scholarly journals Comparison of Matrix-Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry and Molecular Biology Techniques for Identification of Culicoides (Diptera: Ceratopogonidae) Biting Midges in Senegal

2014 ◽  
Vol 53 (2) ◽  
pp. 410-418 ◽  
Author(s):  
Masse Sambou ◽  
Maxence Aubadie-Ladrix ◽  
Florence Fenollar ◽  
Becaye Fall ◽  
Hubert Bassene ◽  
...  

Biting midges of the genusCulicoidesare implicated as vectors for a wide variety of pathogens. The morphological identification of these arthropods may be difficult because of a lack of detailed investigation of taxonomy for this species in Africa. However, matrix-assisted laser desorption ionization−time of flight mass spectrometry (MALDI-TOF MS) profiling is efficient for arthropod identification at the species level. This study established a spectrum database ofCulicoidesspp. from Senegal using MALDI-TOF. Identification ofCulicoidesinsects to the species level before mass spectrometry was performed on the basis of morphological characters. MALDI-TOF MS reference spectra were determined for 437 field-caughtCulicoidesof 10 species. The protein profiles of all testedCulicoidesrevealed several peaks with mass ranges of 2 to 20 kDa. In a validation study, 72Culicoidesspecimens in the target species were correctly identified at the species level with a similarity of 95 to 99.9%. FourCulicoidesprotein profiles were misidentified. Nevertheless, six SuperSpectra (C. imicola,C. enderleini,C. oxystoma,C. kingi,C. magnus, andC. fulvithorax) were created. Abdomens of midges were used to amplify and sequence a portion of the mitochondrial cytochrome oxidase I gene (COI). The results obtained using the MALDI-TOF MS method were consistent with the morphological identification and similar to the genetic identification. Protein profiling using MALDI-TOF is an efficient approach for the identification ofCulicoidesspp., and it is economically advantageous for approaches that require detailed and quantitative information of vector species that are collected in field. The database of AfricanCulicoidesMS spectra created is the first database in Africa. The COI sequences of fiveCulicoidesspecies that were previously noncharacterized using molecular methods were deposited in GenBank.

2016 ◽  
Vol 54 (8) ◽  
pp. 2068-2073 ◽  
Author(s):  
Allison R. McMullen ◽  
Meghan A. Wallace ◽  
David H. Pincus ◽  
Kathy Wilkey ◽  
Carey-Ann D. Burnham

Invasive fungal infections have a high rate of morbidity and mortality, and accurate identification is necessary to guide appropriate antifungal therapy. With the increasing incidence of invasive disease attributed to filamentous fungi, rapid and accurate species-level identification of these pathogens is necessary. Traditional methods for identification of filamentous fungi can be slow and may lack resolution. Matrix-assisted laser desorption ionization–time of flight mass spectrometry (MALDI-TOF MS) has emerged as a rapid and accurate method for identification of bacteria and yeasts, but a paucity of data exists on the performance characteristics of this method for identification of filamentous fungi. The objective of our study was to evaluate the accuracy of the Vitek MS for mold identification. A total of 319 mold isolates representing 43 genera recovered from clinical specimens were evaluated. Of these isolates, 213 (66.8%) were correctly identified using the Vitek MS Knowledge Base, version 3.0 database. When a modified SARAMIS (Spectral Archive and Microbial Identification System) database was used to augment the version 3.0 Knowledge Base, 245 (76.8%) isolates were correctly identified. Unidentified isolates were subcultured for repeat testing; 71/319 (22.3%) remained unidentified. Of the unidentified isolates, 69 were not in the database. Only 3 (0.9%) isolates were misidentified by MALDI-TOF MS (includingAspergillus amoenus[n= 2] andAspergillus calidoustus[n= 1]) although 10 (3.1%) of the original phenotypic identifications were not correct. In addition, this methodology was able to accurately identify 133/144 (93.6%)Aspergillussp. isolates to the species level. MALDI-TOF MS has the potential to expedite mold identification, and misidentifications are rare.


