scholarly journals Use of the BacT/Alert MB Mycobacterial Blood Culture System for Detection of Mycobacteria in Sterile Body Fluids Other than Blood

2008 ◽  
Vol 47 (3) ◽  
pp. 711-714 ◽  
Author(s):  
R. Mattei ◽  
A. Savarino ◽  
M. Fabbri ◽  
S. Moneta ◽  
E. Tortoli
2007 ◽  
Vol 24 (6) ◽  
pp. 1271-1277 ◽  
Author(s):  
Emel Sesli Çetin ◽  
Selçuk Kaya ◽  
Mustafa Demirci ◽  
Buket Cicioglu Aridogan

1998 ◽  
Vol 36 (11) ◽  
pp. 3273-3277 ◽  
Author(s):  
Paul Bourbeau ◽  
Julie Riley ◽  
Barbara J. Heiter ◽  
Ron Master ◽  
Carol Young ◽  
...  

Studies have demonstrated that large-volume culture methods for sterile body fluids other than blood increase recovery compared to traditional plated-medium methods. BacT/Alert is a fully automated blood culture system for detecting bacteremia and fungemia. In this study, we compared culture in BacT/Alert standard aerobic and anaerobic bottles, BacT/Alert FAN aerobic and FAN anaerobic bottles, and culture on routine media for six specimen types, i.e., continuous ambulatory peritoneal dialysate (CAPD), peritoneal, amniotic, pericardial, synovial, and pleural fluids. Specimen volumes were divided equally among the three arms of the study. A total of 1,157 specimens were tested, with 227 significant isolates recovered from 193 specimens. Recovery by method was as follows: standard bottles, 186 of 227 (82%); FAN bottles, 217 of 227 (96%); and routine culture, 184 of 227 (81%). The FAN bottles recovered significantly more gram-positive cocci (P < 0.001), Staphylococcus aureus(P = 0.003), coagulase-negative staphylococci (P = 0.008), gram-negative bacilli (P< 0.001), Enterobacteriaceae (P = 0.005), and total organisms (P < 0.001) than the routine culture. There were no significant differences in recovery between the standard bottles and the routine culture. The FAN aerobic bottle recovered significantly more gram-positive cocci (P < 0.001), S. aureus isolates (P < 0.001), coagulase-negative staphyococci (P = 0.003), and total organisms (P< 0.001) than the standard aerobic bottle, while the FAN anaerobic bottle recovered significantly more gram-positive cocci (P < 0.001), S. aureus isolates (P < 0.001), Enterobacteriaceae(P = 0.03), and total organisms (P < 0.001) than the standard anaerobic bottle. For specific specimen types, significantly more isolates were recovered from the FAN bottles compared to the routine culture for synovial (P < 0.001) and CAPD (P = 0.004) fluids. Overall, the FAN bottles were superior in performance to both the standard bottles and the routine culture for detection of microorganisms from the types of sterile body fluids included in this study.


2015 ◽  
Vol 37 (1) ◽  
pp. 23-28
Author(s):  
Soon Deok Park ◽  
Young Uh ◽  
In Ho Jang ◽  
Maria Hong ◽  
Hyeun Gyeo Lee ◽  
...  

Author(s):  
Jasmin Kaur Jasuja ◽  
Stefan Zimmermann ◽  
Irene Burckhardt

AbstractOptimisation of microbiological diagnostics in primarily sterile body fluids is required. Our objective was to apply EUCAST’s RAST on primarily sterile body fluids in blood culture bottles with total lab automation (TLA) and to compare results to our reference method Vitek2 in order to report susceptibility results earlier. Positive blood culture bottles (BACTEC™ Aerobic/Anaerobic/PEDS) inoculated with primarily sterile body fluids were semi-automatically subcultured onto Columbia 5% SB agar, chocolate agar, MacConkey agar, Schaedler/KV agar and Mueller-Hinton agar. On latter, cefoxitin, ampicillin, vancomycin, piperacillin/tazobactam, meropenem and ciprofloxacin were added. After 6 h, subcultures and RAST were imaged and MALDI-TOF MS was performed. Zone sizes were digitally measured and interpreted following RAST breakpoints for blood cultures. MIC values were determined using Vitek2 panels. During a 1-year period, 197 Staphylococcus aureus, 91 Enterococcus spp., 38 Escherichia coli, 11 Klebsiella pneumoniae and 8 Pseudomonas aeruginosa were found. Categorical agreement between RAST and MIC was 96.5%. Comparison showed no very major errors, 2/7 (28.6%) and 1/7 (14.3%) of major errors for P. aeruginosa and meropenem and ciprofloxacin, 1/9 (11.1%) for K. pneumoniae and ciprofloxacin, 4/69 (7.0%) and 3/43 (5.8%) for Enterococcus spp. and vancomycin and ampicillin, respectively. Minor errors for P. aeruginosa and meropenem (1/8; 12.8%) and for E. coli and ciprofloxacin (2/29; 6.5%) were found. 30/550 RAST measurements were within area of technical uncertainty. RAST is applicable and performs well for primarily sterile body fluids in blood culture bottles, partially better than blood-based RAST. Official EUCAST evaluation is needed.


Sign in / Sign up

Export Citation Format

Share Document