The MEL-X project at the Lawrence Livermore National Laboratory: a mirror-based delay line for x-rays

Author(s):  
Tom Pardini ◽  
Randy Hill ◽  
Todd Decker ◽  
Jennifer Alameda ◽  
Regina Soufli ◽  
...  
2011 ◽  
Vol 89 (5) ◽  
pp. 647-651 ◽  
Author(s):  
C. Zulick ◽  
F. Dollar ◽  
H. Chen ◽  
K. Falk ◽  
G. Gregori ◽  
...  

The production of X-rays from electron transitions into K-shell vacancies (Kα,β) emission) is a well-known process in atomic physics and has been extensively studied as a plasma diagnostic in low- and mid-Z materials. However, X-ray spectra from near neutral high-Z ions are very complex, and their interpretation requires the use of state-of-the-art atomic calculations. In this experiment, the Titan laser system at Lawrence Livermore National Laboratory was used to deliver an approximately 350 J laser pulse, with a 10 ps duration and a wavelength of 1054 nm, to a gold (Au) target. A transparent bent quartz crystal spectrometer with a hard X-ray energy window, ranging from 17 to 102 keV, was used to measure the emission spectrum. Kα1,α2 and Kβ1,γ1 transitions were observed over a range of target sizes. Additionally, a series of shots were conducted with a pre-ionizing long pulse (3 ns, 1–10 J, 527 nm) on the backside of the target. FLYCHK, an atomic non-LTE code, designed to provide ionization and population distributions, was used to model the experiment. Kα/Kβ ratios were found to be in good agreement with the predicted value for room temperature Au targets.


2004 ◽  
Vol 22 (3) ◽  
pp. 221-244 ◽  
Author(s):  
F.V. HARTEMANN ◽  
A.M. TREMAINE ◽  
S.G. ANDERSON ◽  
C.P.J. BARTY ◽  
S.M. BETTS ◽  
...  

The Compton scattering of a terawatt-class, femtosecond laser pulse by a high-brightness, relativistic electron beam has been demonstrated as a viable approach toward compact, tunable sources of bright, femtosecond, hard X-ray flashes. The main focus of this article is a detailed description of such a novel X-ray source, namely the PLEIADES (Picosecond Laser–Electron Inter-Action for the Dynamical Evaluation of Structures) facility at Lawrence Livermore National Laboratory. PLEIADES has produced first light at 70 keV, thus enabling critical applications, such as advanced backlighting for the National Ignition Facility andin situtime-resolved studies of high-Zmaterials. To date, the electron beam has been focused down to σx= σy= 27 μm rms, at 57 MeV, with 266 pC of charge, a relative energy spread of 0.2%, a normalized horizontal emittance of 3.5 mm·mrad, a normalized vertical emittance of 11 mm·mrad, and a duration of 3 ps rms. The compressed laser pulse energy at focus is 480 mJ, the pulse duration 54 fs Intensity Full Width at Half-Maximum (IFWHM), and the 1/e2radius 36 μm. Initial X rays produced by head-on collisions between the laser and electron beams at a repetition rate of 10 Hz were captured with a cooled CCD using a CsI scintillator; the peak photon energy was approximately 78 keV, and the observed angular distribution was found to agree very well with three-dimensional codes. The current X-ray dose is 3 × 106photons per pulse, and the inferred peak brightness exceeds 1015photons/(mm2× mrad2× s × 0.1% bandwidth). Spectral measurements using calibrated foils of variable thickness are consistent with theory. Measurements of the X-ray dose as a function of the delay between the laser and electron beams show a 24-ps full width at half maximum (FWHM) window, as predicted by theory, in contrast with a measured timing jitter of 1.2 ps, which contributes to the stability of the source. In addition,K-edge radiographs of a Ta foil obtained at different electron beam energies clearly demonstrate the γ2-tunability of the source and show very good agreement with the theoretical divergence-angle dependence of the X-ray spectrum. Finally, electron bunch shortening experiments using velocity compression have also been performed and durations as short as 300 fs rms have been observed using coherent transition radiation; the corresponding inferred peak X-ray flux approaches 1019photons/s.


Author(s):  
Bálint Joó ◽  
Mike A. Clark

The QUDA library for optimized lattice quantum chromodynamics using GPUs, combined with a high-level application framework such as the Chroma software system, provides a powerful tool for computing quark propagators, a key step in current calculations of hadron spectroscopy, nuclear structure, and nuclear forces. In this contribution we discuss our experiences, including performance and strong scaling of the QUDA library and Chroma on the Edge Cluster at Lawrence Livermore National Laboratory and on various clusters at Jefferson Lab. We highlight some scientific successes and consider future directions for graphics processing units in lattice quantum chromodynamics calculations.


1992 ◽  
Vol 4 (7) ◽  
pp. 2326-2337 ◽  
Author(s):  
B. J. MacGowan ◽  
L. B. Da Silva ◽  
D. J. Fields ◽  
C. J. Keane ◽  
J. A. Koch ◽  
...  

Author(s):  
Matthew R. Feldman

Based on a recommendation from the Defense Nuclear Facilities Safety Board, the Department of Energy (DOE) Office of Nuclear Safety Policy and Assistance (HS-21) has recently issued DOE Manual 441.1-1 entitled Nuclear Material Packaging Manual. This manual provides guidance regarding the use of non-engineered storage media for all special nuclear material throughout the DOE complex. As part of this development effort, HS-21 has funded the Oak Ridge National Laboratory (ORNL) Transportation Technologies Group (TTG) to develop and demonstrate testing protocols for such onsite containers. ORNL TTG to date has performed preliminary tests of representative onsite containers from Lawrence Livermore National Laboratory and Los Alamos National Laboratory. This paper will describe the testing processes that have been developed.


Sign in / Sign up

Export Citation Format

Share Document