2014 ◽  
Vol 63 (9) ◽  
pp. 1143-1147 ◽  
Author(s):  
Katherine Woods ◽  
David Beighton ◽  
John L. Klein

Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) provides rapid, accurate and cost-effective identification of a range of bacteria and is rapidly changing the face of routine diagnostic microbiology. However, certain groups of bacteria, for example streptococci (in particular viridans or non-haemolytic streptococci), are less reliably identified by this method. We studied the performance of MALDI-TOF MS for identification of the ‘Streptococcus anginosus group’ (SAG) to species level. In total, 116 stored bacteraemia isolates identified by conventional methods as belonging to the SAG were analysed by MALDI-TOF MS. Partial 16S rRNA gene sequencing, supplemented with sialidase activity testing, was performed on all isolates to provide ‘gold standard’ identification against which to compare MALDI-TOF MS performance. Overall, 100 % of isolates were correctly identified to the genus level and 93.1 % to the species level by MALDI-TOF MS. However, only 77.6 % were correctly identified to the genus level and 59.5 % to the species level by a MALDI-TOF MS direct transfer method alone. Use of a rapid in situ extraction method significantly improved identification rates when compared with the direct transfer method (P<0.001). We recommend routine use of this method to reduce the number of time-consuming full extractions required for identification of this group of bacteria by MALDI-TOF MS in the routine diagnostic laboratory. Only 22 % (1/9) of Streptococcus intermedius isolates were reliably identified by MALDI-TOF MS to the species level, even after full extraction. MALDI-TOF MS reliably identifies S. anginosus and Streptococcus constellatus to the species level but does not reliably identify S. intermedius.


2016 ◽  
Vol 10 (1) ◽  
pp. 202-208 ◽  
Author(s):  
Marisa Almuzara ◽  
Claudia Barberis ◽  
Viviana Rojas Velázquez ◽  
Maria Soledad Ramirez ◽  
Angela Famiglietti ◽  
...  

Objective:To evaluate the performance of matrix-assisted laser desorption ionization-time-of-flight mass spectrometry (MALDI-TOF MS) by using 190 Catalase-negative Gram-Positive Cocci (GPC) clinical isolates.Methods:All isolates were identified by conventional phenotypic tests following the proposed scheme by Ruoff and Christensen and MALDI-TOF MS (Bruker Daltonics, BD, Bremen, Germany). Two different extraction methods (direct transfer formic acid method on spot and ethanol formic acid extraction method) and different cut-offs for genus/specie level identification were used. The score cut-offs recommended by the manufacturer (≥ 2.000 for species-level, 1.700 to 1.999 for genus level and <1.700 no reliable identification) and lower cut-off scores (≥1.500 for genus level, ≥ 1.700 for species-level and score <1.500 no reliable identification) were considered for identification. A minimum difference of 10% between the top and next closest score was required for a different genus or species.MALDI-TOF MS identification was considered correct when the result obtained from MS database agreed with the phenotypic identification result.When both methods gave discordant results, the 16S rDNA orsodAgenes sequencing was considered as the gold standard identification method. The results obtained by MS concordant with genes sequencing, although discordant with conventional phenotyping, were considered correct. MS results discordant with 16S orsodA identification were considered incorrect.Results:Using the score cut-offs recommended by the manufacturer, 97.37% and 81.05% were correctly identified to genus and species level, respectively. On the other hand, using lower cut-off scores for identification, 97.89% and 94.21% isolates were correctly identified to genus and species level respectively by MALDI-TOF MS and no significant differences between the results obtained with two extraction methods were obtained.Conclusion:The results obtained suggest that MALDI-TOF MS has the potential of being an accurate tool for Catalase-negative GPC identification even for those species with difficult diagnosis asHelcococcus,Abiotrophia,Granulicatella, among others. Nevertheless, expansion of the library, especially including more strains with different spectra on the same species might overcome potential “intraspecies” variability problems. Moreover, a decrease of the identification scores for species and genus-level identification must be considered since it may improve the MALDI-TOF MS accuracy.


2021 ◽  
Vol 12 ◽  
Author(s):  
Keyi Yu ◽  
Zhenzhou Huang ◽  
Ying Li ◽  
Qingbo Fu ◽  
Lirong Lin ◽  
...  

Shewanella species are widely distributed in the aquatic environment and aquatic organisms. They are opportunistic human pathogens with increasing clinical infections reported in recent years. However, there is a lack of a rapid and accurate method to identify Shewanella species. We evaluated here matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) for rapid identification of Shewanella. A peptide mass reference spectra (PMRS) database was constructed for the type strains of 36 Shewanella species. The main spectrum projection (MSP) cluster dendrogram showed that the type strains of Shewanella species can be effectively distinguished according to the different MS fingerprinting. The PMRS database was validated using 125 Shewanella test strains isolated from various sources and periods; 92.8% (n = 116) of the strains were correctly identified at the species level, compared with the results of multilocus sequence analysis (MLSA), which was previously shown to be a method for identifying Shewanella at the species level. The misidentified strains (n = 9) by MALDI-TOF MS involved five species of two groups, i.e., Shewanella algae–Shewanella chilikensis–Shewanella indica and Shewanella seohaensis–Shewanella xiamenensis. We then identified and defined species-specific biomarker peaks of the 36 species using the type strains and validated these selected biomarkers using 125 test strains. Our study demonstrated that MALDI-TOF MS was a reliable and powerful tool for the rapid identification of Shewanella strains at the species level.


