results, it is found that this device can reduce more than 80% of acceleration response under earthquakes with peak ground acceleration of 450 gal. So, the new rolling isolation system with a damping material can be recognized as a feasible and promising way in mitigating the seismic response of equipment.


Sign in / Sign up

Export Citation Format

Share Document