Optical transfer matrix: matrix correlation as frequency domain analysis of polarization imaging system

2021 ◽  
Author(s):  
Wei Wang ◽  
Mitsuo Takeda
1999 ◽  
Author(s):  
Zongxia Jiao ◽  
Qing Hua ◽  
Kai Yu

Abstract In the analysis of liquid-filled piping systems there are Poisson-coupled axial stress waves in the pipe and liquid column, which are caused by the dilation of the pipe. In some conditions the influence of viscous friction that is usually frequency-dependent should not be omitted, which in fact is another kind of coupled form. It directly influences the amplitude of vibration of piping systems to some degree. The larger the viscosity of the liquid is, the greater the influence will be. Budny (1991) included the viscous friction influence in time domain analysis of fluid-structure interaction, but did not give frequency domain analysis. Lesmez (1990) gave the model analysis liquid-filled piping systems without considering friction. If the friction is not included in frequency domain analysis, the vibration amplitude will be greater than that when friction is included, especially at harmony points, cause large errors in the simulation of fluid pipe network analysis, although it may have little influence on the frequency of harmony points. The present paper will give detail solutions to the transfer matrix that represents the motion of single pipe section, which is the basis of complex fluid-structure interaction analysis. Combined with point matrices that describe specified boundary conditions, overall transfer matrix for a piping system can be assembled. Corresponding state vectors can then be evaluated to predict the piping and liquid motion. At last, a twice-coordinate transformation method is adopted in joint coupling. Consequently, the vibration analysis of spatial liquid-filled piping systems can be carried out. It is proved to be succinct, valid and versatile. This method can be extended to the simulation of the curved spatial pipeline systems.


2021 ◽  
Vol 143 ◽  
pp. 107297
Author(s):  
Ziyang Zhang ◽  
Song Ye ◽  
Sunchen Wang ◽  
Shu Li ◽  
Yuting Zhang ◽  
...  

Energies ◽  
2021 ◽  
Vol 14 (12) ◽  
pp. 3606
Author(s):  
Jing-Yuan Lin ◽  
Chuan-Ting Chen ◽  
Kuan-Hung Chen ◽  
Yi-Feng Lin

Three-phase wye–delta LLC topology is suitable for voltage step down and high output current, and has been used in the industry for some time, e.g., for server power and EV charger. However, no comprehensive circuit analysis has been performed for three-phase wye–delta LLC. This paper provides complete analysis methods for three-phase wye–delta LLC. The analysis methods include circuit operation, time domain analysis, frequency domain analysis, and state–plane analysis. Circuit operation helps determine the circuit composition and operation sequence. Time domain analysis helps understand the detail operation, equivalent circuit model, and circuit equation. Frequency domain analysis helps obtain the curve of the transfer function and assists in circuit design. State–plane analysis is used for optimal trajectory control (OTC). These analyses not only can calculate the voltage/current stress, but can also help design three-phase wye-delta connected LLC and provide the OTC control reference. In addition, this paper uses PSIM simulation to verify the correctness of analysis. At the end, a 5-kW three-phase wye–delta LLC prototype is realized. The specification of the prototype is a DC input voltage of 380 V and output voltage/current of 48 V/105 A. The peak efficiency is 96.57%.


Sign in / Sign up

Export Citation Format

Share Document