2017 ◽  
Vol 55 (4) ◽  
pp. 1162-1176 ◽  
Author(s):  
Andrew M. Borman ◽  
Mark Fraser ◽  
Adrien Szekely ◽  
Daniel E. Larcombe ◽  
Elizabeth M. Johnson

ABSTRACT Exophiala is a ubiquitous pleomorphic genus comprising at least 40 species, many of which have been associated with superficial, visceral, or systemic infections in humans, other mammals, or cold-blooded animals. In this study, we investigated the potential of matrix-assisted laser desorption–ionization time of flight mass spectrometry (MALDI-TOF MS) for the identification of Exophiala species. A total of 89 isolates (including 50 human and 4 animal clinical isolates) stored in the National Collection of Pathogenic Fungi were identified by PCR amplification and sequencing of internal transcribed spacer region 1. Eighty-three of the isolates corresponded to 16 known species within Exophiala/Rhinocladiella . The remaining six isolates are shown by phylogenetic analyses based on four loci to represent two novel Exophiala species. Four isolates from domestic bathrooms which form a sister species with Exophiala lecanii-corni are described here as Exophiala lavatrina sp. nov. The remaining two isolates, both from subcutaneous infections, are distantly related to Exophiala oligosperma and are described here as Exophiala campbellii sp. nov. The triazoles and terbinafine exhibited low MICs against all Exophiala isolates in vitro . MALDI-TOF MS successfully distinguished all 18 species and identified all isolates after appropriate reference spectra were created and added to commercial databases. Intraspecific mean log scores ranged from 1.786 to 2.584 and were consistently significantly higher than interspecific scores (1.193 to 1.624), with the exception of E. lecanii-corni and E. lavatrina , for which there was considerable log score overlap. In summary, MALDI-TOF MS allows the rapid and accurate identification of a wide range of clinically relevant Exophiala species.


2014 ◽  
Vol 8 (09) ◽  
pp. 1081-1088 ◽  
Author(s):  
Elena De Carolis ◽  
Antonietta Vella ◽  
Luisa Vaccaro ◽  
Riccardo Torelli ◽  
Teresa Spanu ◽  
...  

Matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF MS) has recently emerged as a powerful technique for identification of microorganisms, changing the workflow of well-established laboratories so that its impact on microbiological diagnostics has been unparalleled. In comparison with conventional identification methods that rely on biochemical tests and require long incubation procedures, MALDI-TOF MS has the advantage of identifying bacteria and fungi directly from colonies grown on culture plates in a few minutes and with simple procedures. Numerous studies on different systems available demonstrate the reliability and accuracy of the method, and new frontiers have been explored besides microbial species level identification, such as direct identification of pathogens from positive blood cultures, subtyping, and drug susceptibility detection.


2019 ◽  
Vol 43 (3) ◽  
pp. 157-162
Author(s):  
Gülşen Hasçelik ◽  
Markus Kostrzewa ◽  
Hamit Kaan Müştak ◽  
Celalettin Uner ◽  
Kadir Serdar Diker

Abstract Background The routine identification to the species level of Nocardia genus by conventional methods is a fastidious and time-consuming process owing to the limited biochemical reactivity of these microorganisms, often requiring 1 or more days to complete identification. Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) is a new technology for definitive and rapid species identification. Methods We evaluated the MALDI-TOF MS for the identification of 44 clinical isolates of Nocardia species in comparison to 16S ribosomal RNA (rRNA) gene sequencing. Nocardia isolates were identified by microbiological examination, phenotypical tests and MALDI-TOF MS and the results were compared by 16S rRNA gene sequencing. Results Of the 44 Nocardia strains, the identification of 28 isolates was determined with MALDI Biotyper database. According to this, 16 isolates (57.1%) of the strain log scores were ≥2. Two (7.1%) were identified to the species level (log scores of ≥2) as Nocardia otitidiscaviarum. The addition of a newly established Nocardia database (16 new Nocardia strains included to the original database) did significantly improve the scores. The results were 43 (97.7%) correct identification to the species level (log scores of ≥2). Conclusions This study showed that the identification of clinical Nocardia isolates by the Bruker MALDI Biotyper is highly reliable, whereas identification rates are generally lower than those for some Gram-negative bacteria and Gram-positive cocci. Based on our data, the identification rates can be improved by validated new database entries and the results can be confirmed with nucleic acid sequence analysis.


