scholarly journals Motion effects on the measurement of stiffness on ultrasound shear wave elastography: a moving liver fibrosis phantom study

2018 ◽  
Vol 1 (1) ◽  
pp. 14 ◽  
Author(s):  
Hyun Joo Shin ◽  
Myung-Joon Kim ◽  
Choon-Sik Yoon ◽  
Kwanseop Lee ◽  
Kwan Sik Lee ◽  
...  

Aims: To evaluate the differences between shear wave velocities (SWVs) measured with ultrasound elastography during the continuous motion using liver fibrosis phantoms.Materials and methods: Elasticities were measured with convex and linear transducers of supersonic shear wave imaging (SSI) and acoustic radiation force impulse imaging (ARFI) using liver elasticity phantoms (3.0 and 16.9 kPa) at depths of 2, 3, 4, and 5 cm. Motion velocities were 30 and 60 rpm with the phantoms in an upright position on the Orbital shaker. To simulate different directional motion, the phantoms were laid on their side on the shaker. The values between moving and static status were compared, and the number of measurement failure was counted. Results: In SSI, the convex transducer was less affected by motion at 30 rpm with the 3 kPa phantom. In the higher velocity motion and in the higher stiffness phantom, most values from SSI were different comparing with static status, and there was a tendency for elasticity values to increase during movement. In ARFI, there were frequent measurement failures without stable results during the motion.Conclusions: Motion affected the measurement of elasticity differently in SSI and ARFI, according to the velocity, direction of the motion, and phantom stiffness. The convex transducer of SSI was less affected by motion in lower velocity motion and when using normal liver stiffness phantom.

2021 ◽  
pp. 1-3
Author(s):  
Sunil Patel ◽  
Chinmay Kulkarni ◽  
Srikanth Moorthy

Aim To prospectively determine the sensitivity, specificity and accuracy of point shear wave elastography as a non-invasive method in the diagnosis of clinically significant hepatic fibrosis with various etiologies of liver using liver biopsy as gold standard.To determine the stiffness cut-off values for point shear wave elastography (pSWE) diagnosis of clinically significant hepatic fibrosis. Methods Fifty patients with elevated liver enzymes were examined by point shear wave Elastography and they subsequently underwent percutaneous liver biopsy. Ultrasound Elastography findings were correlated with the histopathology fibrosis staging (METAVIR / Brunt Scoring) Results Liver stiffness value of >7.6 kPa was cut-off for clinically significant fibrosis and had a sensitivity of 92%, a specificity of 78.3% and an accuracy of 86%. Conclusions ElastPQ is a non-invasive and sensitive technique for determining the clinically significant liver fibrosis in patients with various etiologies.


2016 ◽  
Vol 25 (4) ◽  
pp. 525-532 ◽  
Author(s):  
Monica Lupșor-Platon ◽  
Radu Badea ◽  
Mirela Gersak ◽  
Anca Maniu ◽  
Ioana Rusu ◽  
...  

There has been great interest in the development of non-invasive techniques for the diagnosis of liver fibrosis in chronic liver diseases, including ultrasound elastographic methods. Some of these methods have already been adequately studied for the non-invasive assessment of diffuse liver diseases. Others, however, such as two-dimensional Shear Wave Elastography (SWE), of more recent appearance, have yet to be validated and some aspects are for the moment incompletely elucidated. This review discusses some of the aspects related to two-dimensional SWE: the examination technique, the examination performance indicators, intra and interobserver agreement and clinical applications. Recommendations for a high-quality examination technique are formulated. Key words:  –  –  – Two-dimensional Shear Wave Elastography. Abbreviations: 2D- SWE: Two-dimensional Shear Wave Elastography; 3D- SWE: Three-dimensional Shear Wave Elastography; AUROC: area under the receiver operating characteristic curves; ARFI Acoustic Radiation Force Impulse Elastography; EFSUMB: European Federation of Societies for Ultrasound in Medicine and Biology; HVPG: hepatic venous pressure gradient; LS: liver stiffness; LR: likelihood ratio; NPV: negative predictive value; PPV: positive predictive value; ROI: region of interest; RT-E: Real Time-Elastography; Se: sensitivity; Sp: specificity; TE: Transient Elastography; US: ultrasound; VM: valid measurement; E: Young’s modulus


2018 ◽  
Vol 49 (1) ◽  
pp. 91-98 ◽  
Author(s):  
Paraskevi Galina ◽  
Efthymia Alexopoulou ◽  
Aglaia Zellos ◽  
Virginia Grigoraki ◽  
Tania Siahanidou ◽  
...  