scholarly journals Multicenter Trials Need To Use the Same Assay for Hepatitis C Virus Viral Load Determination

2007 ◽  
Vol 45 (11) ◽  
pp. 3788-3790 ◽  
Author(s):  
S. Laperche ◽  
F. Bouchardeau ◽  
V. Thibault ◽  
B. Pozzetto ◽  
S. Vallet ◽  
...  
2002 ◽  
Vol 103 (2) ◽  
pp. 137-143 ◽  
Author(s):  
Hideki Otagiri ◽  
Yoshihide Fukuda ◽  
Isao Nakano ◽  
Yoshiaki Katano ◽  
Hidenori Toyoda ◽  
...  

Diagnostics ◽  
2021 ◽  
Vol 11 (3) ◽  
pp. 473
Author(s):  
Fernando Velásquez-Orozco ◽  
Ariadna Rando-Segura ◽  
Joan Martínez-Camprecios ◽  
Paula Salmeron ◽  
Adrián Najarro-Centeno ◽  
...  

Diagnosis and clinical management of people infected with hepatitis C virus (HCV) relies on results from a combination of serological and virological tests. The aim of this study was to compare the performance of dried plasma spots (DPS), prepared using the cobas® Plasma Separation Card (PSC), to plasma and serum from venipuncture, for HCV diagnosis. We carried out a prospective study using DPS and paired plasma or serum samples. Serum and DPS samples were analyzed by immunoassay using Elecsys® Anti-HCV II (Roche). Plasma and DPS samples were analyzed using the cobas® HCV viral load and cobas® HCV genotyping tests (Roche). All DPS samples that had high anti-HCV antibody titers in serum were also antibody-positive, as were five of eight samples with moderate titers. Eight samples with low titers in serum were negative with DPS. Among 80 samples with plasma HCV viral loads between 61.5 and 2.2 × 108 IU/mL, 74 were RNA-positive in DPS. The mean viral load difference between plasma and DPS was 2.65 log10 IU/mL. The performance of DPS for detection of serological and virological markers of hepatitis C virus infection was comparable to that of the conventional specimen types. However, the limits of detection were higher for DPS.


2012 ◽  
Vol 2012 ◽  
pp. 1-4
Author(s):  
Takeshi Endo ◽  
Koichi Ito ◽  
Tokio Sugiura ◽  
Kenji Goto

The present patient was a 4-year-old boy. His hepatitis C virus genotype was 2a, and his viral load was high (1400,000 U/mL). The pretreatment liver biopsy revealed no fibrosis or malignancy and mild chronic hepatitis; his Knodell's histological activity (HAI) score was 4. Single nucleotide polymorphism of IL28B (rs8099917) was major type. The patient began antiviral treatment with pegylated interferon alpha 2a (90 μg/week). At week 9, serum HCV RNA became undetectable, with a sensitivity of 50 copies/mL. Antiviral treatment was discontinued at week 11 because the ALT level increased to 610 U/L. After discontinuation of therapy, the patient’s serum HCV RNA status became positive again. The serum viral load increased to 100,000 U/mL. During this period, he had been observed without medication. Sixteen months after stopping treatment, serum HCV became undetectable. Over a 4-year period, HCV RNA became negative and his anti-HCV antibody titer gradually decreased. In conclusion, though antiviral therapy resulted in failure or incomplete therapy, a reduced viral load resulted in viral clearance in the present patient. Interleukin 28B genotype might have association with the clearance of hepatitis C virus after discontinuation of antiviral therapy.


PLoS ONE ◽  
2015 ◽  
Vol 10 (9) ◽  
pp. e0138546 ◽  
Author(s):  
Cristina Cheroni ◽  
Lorena Donnici ◽  
Alessio Aghemo ◽  
Francesca Balistreri ◽  
Annalisa Bianco ◽  
...  

2012 ◽  
Vol 56 (12) ◽  
pp. 6372-6378 ◽  
Author(s):  
Jacob Lalezari ◽  
David Asmuth ◽  
Arnaldo Casiró ◽  
Hugo Vargas ◽  
Shannon Lawrence ◽  
...  

ABSTRACTIDX184 is a liver-targeted prodrug of 2′-methylguanosine (2′-MeG) monophosphate. This study investigated the safety, tolerability, antiviral activity, and pharmacokinetics of IDX184 as a single agent in treatment-naïve patients with genotype-1 chronic hepatitis C virus (HCV) infection. Forty-one patients with baseline HCV RNA ≥ 5 log10IU/ml, alanine aminotransferase (ALT) ≤ 2.5× the upper limit of normal, and compensated liver disease were dosed. Sequential cohorts of 10 patients, randomized 8:2 (active:placebo), received 25, 50, 75, and 100 mg of IDX184 once daily for 3 days, with a 14-day follow-up. There were no safety-related treatment discontinuations or serious adverse events. The adverse events and laboratory abnormalities observed for IDX184- and placebo-treated patients were similar. At the end of the 3-day treatment period, changes from baseline in HCV RNA levels (means ± standard deviations) were −0.5 ± 0.6, −0.7 ± 0.2, −0.6 ± 0.3, and −0.7 ± 0.5 log10for the 25-, 50-, 75-, and 100-mg doses, respectively, while viral load remained unchanged for the pooled placebo patients (−0.05 ± 0.3 log10). Patients with genotype-1a and patients with genotype-1b responded similarly. Serum ALT levels decreased, especially at daily doses ≥ 75 mg. During the posttreatment period, plasma viremia and serum aminotransferase levels returned to near pretreatment levels. No resistance mutations associated with IDX184 were detected. Plasma exposure of IDX184 and its nucleoside metabolite 2′-MeG was dose related and low. Changes in plasma viral load correlated with plasma exposure of 2′-MeG. In conclusion, the results from this proof-of-concept study show that small doses of the liver-targeted prodrug IDX184 were able to deliver significant antiviral activity and support further clinical evaluation of the drug candidate.


Sign in / Sign up

Export Citation Format

Share Document