Flat optics for broad-band large angle-of-view hologram and sub-diffraction limit imaging

Author(s):  
Jinghua Teng
2020 ◽  
Vol 2020 ◽  
pp. 1-9
Author(s):  
Pei-Jung Wu ◽  
Chih-Hao Chuang ◽  
Chien-Yu Chen ◽  
Jeng-Han Wu ◽  
Bor-Shyh Lin

This study proposes to apply the combination of two 90-degree prisms and a holographic optical element to an image-dividing element, divide an image into three through the virtual image projection system, and accurately project the images to 160 cm behind the windshield. In order to distinguish the left image, middle image, and right image at the horizontal direction, the 90-degree prism is first utilized for horizontally deflecting the light, a holographic optical element is then used for presenting the vertical deflection of the image, and finally, the images are horizontally arranged as a real image on the diffuser. An image-dividing element is eventually integrated to the virtual image projection system. Then, the divided images are made as a virtual image which is projected to 160 cm behind the windshield to combine with the street scene. The horizontal angle of view of an eyebox is increased from 2.51° to 7.22°, and the size of the eyebox is 31.68 cm × 12.48 cm, allowing a wide-view laser-based head-up display with the large-angle beam-splitting function being successfully designed. It would not affect the field of view on the road, and this system could reduce the space and be arranged easily in a vehicle. Therefore, this proposed system is suitable for the aftermarket.


Author(s):  
Pan-Dong Fan ◽  
Qiang Miao ◽  
Ping Yang ◽  
Quayle Chen ◽  
Tom Xue ◽  
...  

In recent years, the application of Flexible Display (FD) is increasing dramatically due to its high brightness, high contrast, and large angle of view. Also because the substrate polymer material is flexible, FD is easily and widely used in various electronic packages. The competition of products based on these technologies such as electronic paper and mobile screen can be improved. In most of these applications, failure of FD can directly lead to failure of device. However, reliability data on FD are not commonly available in published literature, and the reliability of FD in practical application has not been studied very well. This paper presents an experimental study of FD with focus on its reliability under varying temperature and humidity conditions. The purpose of this paper is to investigate the failure mode of FD based on environmental test including steady damp heat test, dry heat test, cyclic damp heat test and cold test. The failure modes are discussed and the analysis is presented. In this study, all tests are conducted with visual inspections during each test procedure.


Lab on a Chip ◽  
2014 ◽  
Vol 14 (18) ◽  
pp. 3594-3602 ◽  
Author(s):  
Kang Wei ◽  
Hansong Zeng ◽  
Yi Zhao

An optofluidic device named the “Insect–Human Hybrid Eye” (IHHE), which combines the architectural merits of both human camera eyes and insect compound eyes, is presented to implement imaging with a large angle of view and adaptive focusing along any direction within the field.


2017 ◽  
Vol 11 (3) ◽  
pp. 1700025 ◽  
Author(s):  
Kun Huang ◽  
Hong Liu ◽  
Guangyuan Si ◽  
Qian Wang ◽  
Jiao Lin ◽  
...  
Keyword(s):  

2017 ◽  
Vol 25 (25) ◽  
pp. 31174 ◽  
Author(s):  
Farzaneh Abolmaali ◽  
Aaron Brettin ◽  
Andrew Green ◽  
Nicholaos I. Limberopoulos ◽  
Augustine M. Urbas ◽  
...  

Author(s):  
Burton B. Silver ◽  
Theodore Lawwill

Dutch-belted 1 to 2.5 kg anesthetized rabbits were exposed to either xenon or argon laser light administered in a broad band, designed to cover large areas of the retina. For laser exposure, the pupil was dilated with atropine sulfate 1% and pheny lephrine 10%. All of the laser generated power was within a band centered at 5145.0 Anstroms. Established threshold for 4 hour exposures to laser irradiation are in the order of 25-35 microwatts/cm2. Animals examined for ultrastructural changes received 4 hour threshold doses. These animals exhibited ERG, opthalmascopic, and histological changes consistent with threshold damage.One month following exposure the rabbits were killed with pentobarbitol. The eyes were immediately enucleated and dissected while bathed in 3% phosphate buffered gluteraldehyde.


Author(s):  
Eckhard Quandt ◽  
Stephan laBarré ◽  
Andreas Hartmann ◽  
Heinz Niedrig

Due to the development of semiconductor detectors with high spatial resolution -- e.g. charge coupled devices (CCDs) or photodiode arrays (PDAs) -- the parallel detection of electron energy loss spectra (EELS) has become an important alternative to serial registration. Using parallel detection for recording of energy spectroscopic large angle convergent beam patterns (LACBPs) special selected scattering vectors and small detection apertures lead to very low intensities. Therefore the very sensitive direct irradiation of a cooled linear PDA instead of the common combination of scintillator, fibre optic, and semiconductor has been investigated. In order to obtain a sufficient energy resolution the spectra are optionally magnified by a quadrupole-lens system.The detector used is a Hamamatsu S2304-512Q linear PDA with 512 diodes and removed quartz-glas window. The sensor size is 13 μm ∗ 2.5 mm with an element spacing of 25 μm. Along with the dispersion of 3.5 μm/eV at 40 keV the maximum energy resolution is limited to about 7 eV, so that a magnification system should be attached for experiments requiring a better resolution.


Sign in / Sign up

Export Citation Format

Share Document