Radiation absorbed dose distribution in a patient treated with yttrium-90 microspheres for hepatocellular carcinoma

2004 ◽  
Vol 31 (9) ◽  
pp. 2449-2453 ◽  
Author(s):  
Mehrdad Sarfaraz ◽  
Andrew S. Kennedy ◽  
Martin A. Lodge ◽  
X. Allen Li ◽  
Xingen Wu ◽  
...  
2020 ◽  
Vol 80 ◽  
pp. 317-326
Author(s):  
Julia Brosch ◽  
Astrid Gosewisch ◽  
Lena Kaiser ◽  
Max Seidensticker ◽  
Jens Ricke ◽  
...  

1994 ◽  
Vol 33 (05) ◽  
pp. 206-214 ◽  
Author(s):  
J. Triller ◽  
H. U. Baer ◽  
Livia Geiger ◽  
H. F. Beer ◽  
C. Becker ◽  
...  

SummaryTwenty patients with unresectable hepatocellular carcinoma (HCC) were followed up to 5 years after transarterial radiotherapy with 90Y-resin particles. Diagnostic radioembolizations of 99mTc-macroaggregates facilitated scintigraphic assessment of activity distribution, dose evaluation and final procedural verification. The overall survival rates were 56, 38 and 14% (after 1, 2 and 3 years, resp.). Patients with unifocal HCC and a single feeding artery (n = 7) even presented 83, 67 and 40% (2 alive after 2.75 and 4 years). With multiple arteries (n = 7), the longest survival was 26 months. Patients with multifocal HCC survived up to 33 months after selective radioembolization. Quality of life was improved in all. Survival was positively correlated with absorbed dose but residual/recurrent tumour occurred even after ≥300 Gy. Post-treatment symptoms were minimal (35 applications), pulmonary shunt rates were correctly predicted and pulmonary complications avoided.


Author(s):  
Hugo Levillain ◽  
Oreste Bagni ◽  
Christophe M. Deroose ◽  
Arnaud Dieudonné ◽  
Silvano Gnesin ◽  
...  

Abstract Purpose A multidisciplinary expert panel convened to formulate state-of-the-art recommendations for optimisation of selective internal radiation therapy (SIRT) with yttrium-90 (90Y)-resin microspheres. Methods A steering committee of 23 international experts representing all participating specialties formulated recommendations for SIRT with 90Y-resin microspheres activity prescription and post-treatment dosimetry, based on literature searches and the responses to a 61-question survey that was completed by 43 leading experts (including the steering committee members). The survey was validated by the steering committee and completed anonymously. In a face-to-face meeting, the results of the survey were presented and discussed. Recommendations were derived and level of agreement defined (strong agreement ≥ 80%, moderate agreement 50%–79%, no agreement ≤ 49%). Results Forty-seven recommendations were established, including guidance such as a multidisciplinary team should define treatment strategy and therapeutic intent (strong agreement); 3D imaging with CT and an angiography with cone-beam-CT, if available, and 99mTc-MAA SPECT/CT are recommended for extrahepatic/intrahepatic deposition assessment, treatment field definition and calculation of the 90Y-resin microspheres activity needed (moderate/strong agreement). A personalised approach, using dosimetry (partition model and/or voxel-based) is recommended for activity prescription, when either whole liver or selective, non-ablative or ablative SIRT is planned (strong agreement). A mean absorbed dose to non-tumoural liver of 40 Gy or less is considered safe (strong agreement). A minimum mean target-absorbed dose to tumour of 100–120 Gy is recommended for hepatocellular carcinoma, liver metastatic colorectal cancer and cholangiocarcinoma (moderate/strong agreement). Post-SIRT imaging for treatment verification with 90Y-PET/CT is recommended (strong agreement). Post-SIRT dosimetry is also recommended (strong agreement). Conclusion Practitioners are encouraged to work towards adoption of these recommendations.


Optik ◽  
2021 ◽  
pp. 167392
Author(s):  
Jina Shim ◽  
Gyoung Min Kim ◽  
Do Young Kim ◽  
Mi Jin Yun ◽  
Soo Hyun Seo ◽  
...  

2013 ◽  
Vol 06 (01) ◽  
pp. 1250069
Author(s):  
FRANCISCO CUTANDA-HENRÍQUEZ ◽  
SILVIA VARGAS-CASTRILLÓN

Treatment planning in external beam radiation therapy (EBRT) utilizes dose volume histograms (DVHs) as optimization and evaluation tools. They present the fraction of planning target volume (PTV) receiving more than a given absorbed dose, against the absorbed dose values, and a number of radiobiological indices can be computed with their help. Equivalent uniform dose (EUD) is the absorbed dose that, uniformly imparted, would yield the same biological effect on a tumor as the dose distribution described by the DVH. Uncertainty and missing information can affect the dose distribution, therefore DVHs can be modeled as samples from a set of possible outcomes. This work studies the sensitivity of the EUD index when a small change in absorbed dose distribution takes place. EUD is treated as a functional on the set of DVHs. Defining a Lévy distance on this set and using a suitable expansion of the functional, a very simple expression for a bound on the variation of EUD when the dose distribution changes is found. This bound is easily interpreted in terms of standard treatment planning practice.


2004 ◽  
Vol 32 (1) ◽  
pp. 200-208 ◽  
Author(s):  
Ande Bao ◽  
Xia Zhao ◽  
William T. Phillips ◽  
F. Ross Woolley ◽  
Randal A. Otto ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document