2015 ◽  
Vol 54 (2) ◽  
pp. 376-384 ◽  
Author(s):  
S. P. Buckwalter ◽  
S. L. Olson ◽  
B. J. Connelly ◽  
B. C. Lucas ◽  
A. A. Rodning ◽  
...  

The value of matrix-assisted laser desorption ionization−time of flight mass spectrometry (MALDI-TOF MS) for the identification of bacteria and yeasts is well documented in the literature. Its utility for the identification of mycobacteria andNocardiaspp. has also been reported in a limited scope. In this work, we report the specificity of MALDI-TOF MS for the identification of 162Mycobacteriumspecies and subspecies, 53Nocardiaspecies, and 13 genera (totaling 43 species) of other aerobic actinomycetes using both the MALDI-TOF MS manufacturer's supplied database(s) and a custom database generated in our laboratory. The performance of a simplified processing and extraction procedure was also evaluated, and, similar to the results in an earlier literature report, our viability studies confirmed the ability of this process to inactivateMycobacterium tuberculosisprior to analysis. Following library construction and the specificity study, the performance of MALDI-TOF MS was directly compared with that of 16S rRNA gene sequencing for the evaluation of 297 mycobacteria isolates, 148Nocardiaspecies isolates, and 61 other aerobic actinomycetes isolates under routine clinical laboratory working conditions over a 6-month period. MALDI-TOF MS is a valuable tool for the identification of these groups of organisms. Limitations in the databases and in the ability of MALDI-TOF MS to rapidly identify slowly growing mycobacteria are discussed.


Molecules ◽  
2020 ◽  
Vol 25 (20) ◽  
pp. 4775
Author(s):  
Sachio Tsuchida ◽  
Hiroshi Umemura ◽  
Tomohiro Nakayama

Mass spectrometry (MS), a core technology for proteomics and metabolomics, is currently being developed for clinical applications. The identification of microorganisms in clinical samples using matrix-assisted laser desorption/ionization–time-of-flight mass spectrometry (MALDI-TOF MS) is a representative MS-based proteomics application that is relevant to daily clinical practice. This technology has the advantages of convenience, speed, and accuracy when compared with conventional biochemical methods. MALDI-TOF MS can shorten the time used for microbial identification by about 1 day in routine workflows. Sample preparation from microbial colonies has been improved, increasing the accuracy and speed of identification. MALDI-TOF MS is also used for testing blood, cerebrospinal fluid, and urine, because it can directly identify the microorganisms in these liquid samples without prior culture or subculture. Thus, MALDI-TOF MS has the potential to improve patient prognosis and decrease the length of hospitalization and is therefore currently considered an essential tool in clinical microbiology. Furthermore, MALDI-TOF MS is currently being combined with other technologies, such as flow cytometry, to expand the scope of clinical applications.


2020 ◽  
Vol 59 (1) ◽  
pp. e02358-20
Author(s):  
Jianchun Wei ◽  
Huijuan Zhang ◽  
Huifang Zhang ◽  
Enmin Zhang ◽  
Binghua Zhang ◽  
...  

ABSTRACTThe objective of this study was to construct a rapid, high-throughput, and biosafety-compatible screening method for Bacillus anthracis and Bacillus cereus based on matrix-assisted laser desorption ionization–time of flight mass spectrometry (MALDI-TOF MS). MALDI-TOF MS coupled to ClinProTools was used to discover MALDI-TOF MS biomarker peaks and generate a classification model based on a genetic algorithm (GA) to differentiate between different Bacillus anthracis and Bacillus cereus isolates. Thirty Bacillus anthracis and 19 Bacillus cereus strains were used to construct and analyze the model, and 40 Bacillus strains were used for validation. For the GA screening model, the cross-validation values, which reflect the ability of the model to handle variability among the test spectra, and the recognition capability values, which reflect the model’s ability to correctly identify its component spectra, were all 100%. This model contained 10 biomarker peaks (m/z 3,339.9, 3,396.3, 3,682.4, 5,476.7, 6,610.6, 6,680.1, 7,365.3, 7,792.4, 9,475.8, and 10,934.1) used to correctly identify 28 Bacillus anthracis and 12 Bacillus cereus isolates from 40 Bacillus isolates, with a sensitivity and specificity of 100%. With the obvious advantages of being rapid, highly accurate, and highly sensitive and having a low cost and high throughput, MALDI-TOF MS ClinProTools is a powerful and reliable tool for screening Bacillus anthracis and Bacillus cereus strains.


Sign in / Sign up

Export Citation Format

Share Document